Analysis of Electrical Energy Savings From Daylighting Through Skylights

Solar Energy ◽  
2005 ◽  
Author(s):  
Abdelkarim Nemri ◽  
Moncef Krarti

This paper provides a simplified analysis tool to assess the energy saving potential of daylighting for commercial buildings through skylights. Specifically, the impact of daylighting is investigated for various fenestration opening sizes, glazing types, control strategies, and geographic locations. A top floor of a prototypical office building has been considered in the analysis. The results obtained for the office building can be applied to other types of buildings such as retails stores, schools, and warehouses. Based on the simulation analysis results, it was determined that skylight to floor ratio more than 0.3 does not affect significantly the lighting energy savings. An optimum value of skylight to floor area ratio was found to be 0.2 to minimize the annual total building energy use.

Author(s):  
Moncef Krarti

This paper analyzes the impact of roof covers on office building energy use for representative US climate zones. In particular, the study presented in the paper investigates the potential annual cooling energy use savings that roof covers could provide using whole-building simulation analysis to evaluate the performance of a 2-story office building in five US locations. Three parameters of the roof covers including their size, height, and transmittance, are considered in the analysis. The simulation results indicate that while roof covers had similar affects on buildings in all climate zones, their impact in reducing cooling energy usage is different and is more pronounced in cooler climates. Specifically, roof covers could potentially achieve cooling energy savings of up to: 25% in Houston, 33% in Atlanta, 31% in Nashville, 38% in Chicago, and 41% in Madison. Based on the detailed simulation analysis results, a simplified calculation model is developed to help the estimation of cooling energy savings as a function of the roof cover size, height, and transmittance.


Solar Energy ◽  
2004 ◽  
Author(s):  
Mostafa Abd El Mohimen ◽  
George Hanna ◽  
Moncef Krarti

This paper summarizes the results of a simulation analysis to determine the effectiveness of daylighting in reducing electrical energy consumption for office buildings in Egypt. Specifically, the impact on daylighting performance is investigated of window size, building size, daylighting control, and glazing type for three geographical locations in Egypt. It was determined that a window to wall area ratio of 0.20 minimizes the total annual electricity use for office buildings in three Egyptian locations, Cairo, Alexandria, and Aswan. A simplified analysis method is developed based on the analysis results to estimate the annual electrical energy savings attributed to daylighting.


Author(s):  
Khairul Rijal Wagiman ◽  
Mohd Noor Abdullah ◽  
Mohammad Yusri Hassan ◽  
Nur Hanis Mohammad Radzi

<p>Artificial lighting consumed significant amount of electrical energy in commercial buildings. Therefore, intelligent control strategies are widely implemented to reduce the lighting energy consumption. This paper presents comprehensive review of the current sensing-based strategies (i.e. occupancy, daylight and mixed), sensors placement methods (i.e. occupancy and light) and factors affecting the performance of the lighting control strategies. Based on literature survey, the sensors placement methods can be categorized into three approaches: fixed, mathematical equation and optimization. The state-of-the-art of these approaches are discusses in details. It found that, the optimization-based approach capable to find the optimal sensor placement (numbers and positions) effectively. Moreover, the mixed strategy can be produced the highest energy savings up to 95% compared with other strategies. The occupancy pattern and building characteristics are the main factors to contribute higher energy savings of sensing-based strategies in commercial buildings.  </p>


Author(s):  
Aymen Mechergui ◽  
Moncef Krarti

The paper provides the results of a simulation-based analysis to estimate the potential savings in electrical lighting energy use associated with daylighting controls using skylights for open space warehouses. First, the effectiveness of daylighting controls is investigated for several skylight opening areas, glazing types, control strategies, and several locations in Tunisia. A simplified calculation method is then developed to estimate the annual savings in electrical lighting energy use due to daylighting controls in warehouses. The simplified method has been developed and validated for several locations throughout the world.


2004 ◽  
Vol 127 (3) ◽  
pp. 366-370 ◽  
Author(s):  
Mostafa Abd El Mohimen ◽  
George Hanna ◽  
Moncef Krarti

This paper summarizes the results of a simulation analysis to determine the effectiveness of daylighting in reducing electrical energy consumption for office buildings in Egypt. Specifically, the impact on daylighting performance is investigated of window size, building size, daylighting control, and glazing type for three geographical locations in Egypt. It was determined that a window to wall area ratio of 0.20 minimizes the total annual electricity use for office buildings in three Egyptian locations, Cairo, Alexandria, and Aswan. A simplified analysis method is developed based on the analysis results to estimate the annual electrical energy savings attributed to daylighting.


