Utility of Computer-Assisted Approaches for Population Surveillance of Physical Activity

2014 ◽  
Vol 11 (6) ◽  
pp. 1111-1119 ◽  
Author(s):  
MeLisa Creamer ◽  
Heather R. Bowles ◽  
Belinda von Hofe ◽  
Kelley Pettee Gabriel ◽  
Harold W. Kohl ◽  
...  

Background:Computer-assisted techniques may be a useful way to enhance physical activity surveillance and increase accuracy of reported behaviors.Purpose:Evaluate the reliability and validity of a physical activity (PA) self-report instrument administered by telephone and internet.Methods:The telephone-administered Active Australia Survey was adapted into 2 forms for internet self-administration: survey questions only (internet-text) and with videos demonstrating intensity (internet-video). Data were collected from 158 adults (20–69 years, 61% female) assigned to telephone (telephone-interview) (n = 56), internet-text (n = 51), or internet-video (n = 51). Participants wore an accelerometer and completed a logbook for 7 days. Test-retest reliability was assessed using intraclass correlation coefficients (ICC). Convergent validity was assessed using Spearman correlations.Results:Strong test-retest reliability was observed for PA variables in the internet-text (ICC = 0.69 to 0.88), internet-video (ICC = 0.66 to 0.79), and telephone-interview (ICC = 0.69 to 0.92) groups (P-values < 0.001). For total PA, correlations (ρ) between the survey and Actigraph+logbook were ρ = 0.47 for the internet-text group, ρ = 0.57 for the internet-video group, and ρ = 0.65 for the telephone-interview group. For vigorous-intensity activity, the correlations between the survey and Actigraph+logbook were 0.52 for internet-text, 0.57 for internet-video, and 0.65 for telephone-interview (P < .05).Conclusions:Internet-video of the survey had similar test-retest reliability and convergent validity when compared with the telephone-interview, and should continue to be developed.

2008 ◽  
Vol 25 (1) ◽  
pp. 23-34 ◽  
Author(s):  
David R. Lubans ◽  
Kathy Sylva ◽  
Zane Osborn

AbstractThe purpose of this study was to examine the convergent validity and test–retest reliability of the Oxford Physical Activity Questionnaire (OPAQ), a self-administered questionnaire designed to assess the activity patterns of adolescents. The test–retest reliability of the OPAQ was assessed by administering the questionnaire on two occasions separated by 1 week (N = 87, mean age = 13.1 ± .9). Intraclass correlation (ICC) was used to examine the test–retest reliability of the OPAQ. The convergent validity of the OPAQ was evaluated using Caltrac accelerometers worn consecutively for 4 days (N = 51, mean age = 12.6 ± .5). Spearman's rank-order correlation was used to examine the convergent validity of the questionnaire. ICCs ranged from .76 to .91 and reliability was higher for males (r = .89) than females (r = .78). Correlations between self-reported physical activity and Caltrac accelerometer counts were related to vigorous physical activity (r = .33, p = .01) and moderate to vigorous activity (r = .32, p = .02). The OPAQ has excellent test–retest reliability and acceptable validity in comparison to other measures of youth physical activity.


2014 ◽  
Vol 22 (2) ◽  
pp. 245-254 ◽  
Author(s):  
Casey Jordan Mace ◽  
Ralph Maddison ◽  
Timothy Olds ◽  
Ngaire Kerse

Background:The Multimedia Activity Recall for Children and Adults (MARCA) is a computerized recall instrument that records use of time during 24 hr the previous day and has been developed to address limitations of current self-report physical activity measures for those in advanced age.Methods:Test–retest reliability and convergent validity of the adult MARCA were assessed in a sample of 45 advanced-age adults (age 84.9SD ±1.62 yr) as a subsample of the Life and Living in Advanced-Age Cohort Study New Zealand (LiLACS NZ). Test–retest methods required participants to recall the previous day’s activity using the MARCA twice within the same day. Convergent validity was assessed against accelerometry.Results:Test–retest reliability was high, with ICCs greater than .99 for moderate to vigorous physical activity (MVPA) and physical activity level (PAL). Compared with accelerometry, the MARCA demonstrated validity comparable to other self-report instruments with Spearman’s coefficients of .34 and .59 for time spent in nonsedentary physical activity and PAL.Conclusion:The MARCA is a valid and reliable self-report tool for physical activity behaviors in advanced-age adults.


BMC Neurology ◽  
2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Mohammad-Reza Fattahi ◽  
Pardis Noormohammadpour ◽  
Meysam Ramezani ◽  
Mohammad Ali Sahraian ◽  
Mohammad Ali Mansournia ◽  
...  

