scholarly journals Demand Control Strategies of a PCM Enhanced Ventilation System for Residential Buildings

2020 ◽  
Vol 10 (12) ◽  
pp. 4336
Author(s):  
Yue Hu ◽  
Per Kvols Heiselberg ◽  
Tine Steen Larsen

A ventilated window system enhanced by phase change material (PCM) has been developed, and its energy-saving potential examined in previous works. In this paper, the ventilation control strategies are further developed, to improve the energy-saving potential of the PCM energy storage. The influence of ventilation airflow rate on the energy-saving potential of the PCM storage is firstly studied based on an EnergyPlus model of a sustainable low energy house located in New York. It shows that in summer, the optimized ventilation airflow rate is 300 m3/h. The energy-saving of utilizing a ventilated window with PCM energy storage is 10.1% compared to using a stand-alone ventilated window, and 12.0% compared to using a standard window. In winter, the optimized ventilation airflow rate is 102 m3/h. The energy-saving of utilizing a ventilated window with PCM energy storage is 26.6% compared to using a stand-alone ventilated window, and 32.8% compared to using a standard window. Based on the optimized ventilation airflow rate, a demand control ventilation strategy, which personalizes the air supply and heat pump setting based on the demand of each room, is proposed and its energy-saving potential examined. The results show that the energy savings of using demand control compared to a constant ventilation airflow rate in the house is 14.7% in summer and 30.4% in winter.

2018 ◽  
Vol 164 ◽  
pp. 01007
Author(s):  
Dany Perwita Sari ◽  
Yun-shang Chiou

There are some architectural factors in the energy saving design of residential houses in Taiwan. In addition, in rural area, window glazing is a key factor to reducing electricity. For these purposes, a simulation model of exterior shading has been done in this study. Various types of shading devices have been analysed and compared in terms of energy savings. Simulation analysis by DesignBuilder reveals that shading devices has substantial impact to minimizing energy consumption. The results derived in this paper could provide useful suggestions for the shading design of residential buildings at rural area in Taiwan.


2021 ◽  
Vol 2042 (1) ◽  
pp. 012161
Author(s):  
Yue Hu ◽  
Per Kvols Heiselberg

Abstract The paper studies the energy renovation of a residential building with new façade solutions combining smart ventilated window (VW) and PCM energy storage and the corresponding control strategy to ensure energy savings. The study is carried out by Energyplus modelling comparing the energy consumption and thermal comfort of an apartment before and after renovation. A detailed control strategy is introduced and simulated. The modelling results of the apartment before and after retrofit indicate that with the designed control strategies, the average energy saving percentage of the apartment with PCM energy storage and VW compared to the apartment without PCM energy storage and VW is 29%. The rooms with PCMVWs achieve higher energy saving than the rooms with only VWs. The PCM energy storage improves energy performance of the VWs for both heating and cooling seasons. With the renovation, the thermal comfort of all the rooms are improved for cooling season.


2021 ◽  
Vol 14 (2) ◽  
Author(s):  
Thomas Hieninger ◽  
Florian Goppelt ◽  
Ronald Schmidt-Vollus ◽  
Eberhard Schlücker

AbstractIn this paper, we present the energy-saving potential of using optimized control for centrifugal pump–driven water storages. For this purpose, a Simulink pump-pipe-storage model is used. The equations and transfer function for steady-state and transient system behavior are presented and verified. Two different control strategies—optimum constant flow rate and level guided speed control—are compared to an allegedly optimal-driven pump with constant rotational speed. Twelve centrifugal pumps between 1 and 120 kW nominal power are evaluated to analyze the influence of different system parameters. The system characteristics, which are the static head, dynamic head factor, and maximum filling head, are varied 25 times for each pump in consideration of the pump’s best efficiency point. Thus, 300 different systems are optimized for each control strategy and compared to the constant speed control. The results are analyzed and the relevant system’s parameters, which have the most significant impact on energy savings, are shown. This theoretical energy–saving potential is verified with measurements, which show the high impact of the part load losses of the frequency converter and the electric motor. A law for identifying and estimation potential energy savings is developed using this information. Four use cases are analyzed with this law. It is shown that for a cost-minimal operation, not only the savings potential but also the operating time is decisive.


Author(s):  
Branislav Ftorek ◽  
Milan Saga ◽  
Pavol Orsansky ◽  
Jan Vittek ◽  
Peter Butko

Purpose The main purpose of this paper is to evaluate the two energy saving position control strategies for AC drives valid for a wide range of boundary conditions including an analysis of their energy expenses. Design/methodology/approach For energy demands analysis, the optimal energy control based on mechanical and electrical losses minimization is compared with the near-optimal one based on symmetrical trapezoidal speed profile. Both control strategies respect prescribed maneuver time and define acceleration profile for preplanned rest-to-rest maneuver. Findings Presented simulations confirm lower total energy expenditures of energy optimal control if compared with near-optimal one, but the differences are only small due to the fact that two energy saving strategies are compared. Research limitations/implications Developed overall control system consisting of energy saving profile generator, pre-compensator and position control system respecting principles of field-oriented control is capable to track precomputed state variables precisely. Practical implications Energy demands of both control strategies are verified and compared to simulations and preliminary experiments. The possibilities of energy savings were confirmed for both control strategies. Originality/value Experimental verification of designed control structure is sufficiently promising and confirmed assumed energy savings.


