Modelling and Control of a Translational Robotic Arm

Author(s):  
Bin Wei

Abstract The objective of this paper is to design and model a translational robotic arm that is simple and cheap to manufacture while maintaining good functionality. Once the robotic arm is designed, the control analysis and computer simulation are conducted. When selecting the material used for the parts, the density and strength of are considered. This paper covers the design process, analysis and computer simulation of a robotic arm. The final design is a 4-DOF (degrees of freedom) pick and place robot. This robot has 1 prismatic joint and 3 revolute joints. The arm is designed to be used in multiple applications such as pick and place, car wash, chalkboard erasers, etc. Forward kinematics is used to calculate the end effectors position and orientation based on the positions of each joint. The Lagrange general method is used to come up with the equation of motion. Also, the control method selected for this robot was nonlinear decoupling PD control.

Author(s):  
Yeo Jung Yoon ◽  
Oswin G. Almeida ◽  
Aniruddha V. Shembekar ◽  
Satyandra K. Gupta

Abstract By attaching a material extrusion system to a robotic arm, we can deposit materials onto complex surfaces. Robotic manipulators can also maximize the task utility by performing other tasks such as assembly or surface polishing when they are not in use for the AM process. We present a robotic cell for embedding prefabricated components in extrusion-based AM. The robotic cell consists of two 6 degrees of freedom (DOF) robots, an extrusion system, and a gripper. One robot is used for printing a part, and the other robot takes a support role to pick and place the prefabricated component and embed it into the part being printed. After the component is embedded, AM process resumes, and the material is deposited onto the prefabricated components and previously printed layers. We illustrate the capabilities of the system by fabricating three objects.


2020 ◽  
Vol 1 (2) ◽  
pp. 35-42
Author(s):  
Norsinnira Zainul Azlan ◽  
Mubeenah Titilola Sanni ◽  
Ifrah Shahdad

This paper presents the design and development of a new low-cost pick and place anthropomorphic robotic arm for the disabled and humanoid applications. Anthropomorphic robotic arms are weapons similar in scale, appearance, and functionality to humans, and functionality. The developed robotic arm was simple, lightweight, and has four degrees of freedom (DOF) at the hand, shoulder, and elbow joints. The measurement of the link was made close to the length of the human arm. The anthropomorphic robotic arm was actuated by four DC servo motors and controlled using an Arduino UNO microcontroller board. The voice recognition unit drove the command input for the targeted object. The forward and inverse kinematics of the proposed new robotic arm has been analysed and used to program the low cost anthropomorphic robotic arm prototype to reach the desired position in the pick and place operation. This paper’s contribution is in developing the low cost, light, and straightforward weight anthropomorphic arm that can be easily attached to other applications such as a wheelchair and the kinematic study of the specific robot. The low-cost robotic arm’s capability has been tested, and the experimental results show that it can perform basic pick place tasks for the disabled and humanoid applications.


2020 ◽  
Vol 10 (20) ◽  
pp. 7146
Author(s):  
Lucas D. L. da Silva ◽  
Thiago F. Pereira ◽  
Valderi R. Q. Leithardt ◽  
Laio O. Seman ◽  
Cesar A. Zeferino

Exoskeletons are wearable mobile robots that combine various technologies to enable limb movement with greater strength and endurance, being used in several application areas, such as industry and medicine. In this context, this paper presents the development of a hybrid control method for exoskeletons, combining admission and impedance control based on electromyographic input signals. A proof of concept of a robotic arm with two degrees of freedom, mimicking the functions of a human’s upper limb, was built to evaluate the proposed control system. Through tests that measured the discrepancy between the angles of the human joint and the joint of the exoskeleton, it was possible to determine that the system remained within an acceptable error range. The average error is lower than 4.3%, and the robotic arm manages to mimic the movements of the upper limbs of a human in real-time.


The last few decades have demonstrated the benefit of fast, vast and inexpensive robots in production sectors. Robots in the industry can be cooperative or supportive to the workers. Some significant tasks such as, industrial automation, painting, welding, package loading and unloading, cutting and application specific tasks can be performed using industrial robotic arm. The aim of the project is to pick and place the objects in industries using robot arms. Z-Robot is a double arm robot. The robot arms follow the loop in a program to run the servo motors. Arduino program stores the position of each motor. When the pick command is received servo motors fixed with the robot arms start rotating based on the program and picks up the object. When the drop command is received the robot arms drops down the object. The pick and place operations can be done in any direction. End effectors connected with arm setup is used to pick and place the object.


