Analysis of a Hybrid PEMFC-SOFC Gas Turbine Power Plant

Author(s):  
Mohamed Gadalla ◽  
Nabil Al Aid

In this study, a complete economic analysis of integrating different types of fuel cells in Gas Turbine power plants is conducted. The paper investigates the performance of a hybrid system that comprises of a SOFC (Solid-Oxide-Fuel-Cell), a PEMFC (polymer electrolyte membrane fuel Cell), and SOFC-PEMFC which is/are integrated into a Gas Turbine power plant. Detailed modeling, thermodynamic, kinetic, geometric models are developed, implemented and validated for the synthesis/design and operational analysis of the combined hybrid system. The economic analysis is considered to be the basic concepts for thermo-economic optimization of the power plant under investigation, with the aim of finding the optimum set of design/operating parameters. Moreover, one of the aims of this paper is to present a detailed economic analysis of a highly coupled PEMFC-SOFC–GT hybrid plant, paying special attention to the sources of inefficiency and analyzing their variations with respect to changes in their operational parameters.

Author(s):  
Denver Cheddie ◽  
Renique Murray

Power generation using gas turbine power plants operating on the Brayton cycle suffers from low efficiencies and high irreversibilities. In this work, a solid oxide fuel cell (SOFC) is proposed for integration into a 10 MW gas turbine power plant, operating at 30% electrical efficiency (13.7% second law efficiency). The SOFC system entails anode recycling to enable self sustaining reformation reactions, thus alleviating the need for an external water supply and steam generation unit. It also utilizes turbine outlet heat recovery to ensure a sufficiently high SOFC operating temperature. The power output of the hybrid plant is 26.2 MW at 63.4% efficiency (35.3% second law efficiency). The hybrid plant performs best when 70–80% anode recycling is used. A thermo-economic model predicts a payback period of 4.6 years, based on future projected SOFC cost estimates.


2021 ◽  
Vol 286 ◽  
pp. 04013
Author(s):  
George Iulian Balan ◽  
Octavian Narcis Volintiru ◽  
Ionut Cristian Scurtu ◽  
Florin Ioniță ◽  
Mirela Letitia Vasile ◽  
...  

Vessels that have navigation routes in areas with ambient temperatures that can drop below + 5 [°C], with a relative humidity of over 65%, will have implemented technical solutions for monitoring and combating ice accumulations in the intake routes of gas turbine power plants. Because gas turbines are not designed and built to allow the admission of foreign objects (in this case - ice), it is necessary to avoid the accumulation of ice through anti-icing systems and not to melt ice through defrost systems. Naval anti-icing systems may have as a source of energy flow compressed air, supersaturated steam, exhaust gases, electricity or a combination of those listed. The monitoring and optimization of the operation of the anti-icing system gives the gas turbine power plant an operation as close as possible to the normal regimes stipulated in the ship's construction or retrofit specification.


Author(s):  
Alberto Vannoni ◽  
Andrea Giugno ◽  
Alessandro Sorce

Abstract Renewable energy penetration is growing, due to the target of greenhouse-gas-emission reduction, even though fossil fuel-based technologies are still necessary in the current energy market scenario to provide reliable back-up power to stabilize the grid. Nevertheless, currently, an investment in such a kind of power plant might not be profitable enough, since some energy policies have led to a general decrease of both the average price of electricity and its variability; moreover, in several countries negative prices are reached on some sunny or windy days. Within this context, Combined Heat and Power systems appear not just as a fuel-efficient way to fulfill local thermal demand, but also as a sustainable way to maintain installed capacity able to support electricity grid reliability. Innovative solutions to increase both the efficiency and flexibility of those power plants, as well as careful evaluations of the economic context, are essential to ensure the sustainability of the economic investment in a fast-paced changing energy field. This study aims to evaluate the economic viability and environmental impact of an integrated solution of a cogenerative combined cycle gas turbine power plant with a flue gas condensing heat pump. Considering capital expenditure, heat demand, electricity price and its fluctuations during the whole system life, the sustainability of the investment is evaluated taking into account the uncertainties of economic scenarios and benchmarked against the integration of a cogenerative combined cycle gas turbine power plant with a Heat-Only Boiler.


