scholarly journals Absolute CD4 Counts Obtained by a Three-Color Flow-Cytometric Method without the Use of a Hematology Analyzer

1998 ◽  
Vol 5 (2) ◽  
pp. 266-269 ◽  
Author(s):  
Thomas S. Alexander

ABSTRACT We evaluated the Ortho TRIO-Cytoronabsolute system for determining absolute CD4 counts. The CD4 counts in our blood specimens from 100 individuals ranged from 3 to 1,962; the percent CD4 ranged from 1.3 to 62.2, respectively. The TRIO system was biased toward lower absolute counts than a combination of flow cytometry and hematology but showed no bias in percent CD4 calculations.

2008 ◽  
Vol 132 (5) ◽  
pp. 813-819
Author(s):  
Xiaohong Han ◽  
Jeffrey L. Jorgensen ◽  
Archana Brahmandam ◽  
Ellen Schlette ◽  
Yang O. Huh ◽  
...  

Abstract Context.—The immunophenotypic profile of basophils is not yet fully established, and the immunophenotypic changes in chronic myelogenous leukemia are not fully characterized. Objective.—To establish a comprehensive immunophenotypic spectrum of normal basophils and to assess the range of immunophenotypic aberrations of basophils in chronic myelogenous leukemia. Design.—Using 4-color flow cytometry, we compared the immunophenotypic profile of basophils in peripheral blood or bone marrow samples from 20 patients with no evidence of neoplasia to basophils from 15 patients with chronic myelogenous leukemia. Results.—Basophils in control cases were all positive for CD9, CD13, CD22, CD25 (dim), CD33, CD36, CD38 (bright), CD45 (dimmer than lymphocytes and brighter than myeloblasts), and CD123 (bright), and were negative for CD19, CD34, CD64, CD117, and HLA-DR. Basophils in all chronic myelogenous leukemia patients possessed 1 to 5 immunophenotypic aberrancies. The most common aberrancies were underexpression of CD38, followed by aberrant expression of CD64 and underexpression of CD123. CD34 and CD117 were present in cases with basophilic precursors. Myeloblasts showed a distinct immunophenotypic profile, as they typically expressed CD34 and CD117, showed dimmer expression (compared with basophils) of CD38, CD45, and CD123, and lacked expression of CD22. Conclusions.—Flow cytometric immunophenotyping can identify immunophenotypic aberrations of basophils in chronic myelogenous leukemia, and discriminate basophils from myeloblasts.


2017 ◽  
Vol 92 (6) ◽  
pp. 498-507 ◽  
Author(s):  
Julien Guy ◽  
Orianne Wagner-Ballon ◽  
Olivier Pages ◽  
François Bailly ◽  
Jessica Borgeot ◽  
...  

Blood ◽  
2012 ◽  
Vol 120 (21) ◽  
pp. 4799-4799
Author(s):  
Bettina Keller ◽  
Markus P Radsak ◽  
Joerg Faber ◽  
Alexandra Russo

Abstract Abstract 4799 Background: Rapid identification and quantification of abnormal cell populations in minimal specimen are crucial for diagnosis and longitudinal minimal residual disease (MRD) testing of childhood leukemia. So far, most standard immunophenotypic analyses are performed using antibody panels with up to five-colors and require high cell numbers. For infant and pediatric specimen, high-level multicolor analyses is highly desirable to gather sufficient data for initial diagnostic and follow up monitoring of pathologic populations. Objective: In this study, we aimed to establish a newly defined pediatric multicolor flow cytometric panel algorithm with high reliability yet minimal specimen requirement. Results: We defined a 10-color flow cytometric panel using the new violet laser dye “KromeOrange (KO)”. Applying CD45-KO/Side Scatter gating, combined with 2 additional backbone markers the panel is designed in two consecutive steps. In the first step, a single standardized 10-color-“screening tube” (FITC-HLA-DR, PE-CD15/CD56, ECD-CD5, PC5.5-CD33, PC7-CD13, APC-CD117, APC A700-CD34, APC A750-CD19, PB-CD3, KrO-CD45) is applied for initial orientation of specific lineage assignment. Based on results obtained with the screening tube, a specific multi-tube “classification panel” is used to complete detailed characterization of lineage specific malignancy and maturation stage. Suitable specimens include fresh blood, bone marrow and all body fluids. All samples are stained directly with monoclonal antibodies, followed by the lyses of erythrocytes and a short wash. Compared to standard five color panel previously used the application of greater numbers of informative antibodies in the screening tube and in the 2ndstep muti-tube classification panel is cost and time efficient and results in a more precise characterization of any single event. Conclusion: Our panel construction and algorithm definition for infant and pediatric leukemia immunophenotyping is one of the first 10-color flow cytometry panels described for this application. Advantages are the possibility to obtain highly specific information from minimal specimens with significantly improved laboratory efficiency. The overall performance is currently tested in a routine clinical setting. Disclosures: No relevant conflicts of interest to declare.