2012 ◽  
Vol 6 (1) ◽  
pp. 5-15 ◽  
Author(s):  
Michael R Dawson ◽  
Farbod Fahimi ◽  
Jason P Carey

The objective of above-elbow myoelectric prostheses is to reestablish the functionality of missing limbs and increase the quality of life of amputees. By using electromyography (EMG) electrodes attached to the surface of the skin, amputees are able to control motors in myoelectric prostheses by voluntarily contracting the muscles of their residual limb. This work describes the development of an inexpensive myoelectric training tool (MTT) designed to help upper limb amputees learn how to use myoelectric technology in advance of receiving their actual myoelectric prosthesis. The training tool consists of a physical and simulated robotic arm, signal acquisition hardware, controller software, and a graphical user interface. The MTT improves over earlier training systems by allowing a targeted muscle reinnervation (TMR) patient to control up to two degrees of freedom simultaneously. The training tool has also been designed to function as a research prototype for novel myoelectric controllers. A preliminary experiment was performed in order to evaluate the effectiveness of the MTT as a learning tool and to identify any issues with the system. Five able-bodied participants performed a motor-learning task using the EMG controlled robotic arm with the goal of moving five balls from one box to another as quickly as possible. The results indicate that the subjects improved their skill in myoelectric control over the course of the trials. A usability survey was administered to the subjects after their trials. Results from the survey showed that the shoulder degree of freedom was the most difficult to control.


2021 ◽  
Vol 11 (13) ◽  
pp. 5865
Author(s):  
Muhammad Ahsan Gull ◽  
Mikkel Thoegersen ◽  
Stefan Hein Bengtson ◽  
Mostafa Mohammadi ◽  
Lotte N. S. Andreasen Struijk ◽  
...  

Wheelchair mounted upper limb exoskeletons offer an alternative way to support disabled individuals in their activities of daily living (ADL). Key challenges in exoskeleton technology include innovative mechanical design and implementation of a control method that can assure a safe and comfortable interaction between the human upper limb and exoskeleton. In this article, we present a mechanical design of a four degrees of freedom (DOF) wheelchair mounted upper limb exoskeleton. The design takes advantage of non-backdrivable mechanism that can hold the output position without energy consumption and provide assistance to the completely paralyzed users. Moreover, a PD-based trajectory tracking control is implemented to enhance the performance of human exoskeleton system for two different tasks. Preliminary results are provided to show the effectiveness and reliability of using the proposed design for physically disabled people.


Micromachines ◽  
2021 ◽  
Vol 12 (4) ◽  
pp. 444
Author(s):  
Guoning Si ◽  
Liangying Sun ◽  
Zhuo Zhang ◽  
Xuping Zhang

This paper presents the design, fabrication, and testing of a novel three-dimensional (3D) three-fingered electrothermal microgripper with multiple degrees of freedom (multi DOFs). Each finger of the microgripper is composed of a V-shaped electrothermal actuator providing one DOF, and a 3D U-shaped electrothermal actuator offering two DOFs in the plane perpendicular to the movement of the V-shaped actuator. As a result, each finger possesses 3D mobilities with three DOFs. Each beam of the actuators is heated externally with the polyimide film. The durability of the polyimide film is tested under different voltages. The static and dynamic properties of the finger are also tested. Experiments show that not only can the microgripper pick and place microobjects, such as micro balls and even highly deformable zebrafish embryos, but can also rotate them in 3D space.


Energies ◽  
2021 ◽  
Vol 14 (4) ◽  
pp. 1015
Author(s):  
Mingfei Huang ◽  
Yongting Deng ◽  
Hongwen Li ◽  
Jing Liu ◽  
Meng Shao ◽  
...  

This paper concentrates on a robust resonant control strategy of a permanent magnet synchronous motor (PMSM) for electric drivers with model uncertainties and external disturbances to improve the control performance of the current loop. Firstly, to reduce the torque ripple of PMSM, the resonant controller with fractional order (FO) calculus is introduced. Then, a robust two degrees-of-freedom (Robust-TDOF) control strategy was designed based on the modified resonant controller. Finally, by combining the two control methods, this study proposes an enhanced Robust-TDOF regulation method, named as the robust two degrees-of-freedom resonant controller (Robust-TDOFR), to guarantee the robustness of model uncertainty and to further improve the performance with minimized periodic torque ripples. Meanwhile, a tuning method was constructed followed by stability and robust stability analysis. Furthermore, the proposed Robust-TDOFR control method was applied in the current loop of a PMSM to suppress the periodic current harmonics caused by non-ideal factors of inverter and current measurement errors. Finally, simulations and experiments were performed to validate our control strategy. The simulation and experimental results showed that the THDs (total harmonic distortion) of phase current decreased to a level of 0.69% and 5.79% in the two testing environments.


2021 ◽  
pp. 1-9
Author(s):  
G. Perumalsamy ◽  
Deepak Kumar ◽  
Joel Jose ◽  
S. Joseph Winston ◽  
S. Murugan

Sign in / Sign up

Export Citation Format

Share Document