2021 ◽  
Author(s):  
◽  
Georgia Alexander

<p>For decades, studies have been suggesting the idea of occupancy sensors in intermittent use spaces for energy savings. This work investigates the potential energy savings of occupancy sensors in hallways, stairwells, seminar rooms and lavatories of an education building. Lighting is one of the largest consumers of energy in the building industry and these space types are often fully illuminated for long periods of vacancy. Lighting is for the user, not the building. Discussions centre around light use habits, energy saving behaviours and sensor technology such as time delay and daylight sensors. The experiment uses wireless light sensors and PIR sensors to measure light energy use and occupant use of 20 intermittent use spaces. A user survey was planned to run alongside the experiment to investigate user perceptions of changes in lighting but was discontinued due to unresolved software issues. Results of the experiment encouraged the use of occupancy sensors in intermittent use spaces. Lavatories attained highest energy saving potential 54%, seminar rooms highest annual cost savings per fitting $15.47 and highest annual energy savings 482kWh and hallways calculated the quickest payback of 8.6 years. Hallways, stairwells, seminar rooms and lavatories all offer potential for energy savings, supporting the theoretical ideas and success of occupancy sensors in intermittent use spaces.</p>


Author(s):  
Jerzy Sowa ◽  
Maciej Mijakowski

A humidity-sensitive demand-controlled ventilation system is known for many years. It has been developed and commonly applied in regions with an oceanic climate. Some attempts were made to introduce this solution in Poland in a much severe continental climate. The article evaluates this system's performance and energy consumption applied in an 8-floor multi-unit residential building, virtual reference building described by the National Energy Conservation Agency NAPE, Poland. The simulations using the computer program CONTAM were performed for the whole hating season for Warsaw's climate. Besides passive stack ventilation that worked as a reference, two versions of humidity-sensitive demand-controlled ventilation were checked. The difference between them lies in applying the additional roof fans that convert the system to hybrid. The study confirmed that the application of demand-controlled ventilation in multi-unit residential buildings in a continental climate with warm summer (Dfb) leads to significant energy savings. However, the efforts to ensure acceptable indoor air quality require hybrid ventilation, which reduces the energy benefits. It is especially visible when primary energy use is analyzed.


2021 ◽  
Author(s):  
Christopher L. K. Wang

As sleep is unconscious, the traditional definition of thermal comfort with conscious judgment does not apply. In this thesis sleep thermal comfort is defined as the thermal condition which enables sleep to most efficiently rejuvenate the body and mind. A comfort model was developed to stimulate the respective thermal environment required to achieve the desired body thermal conditions and a new infrared sphere method was developed to measure mean radiant temperature. Existing heating conditions according to building code conditions during sleeping hours was calculated to likely overheat a sleeping person and allowed energy saving potential by reducing nighttime heating set points. Experimenting with existing radiantly and forced air heated residential buildings, it was confirmed that thermal environment was too hot for comfortable sleep and that the infrared sphere method shows promise. With the site data, potential energy savings were calculated and around 10% of energy consumption reduction may be achieved during peak heating.


Author(s):  
N.Sujith Prasanna ◽  
Dr.J.Nagesh Kumar

Energy cost is significant in many of the manufacturing activities. The efficiency of energy use is quiet low as there are substantial visible and hidden losses. Visible losses can be easily identified and corrective action can be taken. However hidden and indirect losses form a sizeable portion of the losses. Identifying these losses is not easy and requires an integrated approach which includes thorough study of process, operations and their interactions with energy use. Industries across sectors have implemented lean management principles which target various wastes occurring in the plant. This paper discusses case studies which highlight the exploitation of lean tools as a means for unearthing hidden energy saving potential that often go unnoticed. In addition to the energy savings which results in improved profits and competitiveness, the approach also aids the industry to pursue a path of sustainable manufacturing.


2016 ◽  
Vol 41 (1) ◽  
pp. 88-92
Author(s):  
Rong-Yue Zheng ◽  
Jian Yao

A large number of residential buildings in hot summer and cold winter zone of China are non-energy efficient with poor indoor thermal conditions. Retrofitting residential buildings with energy efficiency measures is thus important for residents. However, this work progressed slowly because practically applicable measures that not only have high energy savings but also improve indoor thermal performance have not been studied. Thus, this paper carried out a simulation study on the selection of suitable energy saving measures for residential buildings in hot summer and cold winter zone of China. Five potential energy saving options are considered and the energy, indoor thermal comfort and economic performance are compared. The results show that adding movable solar shades is the optimum option with all performance indices ranking first. Meanwhile, this measure is also the only acceptable energy saving solution for residents since its payback period is less than the lifespan of a building. As a conclusion, it is recommended to use movable solar shades as a first priority when retrofitting residential buildings.


Sign in / Sign up

Export Citation Format

Share Document