Abstract Study Design Psychometric study. Objective The purpose of this study is to translate, culturally adapt and evaluate the validity and reliability of the Persian (Farsi) version of GLTEQ in patients with multiple sclerosis. Methods This study had three phases, including translation of the questionnaire into Persian and making cultural adaptation, evaluation of pre-final version of questionnaire’s comprehensibility in a pilot study, and investigation of reliability and validity of the final version of the translated questionnaire. Content validity, and convergent validity (correlations among the Persian version of GLTEQ and Global physical activity questionnaire (GPAQ), and international physical activity questionnaire (IPAQ)) and after all test-retest reliability were studied. Results The subjects were 87 MS patients. The Persian version demonstrated moderate to good convergent validity; the correlation coefficient between the Persian version and GPAQ was r=0.64 (p<0.001), and between the Persian version and IPAQ was r=0.59 (p<0.001). The test-retest reliability was strong (Intra-class Correlation (ICC) value ranged between 0.908 and 0.992). Besides, its face validity and content validity were acceptable. Conclusions The Persian version of GLTEQ is a valid and reliable instrument to assess physical activity in patients with MS. This questionnaire can be a step toward standardization of physical activity measurement in patients with MS. Also, in research, it provides the possibilities to carry on a comparative study across cultures using the same outcome measure.


Rheumatology ◽  
2021 ◽  
Author(s):  
Bonny Rockette-Wagner ◽  
Didem Saygin ◽  
Siamak Moghadam-Kia ◽  
Chester Oddis ◽  
Océane Landon-Cardinal ◽  
...  

Abstract Objective Idiopathic inflammatory myopathies (IIM) cause proximal muscle weakness, which affect activities of daily living. Wearable physical activity monitors (PAMs) objectively assess continuous activity with potential clinical usefulness in IIM assessment. We examined the psychometric characteristics for PAM outcomes in IIM. Methods Adult IIM patients were prospectively evaluated (baseline, 3 and 6-months) in an observational study. A waist-worn PAM (ActiGraph GT3X-BT) assessed average step counts/min, peak 1-min cadence, and vector magnitude/min. Validated myositis core set measures (CSM) including manual muscle testing (MMT), physician global disease activity (MD global), patient global disease activity (Pt global), extra-muscular disease activity (Ex-muscular global), HAQ-DI, muscle enzymes, and patient-reported physical function were evaluated. Test-retest reliability, construct validity, and responsiveness were determined for PAM measures and CSM using Pearson correlations and other appropriate analyses. Results 50 adult IIM patients enrolled [mean (SD) age, 53.6 (±14.6); 60% female, 94% Caucasian]. PAM measures showed strong test-retest reliability, moderate-to-strong correlations at baseline with MD global (r=-0.37- -0.48), Pt-global (r=-0.43- -0.61), HAQ-DI (r=-0.47- -0.59) and MMT (r = 0.37–0.52), and strong discriminant validity for categorical MMT and HAQ-DI. Longitudinal association with MD global (r=-0.38- -0.44), MMT (r = 0.50–0.57), HAQ-DI (r=-0.45- -0.55), and functional tests (r = 0.30–0.65) were moderate-to-strong. PAM measures were responsive to MMT improvement (≥10%) and moderate-to-major improvement on ACR/EULAR myositis response criteria. Peak 1-min cadence had the largest effect size and Standardized Response Means (SRMs). Conclusion PAM measures showed promising construct validity, reliability, and longitudinal responsiveness; especially peak 1-min cadence. PAMs provide valid outcome measures for future use in IIM clinical trials.


2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Taweewat Wiangkham ◽  
Nattawan Phungwattanakul ◽  
Patcharin Tedsombun ◽  
Isara Kongmee ◽  
Wanisara Suwanmongkhon ◽  
...  