Blood ◽  
2015 ◽  
Vol 126 (23) ◽  
pp. 3099-3099 ◽  
Author(s):  
Thomas Porturas ◽  
Mary Sell ◽  
Leah Irwin ◽  
Una O'Doherty ◽  
Carlos Hipolito Villa

Abstract Background: Although peripheral blood CD34+ stem cell counts by flow cytometry correlate well with yields, the time, complexity, and cost associated with flow cytometry limits its utility. Rapid, cost-effective, surrogate predictors (with <1hr turnaround) would allow for same-visit analyses and alteration of collection and mobilization strategies, particularly for the optimal use of time-sensitive and costly agents such as plerixafor. We previously demonstrated that morphologic parameters of neutrophil-like cells measured by hematology analyzers correlated with CD34 counts. We aimed to improve these models by using multiple regression analyses on data from a common hematology analyzer. Methods: Patients undergoing stem cell apheresis were evaluated over a 6 month period. The day prior to initiation of apheresis, and on the morning of initial collection, peripheral blood samples were drawn into EDTA collection tubes and flow cytometric CD34 measurement and/or CBCs were performed on the Beckman Coulter DxH 800 hematology analyzer per standard protocol. CD34 cells were counted by flow cytometric ISHAGE protocols. Data from the DxH (48 variables per specimen) were exported into a data matrix with the corresponding flow cytometric data. Multiple regression analysis was performed using a step-wise method with log(peripheral CD34) as the dependent variable (SPSS, IBM). Data were randomly selected into a training-set of 70% of cases and a test-set of 30% of cases for validation. The derived model was further tested against peripheral blood data from the morning of collection to predict harvest yields. Further analyses were performed using Prism (GraphPad). Results: Tandem peripheral blood CD34 counts and CBC cell-population data were obtained from 69 blood samples in 64 patients. The population included patients with multiple myeloma (45), non-Hodgkin lymphoma (12), Hodgkin lymphoma (5), and amyloidosis (2). 41% of patients were female. In the test data set examining collection yields, 37 patients were mobilized with GCSF (+/- chemotherapy) alone, while 17 had plerixafor added to the regimen. 33 of these patients had same-day CBC data available for model prediction. The median processed volume was 15 L (range 5.9 to 19.7). The model to predict peripheral CD34 counts incorporated 3 variables from the hematology analyzer data (SD-V-EGC, SD-C-EGC, and NE#). Interestingly, the model included two variables descriptive of the morphology of early granulocytic cells. The model demonstrated an R value of 0.829 (adjusted R2 = 0.670, figure 1a). In testing the morning-of-collection model-predicted peripheral CD34, we found the model performed similarly to flow cytometry in predicting 1st collection yields. Furthermore, the CD34 prediction using the model (Figure 1 b) resulted in similar correlation with first-collection yields in patients treated with plerixafor versus patients not treated with plerixafor, in contrast to day-prior CD34 counts by flow-cytometry (Figure 1c). Two outliers for CD34 cell yield based on model predicted peripheral CD34 were identified. In one patient, the processed volume was very low (6.8 L, <5% percentile), while the second had a low mononuclear cell collection efficiency (35%) compared to the mean in this population (58.7%±23.3%). Threshold values for the model accurately identified patients appropriate for collection initiation (or plerixafor administration). Conclusion: Using data from a common, automated CBC analyzer, we developed a rapid, less-costly, and simple model to predict CD34 cell counts and 1st harvest yields. Because the measurement results can be obtained within the same clinic visit, and can be repeated with each CBC, the model is particularly useful to guide optimal use of plerixafor. We also envision that the model is useful for quality assurance of collection by identifying patients in whom cell yields were sub-optimal with respect to predicted CD34 cell counts. Additional studies to test the model in a larger population are ongoing. We propose that this model (and similarly derived models) can be implemented in clinical planning algorithms to improve the efficiency and cost of stem cell collection by apheresis. Acknowledgments: We would like to acknowledge and the nurses and staff of the apheresis unit and the stem cell and flow cytometry laboratories at the Hospital of the University of Pennsylvania for their contributions. Figure 1. Figure 1. Disclosures No relevant conflicts of interest to declare.


