Specifying The Optical System With An Optical Design Data Sheet

1980 ◽  
Author(s):  
P. R. Yoder ◽  
R. E. Casas
2012 ◽  
Vol 497 ◽  
pp. 304-310
Author(s):  
Song Chon Park ◽  
Toshiro K. Doi ◽  
Syuhei Kurokawa ◽  
Osamu Ohnishi

We composed optical system which is made of two optical lenses, beam expander, and Laser Diode(LD). When the light from the LD pointed to the remote moving object, we optically aligned to achieve full power performance in the given angle range. We also reviewed optical design data with Light Tools, and measured some factors including LD cell, surface roughness and refringence. The result shows that the laser point source optical system displayed good uniform power shape, and the LD used for this experiment to be guaranteed superior output power performance compared to conventional specifications.


Author(s):  
John W. Coleman

In the design engineering of high performance electromagnetic lenses, the direct conversion of electron optical design data into drawings for reliable hardware is oftentimes difficult, especially in terms of how to mount parts to each other, how to tolerance dimensions, and how to specify finishes. An answer to this is in the use of magnetostatic analytics, corresponding to boundary conditions for the optical design. With such models, the magnetostatic force on a test pole along the axis may be examined, and in this way one may obtain priority listings for holding dimensions, relieving stresses, etc..The development of magnetostatic models most easily proceeds from the derivation of scalar potentials of separate geometric elements. These potentials can then be conbined at will because of the superposition characteristic of conservative force fields.


2021 ◽  
Vol 2112 (1) ◽  
pp. 012007
Author(s):  
Chong Song ◽  
Yong Huang ◽  
Yangdong Yan ◽  
Dongsen Cui ◽  
Gang Wang ◽  
...  

Abstract An improved Offner imaging spectrometer was proposed based on the optical system characteristics of Offner imaging spectrometer, which can ensure perfect imaging quality in a wider annular region. The operating wavelength of the improved Offner imaging spectrometer ranges from 900nm to 1700nm, and the magnification is 1. Improved Offner imaging spectrometer can be obtained by changing the meniscus lens position and further optimizing the design. The results indicate that the improved Offner imaging spectrometer can effectively improve compactness and lightweight, and reduce the difficulty of optical adjustment, which is conducive to the stability of practical application.


2021 ◽  
Vol 2112 (1) ◽  
pp. 012021
Author(s):  
Chong Song ◽  
Lipeng Huo ◽  
Yong Huang ◽  
Yangdong Yan ◽  
Gang Wang ◽  
...  

Abstract Based on the optical system characteristics of coded aperture snapshot spectral imager (CASSI), an optimized optical system of shortwave infrared dual camera CASSI was designed based on improved Offner-Wynne imaging spectrometer. The operating wavelength of the optical system ranges from 900nm to 1700nm, and the focal length is 1200mm. It consists of two parts: the two dimensional imaging system and the multispectral CASSI imaging system. The key technical parameters of the two parts are the same and there is no visual axis difference. Therefore, the optimized optical system can effectively improve real-time performance, optical transmittance and compactness of the dual camera shortwave infrared CASSI, which is conducive to the application in optical measurement scenes in the shooting range.


2013 ◽  
Vol 33 (10) ◽  
pp. 1022002
Author(s):  
刘军 Liu Jun ◽  
刘伟奇 Liu Weiqi ◽  
康玉思 Kang Yusi ◽  
吕博 Lü Bo ◽  
冯睿 Feng Rui ◽  
...  

2013 ◽  
Vol 303-306 ◽  
pp. 335-338
Author(s):  
Nan Zhao ◽  
Zhi Yuan Sun

Interferometry is a very important method in high accuracy measurement for optical system. This article briefly introduced the conception of interferometry and took a product of 4D Technology as an example to carry on the measurement. A large-scale optic-electrical Theodolite in assemblage was measured, and its primary mirror was 400mm in diameter. With the analysis of the results, some micro adjustments of the mechanical structure proceed, and it made the system perform better. The final results of the whole system is 1.061λ in P-V value and 0.1136λ in RMS value (λ=632.8nm), this meets the demand of optical design and practical application. The result demonstrates that interferometry is a good way to be utilized and optimize in the procedure of assemble.


2014 ◽  
Vol 513-517 ◽  
pp. 796-799
Author(s):  
Jun Hai Jiang ◽  
Xiao Hui Yang

CAD is presented in optical design, the use of object-oriented methods, optical lens structure described. Using object-oriented techniques to describe the object lens, and with VC++ language features to build such systems, construct a data structure of the optical system components. This method has a simple structure, portability, reusability of characteristics.


Sign in / Sign up

Export Citation Format

Share Document