2021 ◽  
Vol 13 (24) ◽  
pp. 13863
Author(s):  
Yana Akhtyrska ◽  
Franz Fuerst

This study examines the impact of energy management and productivity-enhancing measures, implemented as part of LEED Existing Buildings Operations and Management (EBOM) certification, on source energy use intensity and rental premiums of office spaces using data on four major US markets. Energy management practices, comprised of commissioning and advanced metering, may reduce energy usage. Conversely, improving air quality and occupant comfort in an effort to increase worker productivity may in turn lead to higher overall energy consumption. The willingness to pay for these features in rental office buildings is hypothesised to depend not only on the extent to which productivity gains enhance the profits of a commercial tenant but also on the lease arrangements for passing any energy savings to the tenant. We apply a difference-in-differences method at a LEED EBOM certification group level and a multi-level modelling approach with a panel data structure. The results indicate that energy management and indoor environment practices have the expected effect on energy consumption as described above. However, the magnitude of the achieved rental premiums appears to be independent of the lease type.


2021 ◽  
Author(s):  
◽  
Georgia Alexander

<p>For decades, studies have been suggesting the idea of occupancy sensors in intermittent use spaces for energy savings. This work investigates the potential energy savings of occupancy sensors in hallways, stairwells, seminar rooms and lavatories of an education building. Lighting is one of the largest consumers of energy in the building industry and these space types are often fully illuminated for long periods of vacancy. Lighting is for the user, not the building. Discussions centre around light use habits, energy saving behaviours and sensor technology such as time delay and daylight sensors. The experiment uses wireless light sensors and PIR sensors to measure light energy use and occupant use of 20 intermittent use spaces. A user survey was planned to run alongside the experiment to investigate user perceptions of changes in lighting but was discontinued due to unresolved software issues. Results of the experiment encouraged the use of occupancy sensors in intermittent use spaces. Lavatories attained highest energy saving potential 54%, seminar rooms highest annual cost savings per fitting $15.47 and highest annual energy savings 482kWh and hallways calculated the quickest payback of 8.6 years. Hallways, stairwells, seminar rooms and lavatories all offer potential for energy savings, supporting the theoretical ideas and success of occupancy sensors in intermittent use spaces.</p>


Author(s):  
N.Sujith Prasanna ◽  
Dr.J.Nagesh Kumar

Energy cost is significant in many of the manufacturing activities. The efficiency of energy use is quiet low as there are substantial visible and hidden losses. Visible losses can be easily identified and corrective action can be taken. However hidden and indirect losses form a sizeable portion of the losses. Identifying these losses is not easy and requires an integrated approach which includes thorough study of process, operations and their interactions with energy use. Industries across sectors have implemented lean management principles which target various wastes occurring in the plant. This paper discusses case studies which highlight the exploitation of lean tools as a means for unearthing hidden energy saving potential that often go unnoticed. In addition to the energy savings which results in improved profits and competitiveness, the approach also aids the industry to pursue a path of sustainable manufacturing.


2018 ◽  
Vol 164 ◽  
pp. 01007
Author(s):  
Dany Perwita Sari ◽  
Yun-shang Chiou

There are some architectural factors in the energy saving design of residential houses in Taiwan. In addition, in rural area, window glazing is a key factor to reducing electricity. For these purposes, a simulation model of exterior shading has been done in this study. Various types of shading devices have been analysed and compared in terms of energy savings. Simulation analysis by DesignBuilder reveals that shading devices has substantial impact to minimizing energy consumption. The results derived in this paper could provide useful suggestions for the shading design of residential buildings at rural area in Taiwan.


2020 ◽  
Vol 10 (12) ◽  
pp. 4336
Author(s):  
Yue Hu ◽  
Per Kvols Heiselberg ◽  
Tine Steen Larsen

A ventilated window system enhanced by phase change material (PCM) has been developed, and its energy-saving potential examined in previous works. In this paper, the ventilation control strategies are further developed, to improve the energy-saving potential of the PCM energy storage. The influence of ventilation airflow rate on the energy-saving potential of the PCM storage is firstly studied based on an EnergyPlus model of a sustainable low energy house located in New York. It shows that in summer, the optimized ventilation airflow rate is 300 m3/h. The energy-saving of utilizing a ventilated window with PCM energy storage is 10.1% compared to using a stand-alone ventilated window, and 12.0% compared to using a standard window. In winter, the optimized ventilation airflow rate is 102 m3/h. The energy-saving of utilizing a ventilated window with PCM energy storage is 26.6% compared to using a stand-alone ventilated window, and 32.8% compared to using a standard window. Based on the optimized ventilation airflow rate, a demand control ventilation strategy, which personalizes the air supply and heat pump setting based on the demand of each room, is proposed and its energy-saving potential examined. The results show that the energy savings of using demand control compared to a constant ventilation airflow rate in the house is 14.7% in summer and 30.4% in winter.