2006 ◽  
Vol 130 (12) ◽  
pp. 1850-1858
Author(s):  
Zahid Kaleem

Abstract Context.—Immunophenotyping has become a routine practice in the diagnosis and classification of most cases of non-Hodgkin lymphoma, and flow cytometry is often the method of choice in many laboratories. The role that flow cytometry plays, however, extends beyond just diagnosis and classification. Objective.—To review and evaluate the current roles of flow cytometry in non-Hodgkin lymphoma, to compare it with immunohistochemistry, and to discuss its potential future applications in the molecular diagnostic era. Data Sources.—The information contained herein is derived from peer-reviewed articles on the subject published in the English-language medical literature during the years 1980 to 2005 that were identified using PubMed (http://www.ncbi.nlm.nih.gov/entrez/query.fcgi, 1980–2005) search, various books and other sources on flow cytometry, and the author's personal experience of more than 10 years with flow cytometric analysis of lymphomas and leukemia using Becton-Dickinson (San Jose, Calif) and Beckman-Coulter (Miami, Fla) flow cytometers. Study Selection.—Studies were selected based on adequate material and methods, statistically significant results, and adequate clinical follow-up. Data Extraction.—The data from various sources were compared when the methods used were the same or similar and appropriate controls were included. Most of the studies employed 2-color, 3-color, or 4-color flow cytometers with antibodies from Becton-Dickinson, Beckman-Coulter, or DakoCytomation (Carpinteria, Calif). Results were evaluated from studies utilizing the same or similar techniques and flow cytometers. Only objective data analyses from relevant and useful publications were included for reporting and discussion. Data Synthesis.—Flow cytometry serves a variety of roles in the field of lymphoma/leukemia including rapid diagnosis, proper classification, staging, minimal residual disease detection, central nervous system lymphoma detection, evaluation of prognostic markers, detection of target molecules for therapies, ploidy analysis of lymphoma cell DNA, and evaluation of multidrug-resistance markers. It offers many advantages in comparison to immunohistochemistry for the same roles and provides uses that are either not possible or not preferable by immunohistochemistry such as multiparameter evaluation of single cells and detection of clonality in T cells. Conclusions.—By virtue of its ability to evaluate not only surface but also cytoplasmic and nuclear antigens, flow cytometry continues to enjoy widespread use in various capacities in lymphoma evaluation and treatment. Additional roles for flow cytometry are likely to be invented in the future and should provide distinctive uses in the molecular era.


Blood ◽  
2006 ◽  
Vol 108 (11) ◽  
pp. 5036-5036
Author(s):  
Tove Isaacson ◽  
Andrzej Jakubowiak ◽  
Lloyd Stoolman ◽  
Usha Kota ◽  
William Finn ◽  
...  

