scholarly journals Inverse Dynamics Modeling of Paralympic Wheelchair Curling

2017 ◽  
Vol 33 (4) ◽  
pp. 294-299 ◽  
Author(s):  
Brock Laschowski ◽  
Naser Mehrabi ◽  
John McPhee

Paralympic wheelchair curling is an adapted version of Olympic curling played by individuals with spinal cord injuries, cerebral palsy, multiple sclerosis, and lower extremity amputations. To the best of the authors’ knowledge, there has been no experimental or computational research published regarding the biomechanics of wheelchair curling. Accordingly, the objective of the present research was to quantify the angular joint kinematics and dynamics of a Paralympic wheelchair curler throughout the delivery. The angular joint kinematics of the upper extremity were experimentally measured using an inertial measurement unit system; the translational kinematics of the curling stone were additionally evaluated with optical motion capture. The experimental kinematics were mathematically optimized to satisfy the kinematic constraints of a subject-specific multibody biomechanical model. The optimized kinematics were subsequently used to compute the resultant joint moments via inverse dynamics analysis. The main biomechanical demands throughout the delivery (ie, in terms of both kinematic and dynamic variables) were about the hip and shoulder joints, followed sequentially by the elbow and wrist. The implications of these findings are discussed in relation to wheelchair curling delivery technique, musculoskeletal modeling, and forward dynamic simulations.

2015 ◽  
Vol 138 (1) ◽  
Author(s):  
Joseph E. Barton ◽  
Anindo Roy ◽  
John D. Sorkin ◽  
Mark W. Rogers ◽  
Richard Macko

We developed a balance measurement tool (the balanced reach test (BRT)) to assess standing balance while reaching and pointing to a target moving in three-dimensional space according to a sum-of-sines function. We also developed a three-dimensional, 13-segment biomechanical model to analyze performance in this task. Using kinematic and ground reaction force (GRF) data from the BRT, we performed an inverse dynamics analysis to compute the forces and torques applied at each of the joints during the course of a 90 s test. We also performed spectral analyses of each joint's force activations. We found that the joints act in a different but highly coordinated manner to accomplish the tracking task—with individual joints responding congruently to different portions of the target disk's frequency spectrum. The test and the model also identified clear differences between a young healthy subject (YHS), an older high fall risk (HFR) subject before participating in a balance training intervention; and in the older subject's performance after training (which improved to the point that his performance approached that of the young subject). This is the first phase of an effort to model the balance control system with sufficient physiological detail and complexity to accurately simulate the multisegmental control of balance during functional reach across the spectra of aging, medical, and neurological conditions that affect performance. Such a model would provide insight into the function and interaction of the biomechanical and neurophysiological elements making up this system; and system adaptations to changes in these elements' performance and capabilities.


Author(s):  
Miguel Silva ◽  
Jorge Ambro´sio

The use of inverse dynamics methodologies for the evaluation of intersegmental reaction forces and the moments-of-force at the anatomical joints, in the framework of gait analysis, not only requires that appropriate biomechanical models are used but also that kinematic and kinetic data sets are available. This paper discusses the quality of the results of the inverse dynamics analysis with respect to the filtering procedures used and the kinematic consistency of the position, velocity and acceleration data. A three-dimensional whole body response biomechanical model based on a multibody formulation with natural coordinates is used. The model has 16 anatomical segments that are described using 33 rigid bodies in a total of 44 degrees-of-freedom. In biomechanical applications, one of the advantages of the current formulation is that the set of anatomical points used to reconstruct the spatial motion of the subject is also used to construct the set of natural coordinates that describe the biomechanical model itself. Based on the images collected by four synchronized video cameras, the three-dimensional trajectories of the anatomical points are reconstructed using standard photogrammetry techniques and Direct Linear Transformations. The trajectories obtained are then filtered in order to reduce the noise levels introduced during the reconstruction procedure using 2nd order Butterworth low-pass filters with properly chosen cut-off frequencies. The filtered data is used in the inverse dynamics analysis either directly or after being modified in order to ensure its consistency with the biomechanical model’s kinematic constraints. It is also shown that the use of velocities and accelerations consistent with the kinematic constraints or those obtained through the time derivatives of the spline interpolation curves of the reconstructed trajectories lead to similar results.