AbstractObjectivesFear-avoidance beliefs questionnaire (FABQ) is a self-report, valid and reliable questionnaire to quantify fear and avoidance beliefs related to physical activity and work. Furthermore, it can be used to predict prolong disability in patients with non-specific neck pain. Although it was originally developed to manage patients with low back pain, it has also been studied in individuals with neck pain. This questionnaire was translated into several languages following reports of potential benefits in patients with neck pain. Recently, Thai neck clinical trials, international multi-centre trials and data sharing are growing throughout the world but no validated Thai version of the FABQ is available for clinical and research uses. Our objectives were to translate and cross-culturally adapt the FABQ into Thai version and evaluate its psychometric properties in Thai patients with non-specific neck pain.MethodsCross-cultural translation and adaptation of the FABQ were conducted according to standard guidelines. A total of 129 participants with non-specific neck pain were invited to complete the Thai versions of the FABQ (FABQ-TH), neck disability index and visual analogue scale for pain intensity. Psychometric evaluation included exploratory factor analysis, internal consistency, test-retest reliability, agreement, and convergent validity. Thirty participants completed the FABQ-TH twice with a 48-h interval between tests to assess the test-retest reliability.ResultsFactor analysis identified four components for the FABQ-TH (66.69% of the total variance). The intraclass correlation coefficient of test-retest reliability was excellent for the total score (0.986), work attitudes (0.995), physical activity attitudes (0.958), physical activity experiences (0.927), and expected recovery (0.984). Cronbach’s alpha for internal consistency was excellent (range 0.87–0.88) for all items. The minimal detectable change of the FABQ-TH was 5.85. The FABQ-TH correlated to its subscales (range 0.470–0.936), indicating the strongest association with work attitude. The weakest correlation was observed between the FABQ-TH and disability (rs=0.206, p=0.01). Missing data and significant floor or ceiling effects were not found.ConclusionsThe Thai version of the FABQ for non-specific neck pain was successfully adapted. It is a valid and reliable instrument to quantify fear and avoidance beliefs among patients with non-specific neck pain who speak and read Thai.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Kuan-Wei Chen ◽  
Ya-Chen Lee ◽  
Tzu-Ying Yu ◽  
Li-Jung Cheng ◽  
Chien-Yu Chao ◽  
...  

Abstract Background Fluid intelligence deficits affect executive functioning and social behaviors in patients with schizophrenia. To help clinicians manage fluid intelligence deficits, a psychometrically sound measure is needed. The purposes of this study were to examine the test–retest reliability and convergent validity of the Test of Nonverbal Intelligence-Fourth Edition (TONI-4) assessing fluid intelligence in patients with schizophrenia. Methods A total of 103 patients with stable condition were assessed with the TONI-4 twice with a 4-week interval to examine the test–retest reliability. We further used the Montreal Cognitive Assessment (MoCA) and the Tablet-Based Symbol Digit Modalities Test (T-SDMT) to examine the convergent validity of the TONI-4. Results The intra-class correlation coefficient was 0.73 for the TONI-4. The percentages of standard error of measurement and minimal detectable change for the TONI-4 were 5.1 and 14.2%, respectively. The practice effect of the TONI-4 was small (Cohen’s d = − 0.03). Convergent validity showed small to moderate significant correlations between the TONI-4 and the MoCA as well as the T-SDMT (r = 0.35, p = .011 with the T-SDMT and r = 0.61, p < .001 with the MoCA). The results demonstrated that the TONI-4 had good test–retest reliability, limited random measurement error, and a trivial practice effect. The convergent validity of the TONI-4 was good. Conclusions These findings indicate that the TONI-4 has potential to be a reliable and valid assessment of fluid intelligence in patients with schizophrenia.


2021 ◽  
Author(s):  
Qi Zhang ◽  
Ke Zhang ◽  
Miao Li ◽  
Jiaxin Gu ◽  
Xintong Li ◽  
...  

Abstract Objectives To examine the validity and reliability of the Mandarin version of the Treatment Burden Questionnaire (TBQ) among stroke patients. Background Stroke patients need long-term management of symptoms and life situation, and treatment burden has recently emerged as a new concept that can influence the health outcomes during the rehabilitation process. Methods The convenience sampling method was used to recruit 187 cases of stroke patients in a tertiary grade hospital in Tianjin for a formal investigation. Item analysis, reliability and validity tests were carried out. The reliability test included internal consistency and test–retest reliability. And as well as content, structure and convergent validity were performed for the validity test. Results Of the 187 completed questionnaires, only 180 (96.3%) were suitable for analysis. According to the experts’ evaluation, the I-CVI of each item was from 0.833 to 1.000, and the S-CVI was 0.967. The exploratory factor analysis yielded three-factor components with a cumulative variation of 53.054%. Convergent validity was demonstrated using measures of Morisky’s Medication Adherence Scale 8 (r = –0.450, P &lt; 0.01). All correlations between items and global scores ranged from 0.403 to 0.638. Internal consistency reliability and test–retest reliability were found to be acceptable, as indicated by a Cronbach’s α of 0.824 and an intraclass correlation coefficient of 0.846, respectively. Conclusions The Mandarin TBQ had acceptable validity and reliability. The use of TBQ in the assessment of treatment burden of stroke survivor may benefit health resources allocation and provide tailor therapeutic interventions to construct minimally disruptive care.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Widjane Sheila Ferreira Goncalves ◽  
Rebecca Byrne ◽  
Pedro Israel Cabral de Lira ◽  
Marcelo Tavares Viana ◽  
Stewart G. Trost

