Challenges in Designing and Building a 700 MW All-Air-Cooled Steam Electric Power Plant

Author(s):  
John T. Langaker ◽  
Christopher Hamker ◽  
Ralph Wyndrum

Large natural gas fired combined cycle electric power plants, while being an increasingly efficient and cost effective technology, are traditionally large consumers of water resources, while also discharging cooling tower blowdown at a similar rate. Water use is mostly attributed to the heat rejection needs of the gas turbine generator, the steam turbine generator, and the steam cycle condenser. Cooling with air, i.e. dry cooling, instead of water can virtually eliminate the environmental impact associated with water usage. Commissioned in the fall of 2010 with this in mind, the Halton Hills Generating Station located in the Greater Toronto West Area, Ontario, Canada, is a nominally-rated 700 Megawatt combined cycle electric generating station that is 100 percent cooled using various air-cooled heat exchangers. The resulting water consumption and wastewater discharge of this power plant is significantly less than comparably sized electric generating plants that derive cooling from wet methods (i.e, evaporative cooling towers). To incorporate dry cooling into such a power plant, it is necessary to consider several factors that play important roles both during plant design as well as construction and commissioning of the plant equipment, including the dry cooling systems. From the beginning a power plant general arrangement and space must account for dry cooling’s increase plot area requirements; constraints therein may render air cooling an impossible solution. Second, air cooling dictates specific parameters of major and auxiliary equipment operation that must be understood and coordinated upon purchase of such equipment. Until recently traditional wet cooling has driven standard designs, which now, in light of dry cooling’s increase in use, must be re-evaluated in full prior to purchase. Lastly, the construction and commissioning of air-cooling plant equipment is a significant effort which demands good planning and execution.

2010 ◽  
Vol 132 (12) ◽  
pp. 57-57
Author(s):  
Lee S. Langston

This article presents an overview of gas turbine combined cycle (CCGT) power plants. Modern CCGT power plants are producing electric power as high as half a gigawatt with thermal efficiencies approaching the 60% mark. In a CCGT power plant, the gas turbine is the key player, driving an electrical generator. Heat from the hot gas turbine exhaust is recovered in a heat recovery steam generator, to generate steam, which drives a steam turbine to generate more electrical power. Thus, it is a combined power plant burning one unit of fuel to supply two sources of electrical power. Most of these CCGT plants burn natural gas, which has the lowest carbon content of any other hydrocarbon fuel. Their near 60% thermal efficiencies lower fuel costs by almost half compared to other gas-fired power plants. Their installed capital cost is the lowest in the electric power industry. Moreover, environmental permits, necessary for new plant construction, are much easier to obtain for CCGT power plants.


1995 ◽  
Vol 117 (4) ◽  
pp. 713-723 ◽  
Author(s):  
D. M. Leis ◽  
M. J. Boss ◽  
M. P. Melsert

The Medway Project is a 660 MW combined cycle power plant, which employs two of the world’s largest advanced technology MS9001FA combustion turbine generators and an advanced design reheat steam turbine generator in a power plant system designed for high reliability and efficiency. This paper discusses the power plant system optimization and design, including thermodynamic cycle selection, equipment arrangement, and system operation. The design of the MS9001FA combustion turbine generator and the steam turbine generator, including tailoring for the specific application conditions, is discussed.


Author(s):  
Hiroyuki Yamazaki ◽  
Yoshiaki Nishimura ◽  
Masahiro Abe ◽  
Kazumasa Takata ◽  
Satoshi Hada ◽  
...  

Tohoku Electric Power Company, Inc. (Tohoku-EPCO) has been adopting cutting-edge gas turbines for gas turbine combined cycle (GTCC) power plants to contribute for reduction of energy consumption, and making a continuous effort to study the next generation gas turbines to further improve GTCC power plants efficiency and flexibility. Tohoku-EPCO and Mitsubishi Hitachi Power Systems, Ltd (MHPS) developed “forced air cooling system” as a brand-new combustor cooling system for the next generation GTCC system in a collaborative project. The forced air cooling system can be applied to gas turbines with a turbine inlet temperature (TIT) of 1600deg.C or more by controlling the cooling air temperature and the amount of cooling air. Recently, the forced air cooling system verification test has been completed successfully at a demonstration power plant located within MHPS Takasago Works (T-point). Since the forced air cooling system has been verified, the 1650deg.C class next generation GTCC power plant with the forced air cooling system is now being developed. Final confirmation test of 1650deg.C class next generation GTCC system will be carried out in 2020.


Author(s):  
M. D. Duran ◽  
A. Rovira

It is the purpose of this work to show how to select the best configuration as a function of the combined cycle power. It uses thermo-economic optimization technique based on flexible genetic algorithms (GA). These results will be based on a Thermoeconomic model developed in previous works, this maximizes the cash flow by choosing the correct parameters for the plant design — particularly those corresponding to the HRSG — subject to the restriction that hypothetical, but realistic turbines have already been chosen. This study begins with an analysis of the trends in the commercial gas turbines (GT) design. It was observed that in spite of the diverse companies, the design parameters as well as the turbine cost, follow certain trends depending on the turbine power. When a CCGT power plant is planned, once the GT is selected, is necessary to determine which configuration of the HRSG is the most appropriate in order to get the maximum performance and the best economical results. There is a wide variety of selections of CCGT power plants configurations. To facilitate the analysis of this ample number of CCGT systems we will apply our study to the following types of HRSG: Double pressure with and without reheater, Triple pressure levels with reheater and Triple pressure levels with reheater and supercritical pressure. As a result of this study it may be observed that some design trends should be established so as to decide which configuration (including supercritical cycles) is better to select to specific power.