Author(s):  
Robbin Romijnders ◽  
Elke Warmerdam ◽  
Clint Hansen ◽  
Julius Welzel ◽  
Gerhard Schmidt ◽  
...  

Abstract Background Identification of individual gait events is essential for clinical gait analysis, because it can be used for diagnostic purposes or tracking disease progression in neurological diseases such as Parkinson’s disease. Previous research has shown that gait events can be detected from a shank-mounted inertial measurement unit (IMU), however detection performance was often evaluated only from straight-line walking. For use in daily life, the detection performance needs to be evaluated in curved walking and turning as well as in single-task and dual-task conditions. Methods Participants (older adults, people with Parkinson’s disease, or people who had suffered from a stroke) performed three different walking trials: (1) straight-line walking, (2) slalom walking, (3) Stroop-and-walk trial. An optical motion capture system was used a reference system. Markers were attached to the heel and toe regions of the shoe, and participants wore IMUs on the lateral sides of both shanks. The angular velocity of the shank IMUs was used to detect instances of initial foot contact (IC) and final foot contact (FC), which were compared to reference values obtained from the marker trajectories. Results The detection method showed high recall, precision and F1 scores in different populations for both initial contacts and final contacts during straight-line walking (IC: recall $$=$$ = 100%, precision $$=$$ = 100%, F1 score $$=$$ = 100%; FC: recall $$=$$ = 100%, precision $$=$$ = 100%, F1 score $$=$$ = 100%), slalom walking (IC: recall $$=$$ = 100%, precision $$\ge$$ ≥ 99%, F1 score $$=$$ = 100%; FC: recall $$=$$ = 100%, precision $$\ge$$ ≥ 99%, F1 score $$=$$ = 100%), and turning (IC: recall $$\ge$$ ≥ 85%, precision $$\ge$$ ≥ 95%, F1 score $$\ge$$ ≥ 91%; FC: recall $$\ge$$ ≥ 84%, precision $$\ge$$ ≥ 95%, F1 score $$\ge$$ ≥ 89%). Conclusions Shank-mounted IMUs can be used to detect gait events during straight-line walking, slalom walking and turning. However, more false events were observed during turning and more events were missed during turning. For use in daily life we recommend identifying turning before extracting temporal gait parameters from identified gait events.


1992 ◽  
Vol 278 ◽  
Author(s):  
Marc R. Nyden ◽  
James E. Brown ◽  
S. M. Lomakin

AbstractMolecular dynamic simulations were used to identify factors which promote char formation during the thermal degradation of polymers. Computer movies based on these simulations, indicate that cross-linked model polymers tend to undergo further cross-linking when burned, eventually forming a high molecular weight, thermally stable char. This prediction was confirmed by char yield measurements made on γ and e - irradiated polyethylene and chemically cross-linked poly(methyl methacrylate).


2014 ◽  
Vol 14 (06) ◽  
pp. 1440003
Author(s):  
KAP-SOO HAN ◽  
CHANG HO YU ◽  
MYOUNG-HWAN KO ◽  
TAE KYU KWON

The objective of the study was to investigate the effects of 3D stabilization exercises using a whole body tilt device on forces in the trunk, such as individual muscle forces and activation patterns, maximum muscle activities and spine loads. For this sake, a musculoskeletal (MS) model of the whole body was developed, and an inverse dynamics analysis was performed to predict the forces on the spine. An EMG measurement experiment was conducted to validate the muscle forces and activation patterns. The MS model was rotated and tilted in eight different directions: anterior (A), posterior (P), anterior right (AR), posterior right (PR), anterior left (AL), posterior left (PL), right (R) and left (L), replicating the directions of the 3D spine balance exercise device, as performed in the experiment. The anterior directions of the tilt primarily induced the activation of long and superficial back muscles and the posterior directions activated the front muscles. However, deep muscles, such as short muscles and multifidi, were activated in all directions of the tilt. The resultant joint forces in the right and left directions of the tilt were the least among the directions, but higher muscle activations and more diverse muscle recruitments than other positions were observed. Therefore, these directions of tilt may be suitable for the elderly and rehabilitation patients who require muscle strengthening with less spinal loads. In the present investigation, it was shown that 3D stabilization exercises could provide considerable muscle exercise effects with a minimum perturbation of structure. The results of this study can be used to provide safety guidelines for muscle exercises using this type of tilting device. Therefore, the proposed direction of tilt can be used to strengthen targeted muscles, depending on the patients' muscular condition.


