X-ray CCD camera to detect scattered light in the experimental chamber of the ALOISA beamline

Author(s):  
Emanuele Pace ◽  
Giampiero Naletto
Author(s):  
James F. Mancuso ◽  
William B. Maxwell ◽  
Russell E. Camp ◽  
Mark H. Ellisman

The imaging requirements for 1000 line CCD camera systems include resolution, sensitivity, and field of view. In electronic camera systems these characteristics are determined primarily by the performance of the electro-optic interface. This component converts the electron image into a light image which is ultimately received by a camera sensor.Light production in the interface occurs when high energy electrons strike a phosphor or scintillator. Resolution is limited by electron scattering and absorption. For a constant resolution, more energy deposition occurs in denser phosphors (Figure 1). In this respect, high density x-ray phosphors such as Gd2O2S are better than ZnS based cathode ray tube phosphors. Scintillating fiber optics can be used instead of a discrete phosphor layer. The resolution of scintillating fiber optics that are used in x-ray imaging exceed 20 1p/mm and can be made very large. An example of a digital TEM image using a scintillating fiber optic plate is shown in Figure 2.


2001 ◽  
Vol 66 (6) ◽  
pp. 973-982 ◽  
Author(s):  
Čestmír Koňák ◽  
Jaroslav Holoubek ◽  
Petr Štěpánek

A time-resolved small-angle light scattering apparatus equipped with azimuthal integration by means of a conical lens or software analysis of scattering patterns detected with a CCD camera was developed. Averaging allows a significant reduction of the signal-to-noise ratio of scattered light and makes this technique suitable for investigation of phase separation kinetics. Examples of applications to time evolution of phase separation in concentrated statistical copolymer solutions and dissolution of phase-separated domains in polymer blends are given.


Author(s):  
Ogün Baris Tapar ◽  
Jérémy Epp ◽  
Matthias Steinbacher ◽  
Jens Gibmeier

AbstractAn experimental heat treatment chamber and control system were developed to perform in-situ X-ray diffraction experiments during low-pressure carburizing (LPC) processes. Results from the experimental chamber and industrial furnace were compared, and it was proven that the built system is reliable for LPC experiments. In-situ X-ray diffraction investigations during LPC treatment were conducted at the German Electron Synchrotron Facility in Hamburg Germany. During the boost steps, carbon accumulation and carbide formation was observed at the surface. These accumulation and carbide formation decelerated the further carbon diffusion from atmosphere to the sample. In the early minutes of the diffusion steps, it is observed that cementite content continue to increase although there is no presence of gas. This effect is attributed to the high carbon accumulation at the surface during boost steps which acts as a carbon supply. During quenching, martensite at higher temperature had a lower c/a ratio than later formed ones. This difference is credited to the early transformation of austenite regions having lower carbon content. Also, it was noticed that the final carbon content dissolved in martensite reduced compared to carbon in austenite before quenching. This reduction was attributed to the auto-tempering effect.


1998 ◽  
Vol 5 (3) ◽  
pp. 642-644 ◽  
Author(s):  
J. Y. Huang ◽  
I. S. Ko

A diagnostic beamline is being constructed in the PLS storage ring for measurement of electron- and photon-beam properties. It consists of two 1:1 imaging systems: a visible-light imaging system and a soft X-ray imaging system. In the visible-light imaging system, the transverse beam size and beam position are measured with various detectors: a CCD camera, two photodiode arrays and a photon-beam position monitor. Longitudinal bunch structure is also investigated with a fast photodiode detector and a picosecond streak camera. On the other hand, the soft X-ray imaging system is under construction to measure beam sizes with negligible diffraction-limited error. The X-ray image optics consist of a flat cooled mirror and two spherical focusing mirrors.


2017 ◽  
Vol 6 (1) ◽  
pp. 93-101 ◽  
Author(s):  
Philipp Hoelzmann ◽  
Torsten Klein ◽  
Frank Kutz ◽  
Brigitta Schütt

Abstract. Portable energy-dispersive X-ray fluorescence spectrometers (p-ED-XRF) have become increasingly popular in sedimentary laboratories to quantify the chemical composition of a range of materials such as sediments, soils, solid samples, and artefacts. Here, we introduce a low-cost, clearly arranged unit that functions as a sample chamber (German industrial property rights no. 20 2014 106 048.0) for p-ED-XRF devices to facilitate economic, non-destructive, fast, and semi-continuous analysis of (sediment) cores or other solid samples. The spatial resolution of the measurements is limited to the specifications of the applied p-ED-XRF device – in our case a Thermo Scientific Niton XL3t p-ED-XRF spectrometer with a maximum spatial resolution of 0.3 cm and equipped with a charge-coupled device (CCD) camera to document the measurement spot. We demonstrate the strength of combining p-ED-XRF analyses with this new sample chamber to identify Holocene facies changes (e.g. marine vs. terrestrial sedimentary facies) using a sediment core from an estuarine environment in the context of a geoarchaeological investigation at the Atlantic coast of southern Spain.