Author(s):  
Günnur Şen ◽  
Mustafa Nil ◽  
Hayati Mamur ◽  
Halit Doğan ◽  
Mustafa Karamolla ◽  
...  

Natural gas combined cycle power plants (CCPPs) are widely used to meet peak loads in electric energy production. Continuous monitoring of the output electrical power of CCPPs is a requirement for power performance. In this study, the role of ambient temperature change having the greatest effect on electric production is investigated for a natural gas CCPP. The plant has generated electricity for fourteen years and setup at 240 MW in Aliağa, İzmir, Turkey. Depending on the seasonal temperature changes, the study data were obtained from each gas turbine (GT), steam turbine (ST) and combined cycle blocks (CCBs) in the ambient temperature range of 8-23°C. It has been found that decreases of the electric energy in the GTs because of the temperature increase and indirectly diminishes of the electricity production in the STs. As a result, the efficiency of each GT, ST and CCB reduced, although the quantity of fuel consumed by the controllers in the plant was decreased. As a result of this data, it has been recommended and applied that additional precautions have been taken for the power plant to bring the air entering the combustion chamber to ideal conditions and necessary air cooling systems have been installed.


Author(s):  
J. P. Zanyk

A review of the development and use of the gas turbine generator unit in The Dow Chemical Company for the cogeneration of steam and electric power energy for Dow’s major chemical complex. This review highlights the success and problems of Dow Chemical’s most recently constructed power plant at its Texas Division in Freeport, Texas. A review of Dow’s experience and developed technology to provide a reliable cogenerating plant.


Author(s):  
J. Fleury

An ammonia bottoming cycle is under active development at Electricité de France. To be implemented in a nuclear power plant downstream from the steam cycle, shortened for this application, its purpose is to make it possible to practice air cooling in satisfactory economic conditions. After an analysis of the main parameters of the bottoming cycle (H2O/NH3) (i.e., back pressure and temperature differences in the heat exchangers) its advantages are enumerated: in addition to those the dry cooling concept, the major benefit consists of the fact that the bottoming cycle makes use of low atmospheric temperatures in winter, producing a significant increase in the power output, just when it is most needed in many geographic locations. Emphasis is placed on the experimental work performed on E.D.F. test facilities and the construction of a 20-MWe demonstration bottoming cycle power plant at Gennevilliers power station. A brief account is given of test results and experimental programs.


Author(s):  
Geoffrey Short ◽  
Addison K. Stark ◽  
Daniel Matuszak ◽  
James F. Klausner

Fresh water withdrawal for thermoelectric power generation in the U.S. is approximately 139 billion gallons per day (BGD), or 41% of total fresh water draw, making it the largest single use of fresh water in the U.S. Of the fresh water withdrawn for the power generation sector, 4.3 BGD is dissipated to the atmosphere by cooling towers and spray ponds. Dry-cooled power plants are attractive and sometimes necessary because they avoid significant withdrawal and consumption of freshwater resources that could otherwise be used for other purposes. This could become even more important when considering the potential effects of climate change (1). Additional benefits of dry-cooling include power plant site flexibility, reduced risk of water scarcity, and faster permitting (reducing project development time and cost). However, dry-cooling systems are known to be more costly and larger than their wet-cooling counterparts. Additionally, without the benefit of additional latent heat transfer through evaporation, the Rankine cycle condensing (cold) temperature for dry-cooling is typically higher than that for wet-cooling, affecting the efficiency of power production and the resultant levelized cost of electricity (LCOE). The Advanced Research Projects Agency - Energy (ARPA-E) has developed a technoeconomic analysis (TEA) model for the development of indirect dry-cooling systems employing steam condensation within a natural gas combined cycle power plant. The TEA model has been used to inform the Advanced Research in Dry-Cooling (ARID) Program on the performance metrics needed to achieve an economical dry-cooling technology. In order to assess the relationship between air-cooled heat exchanger (ACHX) performance, including air side heat transfer coefficient and pressure drop, and power plant economics, ARPA-E has employed a modified version of the National Energy Technology Laboratory (NETL) model of a 550 MW natural gas combined cycle (NGCC) plant employing an evaporative cooling system. The evaporative cooling system, including associated balance of system costs, was replaced with a thermodynamic model for an ACHX with the desired improved heat transfer performance and supplemental cooling and storage systems. Monte Carlo simulation determined an optimal ACHX geometry and associated ACHX cost. Allowing for an increase in LCOE of 5%, the maximum allowable additional cost of the supplemental cooling system was determined as a function of the degree of cooling of the working fluid required. This paper describes the methodologies employed in the TEA, details the results, and includes related models as supplemental material, while providing insight on how the open source tool might be used for thermal management innovation.


Sign in / Sign up

Export Citation Format

Share Document