Abstract Background Childhood obesity has increased remarkably in low and middle-income (LMIC) countries. Movement behaviors (physical activity, screen time, and sleep) are crucial in the development of overweight and obesity in young children. Yet, few studies have investigated the relationship between children’s movement behaviors and parenting practices because validated measures for use among families from LMIC are lacking. This study evaluated the psychometric properties of previously validated measures of young children’s physical activity, screen time, and sleep and parenting practices, translated and culturally adapted to Brazilian families. Methods A total of 78 parent-child dyads completed an interviewer-administered survey twice within 7 days. Child physical activity, sedentary time and sleep were concurrently measured using a wrist-worn accelerometer. Internal consistency and test-retest reliability was assessed using McDonald’s Omega and Intraclass Correlation Coefficients (ICC’s). Concurrent validity was evaluated by calculating Spearman correlations between parent reported child behaviors and accelerometer measured behaviors. Results Seventeen of the 19 parenting practices scales exhibited acceptable internal consistency reliability (Ω ≥ 0.70). Test-retest reliability ICC’s were acceptable and ranged from 0.82 - 0.99. Parent reported child physical activity was positively correlated with objectively measured total movement (rho= 0.29 - 0.46, p < .05) and energetic play (rho= 0.29 – 0.40, p < .05). Parent reported child screen time was positively correlated with objectively measured sedentary time; (rho = 0.26, p < .05), and inversely correlated with total movement (rho = - 0.39 – - 0.41, p < .05) and energetic play (rho = - 0.37 – - 0.41, p < .05). Parent reported night-time sleep duration was significantly correlated with accelerometer measured sleep duration on weekdays (rho = 0.29, p < .05), but not weekends. Conclusions Measurement tools to assess children’s movement behaviors and parenting practices, translated and culturally adapted for use in Brazilian families, exhibited acceptable evidence of concurrent validity, internal consistency, and test-retest reliability.


Author(s):  
Helmut Schröder ◽  
Isaac Subirana ◽  
Julia Wärnberg ◽  
María Medrano ◽  
Marcela González-Gross ◽  
...  

Abstract Background Validation of self-reported tools, such as physical activity (PA) questionnaires, is crucial. The aim of this study was to determine test-retest reliability, internal consistency, and the concurrent, construct, and predictive validity of the short semi-quantitative Physical Activity Unit 7 item Screener (PAU-7S), using accelerometry as the reference measurement. The effect of linear calibration on PAU-7S validity was tested. Methods A randomized sample of 321 healthy children aged 8–16 years (149 boys, 172 girls) from the nationwide representative PASOS study completed the PAU-7S before and after wearing an accelerometer for at least 7 consecutive days. Weight, height, and waist circumference were measured. Cronbach alpha was calculated for internal consistency. Test-retest reliability was determined by intra-class correlation (ICC). Concurrent validity was assessed by ICC and Spearman correlation coefficient between moderate to vigorous PA (MVPA) derived by the PAU-7S and by accelerometer. Concordance between both methods was analyzed by absolute agreement, weighted kappa, and Bland-Altman statistics. Multiple linear regression models were fitted for construct validity and predictive validity was determined by leave-one-out cross-validation. Results The PAU-7S overestimated MVPA by 18%, compared to accelerometers (106.5 ± 77.0 vs 95.2 ± 33.2 min/day, respectively). A Cronbach alpha of 0.76 showed an acceptable internal consistency of the PAU-7S. Test-retest reliability was good (ICC 0.71 p < 0.001). Spearman correlation and ICC coefficients of MVPA derived by the PAU-7S and accelerometers increased from 0.31 to 0.62 and 0.20 to 0.62, respectively, after calibration of the PAU-7S. Between-methods concordance improved from a weighted kappa of 0.24 to 0.50 after calibration. A slight reduction in ICC, from 0.62 to 0.60, yielded good predictive validity. Multiple linear regression models showed an inverse association of MVPA with standardized body mass index (β − 0.162; p < 0.077) and waist to height ratio (β − 0.010; p < 0.014). All validity dimensions were somewhat stronger in boys compared to girls. Conclusion The PAU-7S shows a good test-retest reliability and acceptable internal consistency. All dimensions of validity increased from poor/fair to moderate/good after calibration. The PAU-7S is a valid instrument for measuring MVPA in children and adolescents. Trial registration Trial registration numberISRCTN34251612.


Sign in / Sign up

Export Citation Format

Share Document