2021 ◽  
Author(s):  
Christopher Bailey ◽  
Thomas Uchida ◽  
Julie Nantel ◽  
Ryan Graham

Motor variability in gait is frequently linked to fall risk, yet field-based biomechanical joint evaluations are scarce. We evaluated the validity and sensitivity of an inertial measurement unit (IMU)-driven biomechanical model of joint angle variability for gait. Fourteen healthy young adults completed seven-minute trials of treadmill gait at several speeds and arm swing amplitudes. Joint kinematics were estimated by IMU- and optoelectronic-based models using OpenSim. We calculated range of motion (ROM), magnitude of variability (meanSD), local dynamic stability (λmax), persistence of ROM fluctuations (DFAα), and regularity (SaEn) of each angle over 200 continuous strides, and evaluated model accuracy (e.g., RMSD: root mean square difference), consistency (ICC2,1: intraclass correlation), biases, limits of agreement, and sensitivity to within-participant gait responses (effects of Speed and Swing). RMSDs of joint angles were 1.7–7.5° (pooled mean of 4.8°), excluding ankle inversion. ICCs were mostly good–excellent in the primary plane of motion for ROM and in all planes for meanSD and λmax, but were poor–moderate for DFAα and SaEn. Modeled Speed and Swing responses for ROM, meanSD, and λmax were similar. Results suggest that the IMU-driven model is valid and sensitive for field-based assessments of joint angles and several motor variability features.


2018 ◽  
Vol 141 (3) ◽  
Author(s):  
Francesco Paparella ◽  
Satja Sivcev ◽  
Daniel Toal ◽  
John V. Ringwood

The measurement of the motion of a small-scale wave energy device during wave tank tests is important for the evaluation of its response to waves and the assessment of power production. Usually, the motion of a small-scale wave energy converter (WEC) is measured using an optical motion tracking system with high precision and sampling rate. However, the cost for an optical motion tracking system can be considerably high and, therefore, the overall cost for tank testing is increased. This paper proposes a low-cost capture system composed of an inertial measurement unit and ultrasound sensors. The measurements from the ultrasound sensors are combined optimally with the measurements from the inertial measurement unit through an extended Kalman filter (EKF) in order to obtain an accurate estimation of the motion of a WEC.


Author(s):  
Enguo Cao ◽  
MengYi Ren ◽  
YuTian Cui ◽  
Kun Wang ◽  
Bin Yang

Background In recent years, as the large own weight of active exoskeleton brings some difficulty to energy-sustainable, studies have shown that passive lower extremity exoskeletons can also reduce the energy consumption of human locomotion, but the energy saving is still relatively small compared with the total consumption. Methods A passive lower limb exoskeleton named Multi-Resiliency was described, and design parameters were estimated based on inverse dynamics. Furthermore, a series of experiments was designed for assessing the assisting effect of the exoskeleton in uphill walking and upstairs activities. Results In the inverse dynamics analysis, the spring release angle θmax was confirmed to be 45° for increasing assist performance of the exoskeleton. In the exoskeleton wearing experiments, the energy expenditure of subjects were decreased by 14.3% in uphill walking test and 16.0% in stair climbing test respectively. Conclusion The results show that the design of Multi-Resiliency exoskeleton is reasonable and it may effectively improve walking efficiency during uphill walking and stair climbing activities.


Sign in / Sign up

Export Citation Format

Share Document