DC Flow Investigations in Thermoacoustic Prime Mover

Author(s):  
Richard Paridaens ◽  
Smaine Kouidri ◽  
Fathi Jebali Jerbi

In thermoacoustic device, the nonlinear phenomena are the source of secondary flows superimposed on the oscillating flow. To date, the acoustic streaming have been only characterized for progressive and standing waves in current systems. A method to characterize theoretically the secondary flows in thermoacoustic systems with more complex geometries is developed in this paper. This method is applied in the case of an annular thermoacoustic prime mover. The streaming fields are then provided. As the determination of the streaming fields requires the knowledge of the first order acoustic parameters, a linear model is used. The theoretical results of the acoustic pressure are compared to the experimental data. A relative error less than 10% is obtained, allowing the validation of the linear model.

2018 ◽  
Vol 84 (11) ◽  
pp. 74-87
Author(s):  
V. B. Bokov

A new statistical method for response steepest improvement is proposed. This method is based on an initial experiment performed on two-level factorial design and first-order statistical linear model with coded numerical factors and response variables. The factors for the runs of response steepest improvement are estimated from the data of initial experiment and determination of the conditional extremum. Confidence intervals are determined for those factors. The first-order polynomial response function fitted to the data of the initial experiment makes it possible to predict the response of the runs for response steepest improvement. The linear model of the response prediction, as well as the results of the estimation of the parameters of the linear model for the initial experiment and factors for the experiments of the steepest improvement of the response, are used when finding prediction response intervals in these experiments. Kknowledge of the prediction response intervals in the runs of steepest improvement of the response makes it possible to detect the results beyond their limits and to find the limiting values of the factors for which further runs of response steepest improvement become ineffective and a new initial experiment must be carried out.


1996 ◽  
Vol 76 (01) ◽  
pp. 005-008 ◽  
Author(s):  
Jean Claude Lormeau ◽  
Jean Pascal Herault ◽  
Jean Marc Herbert

SummaryWe examined the effect of the synthetic pentasaccharide representing the minimal binding site of heparin to antithrombin on the antithrombin-mediated inactivation of factor Vila bound to tissue factor. This effect was compared to the effect of unfractionated heparin. Using purified recombinant human coagulation factors and either a clotting or an amidolytic assay for the determination of the residual activity of factor Vila, we showed that the pentasaccharide was an efficient antithrombin-dependent inhibitor of the coagulant activity of tissue factor-factor Vila complex. In our experimental conditions, assuming a mean MW of 14,000 for heparin, the molar pseudo-first order rate constants for ATIII-mediated FVIIa inhibition by ATIII-binding heparin and by the synthetic pentasaccharide were found to be similar with respective values of 104,000 ± 10,500 min-1 and 112,000 ± 12,000 min-1 (mean ± s.e.m., n = 3)


Author(s):  
Pratik S Mehta ◽  
Pratik R. Patel ◽  
Rajesh R Parmar ◽  
M M K Modasiya ◽  
Dushyant A Shah

A novel, simple, accurate, sensitive, precise and economical derivative spectroscopic method was developed and validated for the determination of cefadroxil and probenecid in synthetic mixture. First order derivative spectroscopy method was adopted to eliminate spectral interference. The method obeys Beer’s Law in concentration ranges of 4-36 μg/ml for cefadroxil and of 5-25 μg/ml of probenecid. The zero crossing point for cefadroxil and probenecid was 260 nm and 237.8 nm respectively in 0.1N HCl. The method was validated in terms of accuracy, precision, linearity, limits of detection, limits of quantitation. This method has been successively applied to synthetic mixture and no interference from the synthetic mixture’s excipients was found.   


Sensors ◽  
2019 ◽  
Vol 19 (9) ◽  
pp. 1968 ◽  
Author(s):  
Sylvie Bilent ◽  
Thi Hong Nhung Dinh ◽  
Emile Martincic ◽  
Pierre-Yves Joubert

This paper reports on the study of microporous polydimethylsiloxane (PDMS) foams as a highly deformable dielectric material used in the composition of flexible capacitive pressure sensors dedicated to wearable use. A fabrication process allowing the porosity of the foams to be adjusted was proposed and the fabricated foams were characterized. Then, elementary capacitive pressure sensors (15 × 15 mm2 square shaped electrodes) were elaborated with fabricated foams (5 mm or 10 mm thick) and were electromechanically characterized. Since the sensor responses under load are strongly non-linear, a behavioral non-linear model (first order exponential) was proposed, adjusted to the experimental data, and used to objectively estimate the sensor performances in terms of sensitivity and measurement range. The main conclusions of this study are that the porosity of the PDMS foams can be adjusted through the sugar:PDMS volume ratio and the size of sugar crystals used to fabricate the foams. Additionally, the porosity of the foams significantly modified the sensor performances. Indeed, compared to bulk PDMS sensors of the same size, the sensitivity of porous PDMS sensors could be multiplied by a factor up to 100 (the sensitivity is 0.14 %.kPa−1 for a bulk PDMS sensor and up to 13.7 %.kPa−1 for a porous PDMS sensor of the same dimensions), while the measurement range was reduced from a factor of 2 to 3 (from 594 kPa for a bulk PDMS sensor down to between 255 and 177 kPa for a PDMS foam sensor of the same dimensions, according to the porosity). This study opens the way to the design and fabrication of wearable flexible pressure sensors with adjustable performances through the control of the porosity of the fabricated PDMS foams.


2003 ◽  
Vol 3 (1) ◽  
pp. 189-201 ◽  
Author(s):  
Ilya D. Mishev

AbstractA new mixed finite volume method for elliptic equations with tensor coefficients on rectangular meshes (2 and 3-D) is presented. The implementation of the discretization as a finite volume method for the scalar variable (“pressure”) is derived. The scheme is well suited for heterogeneous and anisotropic media because of the generalized harmonic averaging. It is shown that the method is stable and well posed. First-order error estimates are derived. The theoretical results are confirmed by the presented numerical experiments.


1. The equations of motion of viscous fluid (obtained by grafting on certain terms to the abstract equations of the Eulerian form so as to adapt these equations to the case of fluids subject to stresses depending in some hypothetical manner on the rates of distortion, which equations Navier seems to have first introduced in 1822, and which were much studied by Cauchy and Poisson) were finally shown by St. Venant and Sir Gabriel Stokes, in 1845, to involve no other assumption than that the stresses, other than that of pressure uniform in all directions, are linear functions of the rates of distortion, with a co-efficient depending on the physical state of the fluid. By obtaining a singular solution of these equations as applied to the case of pendulums in steady periodic motion, Sir G. Stokes was able to compare the theoretical results with the numerous experiments that had been recorded, with the result that the theoretical calculations agreed so closely with the experimental determinations as seemingly to prove the truth of the assumption involved. This was also the result of comparing the flow of water through uniform tubes with the flow calculated from a singular solution of the equations so long as the tubes were small and the velocities slow. On the other hand, these results, both theoretical and practical, were directly at variance with common experience as to the resistance encountered by larger bodies moving with higher velocities through water, or by water moving with greater velocities through larger tubes. This discrepancy Sir G. Stokes considered as probably resulting from eddies which rendered the actual motion other than that to which the singular solution referred and not as disproving the assumption.


Sign in / Sign up

Export Citation Format

Share Document