scholarly journals Low-power vertical cavity NAND gate

Author(s):  
A. Hurtado ◽  
A. P. Gonzalez-Marcos ◽  
J. A. Martin-Pereda
Keyword(s):  
2014 ◽  
Vol 26 (10) ◽  
pp. 1003-1006 ◽  
Author(s):  
Mong-Kai Wu ◽  
Michael Liu ◽  
Rohan Bambery ◽  
Milton Feng ◽  
Nick Holonyak

Author(s):  
Y. A. Akulova ◽  
B. J. Thibeault ◽  
J. C. Ko ◽  
E. Goobar ◽  
L. A. Coldren

2011 ◽  
Vol 9 (5) ◽  
pp. 051401-51403 ◽  
Author(s):  
马雅男 Yanan Ma ◽  
罗斌 Bin Luo ◽  
闫连山 Lianshan Yan ◽  
潘炜 Wei Pan ◽  
邹喜华 Xihua Zou ◽  
...  

2018 ◽  
Vol 7 (1) ◽  
pp. 106
Author(s):  
U. Saravanakumar ◽  
P Suresh ◽  
S.P Vimal

The routers in Network on Chips (NoCs) are used to transmit the data among the Processing Elements (PEs) in the field, and it can be done through transmission links between the routers. Traditionally, the data transmission between the PEs of NoC is carried out by the parallel bus which consumes more power, leads to be complex routing strategies and occupies more area within the field. Instead of parallel bus, serializes and deserialisers are used for serial data transmission, which consumes very less power and area than traditional method. To implement serialiser-deserialiser at the transceiver in the router for on chip communication, a three-level encoding technique is implemented in this design, which eliminates power hungry blocks in earlier works, such as Phase Locked Loops, Feed Forward Equalizers, Decision Feedback Equalizers and the repeaters along the transmission line. In this paper, a low-power transceiver is proposed using modified C2MOS flip flop and Dynamic TGMS flip flop circuits in order to minimize the delay. The power reduction of 35.683% and the delay reduction of 44.71% were achieved in the proposed transceiver than the NAND gate based D flip flop transceivers.


2005 ◽  
Vol 22 (8) ◽  
pp. 1219-1224 ◽  
Author(s):  
M. E. Paige

Abstract A vertical cavity laser hygrometer has been developed for balloon-borne measurements. This hygrometer meets many of the specifications that are required for common weather balloon instrumentation, including weight, size, time response, and sensitivity. In addition, the system cost has been dramatically lowered relative to prior diode laser instruments. Sensitivity of 2 and 0.9 μbar at low- and high-altitude conditions, respectively, has been obtained in a 1-s measurement period, with the strong possibility of improved performance in the near future. The engineering advances that are demonstrated by this system make balloon-borne diode laser hygrometry a practical technique for more frequent use.


Sign in / Sign up

Export Citation Format

Share Document