Abstract Multiparameter flow cytometry is a useful tool for comprehensive immunophenotyping of plasma cell myeloma, and has been proposed as a sensitive method for the evaluation of minimal residual disease in patients following treatment. This study aimed to assess the value of flow cytometry in quantitation of residual disease, in comparison to routine morphologic examination of first-pull bone marrow aspirate smears, in myeloma patients post-therapy. Heparinized bone marrow aspirates were obtained from 27 treated patients with plasma cell myeloma. Cells were prepared for 5-color flow cytometric analysis within 24-hours of specimen draw. Surface membrane staining with anti-CD19, CD20, CD38, CD45, CD56, and CD138 was followed by ammonium chloride lysis of red cells. Fixed and permeabilized cells were analyzed for cytoplasmic light chains to confirm clonality. Data were acquired using an FC500 flow cytometer (Beckman-Coulter), analyzed with CXP software with plasma cells isolated based on bright CD38+ or CD138+ expression. A median of 97,639 cellular events (range 14,279 to 262,508) were collected per analysis. Flow cytometric enumeration of plasma cells was compared to 500-cell differential counts of Wright-Giemsa-stained first-pull aspirate smears from the same cases. The median plasma cell count as determined by flow cytometry was 0.5% (range 0–7.9%). The median plasma cell count estimated by morphologic review was 8.0% (range 0–84.4%). Flow cytometry underestimated the plasma cell content in all but one case. Clonal plasma cells expressed CD38 and CD138 in all cases; 87.5% (21/24) coexpressed CD56, 25% (6/24) coexpressed CD45, and 4.2% (1/24) coexpressed CD19. None was positive for CD20. Although detection of minimal residual disease after therapy for acute leukemia is routinely achieved by flow cytometric analysis, successful quantitation of minimal residual disease in treated myeloma patients using flow cytometry remains limited as it usually underestimates the plasma cell content of bone marrow samples compared to routine morphology of first-pull aspirates. We have observed that this holds true for both pre-treatment and post-treatment specimens. Causes for the discrepancy may include hemodilution of second-pull aspirates used for flow cytometry, fragility and loss of plasma cells during preparation for flow cytometry, and incomplete disaggregation of plasma cells from bone marrow spicules. With improved outcome of treatments, better and more reliable methods of detection of minimal residual disease are needed for optimal prognostic stratification. We are currently validating alternative methods, which may offer more sensitivity while at the same time allow more objectivity, for assessing the amount of minimal residual disease in myeloma patients.


2006 ◽  
Vol 25 (1) ◽  
pp. 41-47 ◽  
Author(s):  
Puntipa Kwanyuen ◽  
Sam M. Witherspoon ◽  
Don R. Creech ◽  
Heidi M. Colton ◽  
J. Greg Falls ◽  
...  

Multiple methods currently exist for the assessment of peroxisome proliferation, including gene expression, enzyme activity, immunolabeling coupled with image analysis, and electron microscopy. This study describes a novel flow cytometric method to efficiently quantify peroxisome proliferation in cells from frozen livers. Frozen livers from cynomolgus monkeys treated with ciprofibrate at doses of 0, 3, 30, 150, and 400 mg/kg/day for 15 days were mechanically disaggregated using an automated dispersion method. The resulting cell suspensions were labeled using an allophycocyanin (APC)-conjugated antibody directed against peroxisomal membrane protein 70 (PMP70). Statistically significant increases in mean fluorescence intensity were observed from animals dosed at 30, 150, and 400 mg/kg/day compared to control. Parallel comparisons using electron microscopy and immunofluorescence microscopy suggest that flow cytometry may be an alternative to electron microscopy in determinations of peroxisome proliferation. Flow cytometric analysis of freshly isolated hepatocytes and frozen liver from rats treated with fenofibrate at 200 mg/kg/day for 10 days showed the flow cytometric method could detect peroxisome proliferation in both species. The research described here demonstrates the feasibility of applying flow cytometry for the detection of peroxisome proliferation.


Blood ◽  
2019 ◽  
Vol 134 (Supplement_1) ◽  
pp. 3688-3688
Author(s):  
Taha Bat ◽  
Eunice S. Wang ◽  
Joanne Becker ◽  
Orla Maguire ◽  
Hans Minderman ◽  
...  