2002 ◽  
Author(s):  
Emi Miyata ◽  
Chikara Natsukari ◽  
Tomoyuki Kamazuka ◽  
Hirohiko Kouno ◽  
Hiroshi Tsunemi ◽  
...  

2009 ◽  
Vol 56 (3) ◽  
pp. 747-751 ◽  
Author(s):  
Hiroshi Nakajima ◽  
Daisuke Matsuura ◽  
Naohisa Anabuki ◽  
Emi Miyata ◽  
Hiroshi Tsunemi ◽  
...  

2020 ◽  
Vol 10 (7) ◽  
pp. 2611
Author(s):  
Hirokatsu Yumoto ◽  
Yuichi Inubushi ◽  
Taito Osaka ◽  
Ichiro Inoue ◽  
Takahisa Koyama ◽  
...  

A nanofocusing optical system—referred to as 100 exa—for an X-ray free-electron laser (XFEL) was developed to generate an extremely high intensity of 100 EW/cm2 (1020 W/cm2) using total reflection mirrors. The system is based on Kirkpatrick-Baez geometry, with 250-mm-long elliptically figured mirrors optimized for the SPring-8 Angstrom Compact Free-Electron Laser (SACLA) XFEL facility. The nano-precision surface employed is coated with rhodium and offers a high reflectivity of 80%, with a photon energy of up to 12 keV, under total reflection conditions. Incident X-rays on the optics are reflected with a large spatial acceptance of over 900 μm. The focused beam is 210 nm × 120 nm (full width at half maximum) and was evaluated at a photon energy of 10 keV. The optics developed for 100 exa efficiently achieved an intensity of 1 × 1020 W/cm2 with a pulse duration of 7 fs and a pulse energy of 150 μJ (25% of the pulse energy generated at the light source). The experimental chamber, which can provide different stage arrangements and sample conditions, including vacuum environments and atmospheric-pressure helium, was set up with the focusing optics to meet the experimental requirements.


1997 ◽  
Vol 3 (S2) ◽  
pp. 1125-1126
Author(s):  
S.J. Pan ◽  
A. Shih ◽  
W.S. Liou ◽  
M.S. Park ◽  
G. Wang ◽  
...  

An experimental X-ray cone-beam microtomographic imaging system utilizing a generalized Feldkamp reconstruction algorithm has been developed in our laboratory. This microtomographic imaging system consists of a conventional dental X-ray source (Aztech 65, Boulder, CO), a sample position and rotation stage, an X-ray scintillation phosphor screen, and a high resolution slow scan cooled CCD camera (Kodak KAF 1400). A generalized Feldkamp cone-beam algorithm was used to perform tomographic reconstruction from cone-beam projection data. This algorithm was developed for various hardware configuration to perform reconstruction of spherical, rod-shaped and plate-like specimen.A test sample consists of 8 glass beads (approx. 800μm in diameter) dispersed in an epoxy-filled #0 gelatin capsule. One hundred X-ray projection images were captured equal angularly (at 3.6 degree spacing) by the cooled CCD camera at a of 1317×967 (17×17mm2) pixels with 12-bit dynamic range. Figure 1 shows a 3D isosurface rendering of the test sample. The eight glass beads and trapped air bubbles (arrows) in the epoxy resin (e) are clearly visible.


1997 ◽  
Vol 159 ◽  
pp. 427-428
Author(s):  
Y. Zhao ◽  
J. Zhong ◽  
J. Wei ◽  
J. Hu ◽  
Q. Li

AbstractWe used the CCD camera and spectrograph of the 2.16-m telescope of Beijing Astronomical Observatory to identify the ROSAT All-Sky survey sources in two 2° Ü 2° fields. Of a total of 16 X-ray sources, we identified 13 of them as follows: two QSOs, two Seyfert galaxies, two active galaxies, two clusters of galaxies, and five late-type stars. Three X-ray sources remained unidentified.


Sign in / Sign up

Export Citation Format

Share Document