Author(s):  
Mohamed Gadalla ◽  
Nabil Al Aid

The purpose of this paper is to conduct a complete comparative, energy and 2nd low analyses between different types of fuel cells integrated with a gas turbine power plant. Different levels of modeling for the solid oxide fuel cell (SOFC), the proton exchange membrane fuel cell (PEMFC) and the integrated systems are to be presented. The overall system performance is analyzed by employing individual models and further applying energy and exergetic analyses for different configurations of gas turbine power cycles. The study includes applying different proposed methods and techniques to enhance the overall efficiency of the integrated cycle. After performing the complete technical management of the complete system, a comparative study between conventional and PEMFC and SOFC cycles is investigated to highlight the corresponding advantages and disadvantages of each system. The following systems are tested and evaluated: (a) Conventional Gas Turbine System with a combustion Chamber (b) Integrated SOFC Stack into a Gas Turbine System (c) The Proposed Integrated System with both SOFC and PEMFC.


Author(s):  
Lorenzo Dambrosio ◽  
Marco Bomba ◽  
Sergio M. Camporeale ◽  
Bernardo Fortunato

A diagnostic tool able to detect faults that may occur in a gas turbine power plant at an early stage of their emergence is of a great importance for power production. In the present paper, a diagnostic tool, based on Feed Forward Neural Networks (FFNN), has been proposed for gas turbine power plants with a condition monitoring approach. The main aim of the proposed diagnostic tool is to reliably detect not only every considered single fault, but also two or more faults that may occur contemporarily. Two different FFNNs compose the proposed diagnostic tool. The first network, that is not-fully connected, operates a fault pre-processing in order to evaluate the influence of the single fault variable on the single fault condition. The second FFNN detects the fault conditions by means of an iterative process. Such a diagnostic tool has been applied to a mathematical model of a single shaft gas turbine for power generation, resulting able to detect the 100% of single faults and the 80% of combined faults.


Author(s):  
Wei Jiang ◽  
Ruxian Fang ◽  
Jamil A. Khan ◽  
Roger A. Dougal

Fuel Cell is widely regarded as a potential alternative in the electric utility due to its distinct advantages of high energy conversion efficiency, low environmental impact and flexible uses of fuel types. In this paper we demonstrate the enhancement of thermal efficiency and power density of the power plant system by incorporating a hybrid cycle of Solid Oxide Fuel Cell (SOFC) and gas turbine with appropriate configurations. In this paper, a hybrid system composed of SOFC, gas turbine, compressor and high temperature heat exchanger is developed and simulated in the Virtual Test Bed (VTB) computational environment. The one-dimensional tubular SOFC model is based on the electrochemical and thermal modeling, accounting for the voltage losses and temperature dynamics. The single cell is discretized using a finite volume method where all the governing equations are solved for each finite volume. Simulation results show that the SOFC-GT hybrid system could achieve a 70% total electrical efficiency (LHV) and an electrical power output of 853KW, around 30% of which is produced by the power turbine. Two conventional power plant systems, i.e. gas turbine recuperative cycle and pure Fuel Cell power cycle, are also simulated for the performance comparison to validate the improved performance of Fuel Cell/Gas Turbine hybrid system. Finally, the dynamic behavior of the hybrid system is presented and analyzed based on the system simulation.


2014 ◽  
Vol 79 ◽  
pp. 431-440 ◽  
Author(s):  
S.O. Oyedepo ◽  
R.O. Fagbenle ◽  
S.S. Adefila ◽  
S.A. Adavbiele

Author(s):  
Henry Egware ◽  
Albert I. Obanor ◽  
Harrison Itoje

Energy and exergy analyses were carried out on an active 42MW open cycle gas turbine power plant. Data from the power plant record book were employed in the investigation. The First and Second Laws of Thermodynamics were applied to each component of the gas power plant at ambient air temperature range of 21 - 330C. Results obtained from the analyses show that the energy and exergy efficiencies decrease with increase in ambient air temperature entering the compressor. It was also shown that 66.98% of fuel input and 54.53% of chemical exergy are both lost to the environment as heat from the combustion chamber in the energy and exergy analysis respectively. The energy analysis quantified the efficiency of the plant arising from energy losses , while exergy analysis revealed the magnitude of losses in various components of the plant. Therefore a complete thermodynamic evaluation of gas turbine power plants requires the use of both analytical methods.


Sign in / Sign up

Export Citation Format

Share Document