Background:It is known that platelets interact with tumors to support malignant cell growth and stimulate epithelial to mesenchymal transition (Li, et al. "The Role of Platelets in Tumor Growth, Metastasis, and Immune Evasion", Platelets, pp. 547-561, Academic Press, 2019). P-selectin which is secreted from alpha granules has been implicated as the major perpetrator of this tumor cell and platelet communication. (Kim et al, PNAS 95(16): 9325-9330, 1998). Higher numbers of alpha granules are found in newly released young platelets from megakaryocytes, also known as pre-platelets, than mature platelets. Given their potential role in cancer metastasis, the ability to identify and isolate pre-platelets from mature plateletsforassessment of overall functionality and biology is important. Of note, identification and measurement of pre-platelets based on higher RNA content has been in clinical use for various clinical conditions for several years. Here we evaluated the feasibility of identifying and sorting pre-platelets by flow cytometric analyses in multiple platelet apheresis samples from heathy donors. Study Design and Methods Apheresis samples from adult healthy donors at Roswell Park Comprehensive Cancer Center were obtained and analyzed in accordance with an IRB approved protocol. Platelets sampled from apheresis products were collected with the use of an apheresis device known to yield a leuko-reduced platelet concentrate. All components were irradiated with 2500 cGy immediately after the collection and stored on platelet agitator at 22°C. A 4 mL aliquot was withdrawn from each bag for sorting essays.Pre-platelets were distinguished from mature platelets based on the presence of higher RNA levels. The cell permeant RNA dye TO (BD Biosciences, San Jose, CA) was used to identify pre-plapletes by flow cytometry according to published protocol (Ando et al Blood97 (4): p915-921, 2001).The optimal concentration of TO dye was determined by titration at decreasing dilutions and acquisition on a LSR-II flow cytometer (BD Biosciences, San Jose, CA). Confirmation of flow cytometry-based assay was determined by processing 5 healthy donor whole blood samples by both flow cytometry and using an XE-5000 automated hematology analyzer (Sysmex America, Mundelein, IL). The percentage of pre-platelets was measured as a percent of total platelets by both techniques. Platelet sorting was performed on 12 leuko-reduced apheresis platelet products on a FACSAria II (BD Biosciences, San Jose, CA). Platelets were identified by co-staining with CD41a. Platelet activation was assessed before and after sorting based on P-selectin (CD62P) surface expression. Flow cytometry analysis was performed using FCSExpress v6. Results: We determined that flow cytometric sorting of pre-platelets optimally required TO (0.5 µg/mL) for optimal staining for gating of pre-platelets. A two way, paired simple t test resulted in a p value of 0.09 when compared to standard gating strategy per XE-5000 automated hematology analyzer. Among all 14 samples evaluated, the percentage of preplatelet to apheresis sample pre-platelet ratio was estimated between 2.8% to 8.2%. Interestingly P-selectin ratio of pre-platelets was significantly higher than mature platelets (median: 67% vs 52%). ConclusionThis study is the first to demonstrate the feasibility of identifying and sorting pre-platelets using a novel flow cytometric method with TO staining. Isolation of these rare platelet precursor cells (pre-platelets) with known higher P-selectin expression are an essential first step to understanding the potential pre-eminent role of these cells in cancer evasion and metastasis. Disclosures Wang: Abbvie: Other: Advisory role; Kite: Other: Advisory role; Jazz: Other: Advisory role; Astellas: Other: Advisory role, Speakers Bureau; celyad: Other: Advisory role; Pfizer: Other: Advisory role, Speakers Bureau; Stemline: Other: Advisory role, Speakers Bureau; Daiichi: Other: Advisory role; Amgen: Other: Advisory role; Agios: Other: Advisory role.


2016 ◽  
Vol 60 (4) ◽  
pp. 336-343 ◽  
Author(s):  
Vinodh Pillai ◽  
David M. Dorfman

Many epithelial neoplasms can be analyzed by flow cytometry (FC), particularly from serous cavity effusion samples, using EpCAM, a cell adhesion molecule expressed on most normal epithelial cells and expressed at a higher level in most epithelial neoplasms. A simple 3-color flow cytometric panel can provide a high sensitivity and specificity compared to cytomorphology. FC provides more rapid immunophenotyping than conventional immunohistochemical staining, can identify rare malignant cells that could be missed by a cytological exam alone, and can be utilized to evaluate limited samples such as cerebrospinal fluid or fine-needle aspiration samples. Flow cytometric analysis for epithelial antigens can be combined with DNA ploidy analysis or assessment of the nucleus-to-cytoplasm ratio. Panels of flow cytometric markers are useful for the assessment of pediatric nonhematopoietic neoplasms, including neuroblastomas, primitive neuroectodermal tumors, Wilms' tumor, rhabdomyosarcomas, germ cell tumors, and hemangiopericytomas, as well as small-round-blue-cell tumors in adults, including small-cell carcinomas.


Sign in / Sign up

Export Citation Format

Share Document