Oligo-heterotrophic activity of Marinobacter subterrani creates an indirect Fe(II)-oxidation phenotype in gradient tubes

Author(s):  
Abhiney Jain ◽  
Benjamin M. Bonis ◽  
Jeffrey A. Gralnick

Autotrophic bacteria utilizing Fe(II) as their energy and electron sources for growth affect multiple biogeochemical cycles. Some chemoheterotrophic bacteria have also been considered to exhibit an Fe(II) oxidation phenotype. For example, several Marinobacter strains have been reported to oxidize Fe(II) based on formation of oxidized iron bands in semi-solid gradient tubes that produce opposing concentration gradients of Fe(II) and oxygen. While gradient tubes are a simple and visually compelling method to test for Fe(II) oxidation, this method alone cannot confirm if, and to what extent, Fe(II) oxidation is linked to metabolism in chemoheterotrophic bacteria. Here we probe the possibility of protein-mediated and metabolic byproduct-mediated Fe(II) oxidation in Marinobacter subterrani JG233, a chemoheterotroph previously proposed to oxidize Fe(II). Results from conditional and mutant studies, along with measurements of Fe(II) oxidation rates suggest M. subterrani is unlikely to facilitate Fe(II) oxidation under microaerobic conditions. We conclude that the Fe(II) oxidation phenotype observed in gradient tubes inoculated with M. subterrani JG233 is a result of oligo-heterotrophic activity, shifting the location where oxygen dependent chemical Fe(II) oxidation occurs, rather than a biologically-mediated process. Importance Gradient tubes are the most commonly used method to isolate and identify neutrophilic Fe(II)-oxidizing bacteria. The formation of oxidized iron bands in gradient tubes provides a compelling assay to ascribe the ability to oxidize Fe(II) to autotrophic bacteria whose growth is dependent on Fe(II) oxidation. However, the physiological significance of Fe(II) oxidation in chemoheterotrophic bacteria is less well understood. Our work suggests that oligo-heterotrophic activity of certain bacteria may create a false-positive phenotype in gradient tubes by altering the location of the abiotic, oxygen-mediated oxidized iron band. Based on the results and analysis presented here, we caution against utilizing gradient tubes as the sole evidence for the capability of a strain to oxidize Fe(II) and that additional experiments are necessary to ascribe this phenotype to new isolates.

Author(s):  
W.R. Bottoms ◽  
G.B. Haydon

There is great interest in improving the brightness of electron sources and therefore the ability of electron optical instrumentation to probe the properties of materials. Extensive work by Dr. Crew and others has provided extremely high brightness sources for certain kinds of analytical problems but which pose serious difficulties in other problems. These sources cannot survive in conventional system vacuums. If one wishes to gather information from the other signal channels activated by electron beam bombardment it is necessary to provide sufficient current to allow an acceptable signal-to-noise ratio. It is possible through careful design to provide a high brightness field emission source which has the capability of providing high currents as well as high current densities to a specimen. In this paper we describe an electrode to provide long-lived stable current in field emission sources.The source geometry was based upon the results of extensive computer modeling. The design attempted to maximize the total current available at a specimen.


Author(s):  
G. Zampighi ◽  
M. Kreman

The plasma membranes of most animal cells contain transport proteins which function to provide passageways for the transported species across essentially impermeable lipid bilayers. The channel is a passive transport system which allows the movement of ions and low molecular weight molecules along their concentration gradients. The pump is an active transport system and can translocate cations against their natural concentration gradients. The actions and interplay of these two kinds of transport proteins control crucial cell functions such as active transport, excitability and cell communication. In this paper, we will describe and compare several features of the molecular organization of pumps and channels. As an example of an active transport system, we will discuss the structure of the sodium and potassium ion-activated triphosphatase [(Na+ +K+)-ATPase] and as an example of a passive transport system, the communicating channel of gap junctions and lens junctions.


Author(s):  
P. E. Batson

In recent years,instrumentation for electron energy loss spectroscopy (EELS) has been steadily improved to increase energy resolution and collection efficiency. At present 0.40eV at 10mR collection half angle is available with commercial magnetic sectors (e.g. Gatan, Inc. and VG Microscopes, Ltd.), and 70meV at 10mR has been demonstrated by use of a Wien filter within a large deceleration field. When these high resolution spectrometers are coupled to the modern small electron probe instrument, we obtain a tool which promises to reveal local changes in bandstructure and bonding near defects and interfaces in heterogeneous materials.Unfortunately, typical electron sources have intrinsic energy widths which limit attainable spectroscopic resolution in the absence of some monochromation system. For instance, the W thermal emitter has a half width of about 1eV.


Author(s):  
Vinayak P. Dravid ◽  
V. Ravikumar ◽  
Richard Plass

With the advent of coherent electron sources with cold field emission guns (cFEGs), it has become possible to utilize the coherent interference phenomenon and perform “practical” electron holography. Historically, holography was envisioned to extent the resolution limit by compensating coherent aberrations. Indeed such work has been done with reasonable success in a few laboratories around the world. However, it is the ability of electron holography to map electrical and magnetic fields which has caught considerable attention of materials science community.There has been considerable theoretical work on formation of space charge on surfaces and internal interfaces. In particular, formation and nature of space charge have important implications for the performance of numerous electroceramics which derive their useful properties from electrically active grain boundaries. Bonnell and coworkers, in their elegant STM experiments provided the direct evidence for GB space charge and its sign, while Chiang et al. used the indirect but powerful technique of x-ray microchemical profiling across GBs to infer the nature of space charge.


Author(s):  
W. Coene ◽  
A. Thust ◽  
M. Op de Beeck ◽  
D. Van Dyck

Compared to conventional electron sources, the use of a highly coherent field-emission gun (FEG) in TEM improves the information resolution considerably. A direct interpretation of this extra information, however, is hampered since amplitude and phase of the electron wave are scrambled in a complicated way upon transfer from the specimen exit plane through the objective lens towards the image plane. In order to make the additional high-resolution information interpretable, a phase retrieval procedure is applied, which yields the aberration-corrected electron wave from a focal series of HRTEM images (Coene et al, 1992).Kirkland (1984) tackled non-linear image reconstruction using a recursive least-squares formalism in which the electron wave is modified stepwise towards the solution which optimally matches the contrast features in the experimental through-focus series. The original algorithm suffers from two major drawbacks : first, the result depends strongly on the quality of the initial guess of the first step, second, the processing time is impractically high.


Author(s):  
David C Joy

The electron source is the most important component of the Scanning electron microscope (SEM) since it is this which will determine the overall performance of the machine. The gun performance can be described in terms of quantities such as its brightness, its source size, its energy spread, and its stability and, depending on the chosen application, any of these factors may be the most significant one. The task of the electron gun in an SEM is, in fact, particularly difficult because of the very wide range of operational parameters that may be required e.g a variation in probe size of from a few angstroms to a few microns, and a probe current which may go from less than a pico-amp to more than a microamp. This wide range of operating parameters makes the choice of the optimum source for scanning microscopy a difficult decision.Historically, the first step up from the sealed glass tube ‘cathode ray generator’ was the simple, diode, tungsten thermionic emitter.


Sign in / Sign up

Export Citation Format

Share Document