scholarly journals Individualized prediction of the sound pressure at the eardrum for an earpiece with integrated receivers and microphones

2019 ◽  
Vol 145 (2) ◽  
pp. 917-930 ◽  
Author(s):  
Steffen Vogl ◽  
Matthias Blau
1992 ◽  
Vol 1 (4) ◽  
pp. 52-55 ◽  
Author(s):  
Gail L. MacLean ◽  
Andrew Stuart ◽  
Robert Stenstrom

Differences in real ear sound pressure levels (SPLs) with three portable stereo system (PSS) earphones (supraaural [Sony Model MDR-44], semiaural [Sony Model MDR-A15L], and insert [Sony Model MDR-E225]) were investigated. Twelve adult men served as subjects. Frequency response, high frequency average (HFA) output, peak output, peak output frequency, and overall RMS output for each PSS earphone were obtained with a probe tube microphone system (Fonix 6500 Hearing Aid Test System). Results indicated a significant difference in mean RMS outputs with nonsignificant differences in mean HFA outputs, peak outputs, and peak output frequencies among PSS earphones. Differences in mean overall RMS outputs were attributed to differences in low-frequency effects that were observed among the frequency responses of the three PSS earphones. It is suggested that one cannot assume equivalent real ear SPLs, with equivalent inputs, among different styles of PSS earphones.


2020 ◽  
Vol 63 (4) ◽  
pp. 931-947
Author(s):  
Teresa L. D. Hardy ◽  
Carol A. Boliek ◽  
Daniel Aalto ◽  
Justin Lewicke ◽  
Kristopher Wells ◽  
...  

Purpose The purpose of this study was twofold: (a) to identify a set of communication-based predictors (including both acoustic and gestural variables) of masculinity–femininity ratings and (b) to explore differences in ratings between audio and audiovisual presentation modes for transgender and cisgender communicators. Method The voices and gestures of a group of cisgender men and women ( n = 10 of each) and transgender women ( n = 20) communicators were recorded while they recounted the story of a cartoon using acoustic and motion capture recording systems. A total of 17 acoustic and gestural variables were measured from these recordings. A group of observers ( n = 20) rated each communicator's masculinity–femininity based on 30- to 45-s samples of the cartoon description presented in three modes: audio, visual, and audio visual. Visual and audiovisual stimuli contained point light displays standardized for size. Ratings were made using a direct magnitude estimation scale without modulus. Communication-based predictors of masculinity–femininity ratings were identified using multiple regression, and analysis of variance was used to determine the effect of presentation mode on perceptual ratings. Results Fundamental frequency, average vowel formant, and sound pressure level were identified as significant predictors of masculinity–femininity ratings for these communicators. Communicators were rated significantly more feminine in the audio than the audiovisual mode and unreliably in the visual-only mode. Conclusions Both study purposes were met. Results support continued emphasis on fundamental frequency and vocal tract resonance in voice and communication modification training with transgender individuals and provide evidence for the potential benefit of modifying sound pressure level, especially when a masculine presentation is desired.


2020 ◽  
Vol 63 (6) ◽  
pp. 2016-2026
Author(s):  
Tamara R. Almeida ◽  
Clayton H. Rocha ◽  
Camila M. Rabelo ◽  
Raquel F. Gomes ◽  
Ivone F. Neves-Lobo ◽  
...  

Purpose The aims of this study were to characterize hearing symptoms, habits, and sound pressure levels (SPLs) of personal audio system (PAS) used by young adults; estimate the risk of developing hearing loss and assess whether instructions given to users led to behavioral changes; and propose recommendations for PAS users. Method A cross-sectional study was performed in 50 subjects with normal hearing. Procedures included questionnaire and measurement of PAS SPLs (real ear and manikin) through the users' own headphones and devices while they listened to four songs. After 1 year, 30 subjects answered questions about their usage habits. For the statistical analysis, one-way analysis of variance, Tukey's post hoc test, Lin and Spearman coefficients, the chi-square test, and logistic regression were used. Results Most subjects listened to music every day, usually in noisy environments. Sixty percent of the subjects reported hearing symptoms after using a PAS. Substantial variability in the equivalent music listening level (Leq) was noted ( M = 84.7 dBA; min = 65.1 dBA, max = 97.5 dBA). A significant difference was found only in the 4-kHz band when comparing the real-ear and manikin techniques. Based on the Leq, 38% of the individuals exceeded the maximum daily time allowance. Comparison of the subjects according to the maximum allowed daily exposure time revealed a higher number of hearing complaints from people with greater exposure. After 1 year, 43% of the subjects reduced their usage time, and 70% reduced the volume. A volume not exceeding 80% was recommended, and at this volume, the maximum usage time should be 160 min. Conclusions The habit of listening to music at high intensities on a daily basis seems to cause hearing symptoms, even in individuals with normal hearing. The real-ear and manikin techniques produced similar results. Providing instructions on this topic combined with measuring PAS SPLs may be an appropriate strategy for raising the awareness of people who are at risk. Supplemental Material https://doi.org/10.23641/asha.12431435


1963 ◽  
Vol 6 (4) ◽  
pp. 359-368 ◽  
Author(s):  
Charles I. Berlin

Hearing in mice has been difficult to measure behaviorally. With GSR as the basic tool, the sensitivity curve to pure tones in mice has been successfully outlined. The most sensitive frequency-intensity combination was 15 000 cps at 0-5 dB re: 0.0002 dyne/cm 2 , with responses noted from 1 000 to beyond 70 000 cps. Some problems of reliability of conditioning were encountered, as well as findings concerning the inverse relationship between the size of GSR to unattenuated tones and the sound pressure necessary to elicit conditioned responses at or near threshold. These data agree well with the sensitivity of single units of the eighth nerve of the mouse.


1986 ◽  
Vol 29 (3) ◽  
pp. 420-424 ◽  
Author(s):  
Michael Dorman ◽  
Ingrid Cedar ◽  
Maureen Hannley ◽  
Marjorie Leek ◽  
Julie Mapes Lindholm

Computer synthesized vowels of 50- and 300-ms duration were presented to normal-hearing listeners at a moderate and high sound pressure level (SPL). Presentation at the high SPL resulted in poor recognition accuracy for vowels of a duration (50 ms) shorter than the latency of the acoustic stapedial reflex. Presentation level had no effect on recognition accuracy for vowels of sufficient duration (300 ms) to elicit the reflex. The poor recognition accuracy for the brief, high intensity vowels was significantly improved when the reflex was preactivated. These results demonstrate the importance of the acoustic reflex in extending the dynamic range of the auditory system for speech recognition.


2020 ◽  
pp. 67-72
Author(s):  
A. V. Konkov ◽  
D. V. Golovin

The influence of environmental conditions on a sound pressure reproduced by the primary method in the measuring chambers of the Pistonphone in the frequency range from 1 mHz to 250 Hz is estimated. Numerical estimations of influence of environmental conditions on sound pressure in pistonphone measuring chambers are given and special requirements to system of maintenance of required external conditions are specified.


2018 ◽  
Vol 595 ◽  
pp. 245-252 ◽  
Author(s):  
SK Archer ◽  
WD Halliday ◽  
A Riera ◽  
X Mouy ◽  
MK Pine ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document