scholarly journals Immunoblot Assay Using Recombinant Antigens as a Supplemental Test To Confirm the Presence of Antibodies to Trypanosoma cruzi

2007 ◽  
Vol 14 (4) ◽  
pp. 355-361 ◽  
Author(s):  
Kevin Y. Cheng ◽  
Chi-Deu Chang ◽  
Vince A. Salbilla ◽  
Louis V. Kirchhoff ◽  
David A. Leiby ◽  
...  

ABSTRACT The diagnosis of chronic Chagas' disease is generally made by detecting antibodies to Trypanosoma cruzi. Most conventional serological tests are based on lysates of whole parasites or semipurified antigen fractions from T. cruzi epimastigotes grown in culture. The occurrence of inconclusive and false-positive results has been a persistent problem with the conventional assays, and there is no universally accepted gold standard for confirmation of positive test results. We describe here an immunoblot assay for detecting antibodies to T. cruzi in which four chimeric recombinant antigens (rAgs), designated FP3, FP6, FP10, and TcF, are used as target antigens. Each of these rAgs is composed of several antigenically distinct regions and includes repetitive as well as nonrepetitive sequences. Each rAg is coated as a discrete line on a nitrocellulose strip. Assay sensitivity was assessed by testing 345 specimens known to be positive for antibodies to T. cruzi. All 345 of these samples showed two to four reactive test bands in addition to the three on-board control bands that are on each strip. Assay specificity was determined by testing 500 specimens from random U.S. blood donors, all of which gave negative results. Based on the results obtained in this study, we propose the following scheme for interpretation of test results: (i) no bands or a single test band = a negative result; (ii) two or more test bands with at least one band showing intensity of 1+ or higher = a positive result; and (iii) multiple faint test bands (±) = indeterminate result. Based on this scheme, the prototype immunoblot assay showed sensitivity of 100% (n = 345) and specificity of 100% (n = 500). Additionally, all 269 potentially cross-reacting and T. cruzi antibody-negative specimens tested negative in our immunoblot assay. The rAg-based immunoblot assay has potential as a supplemental test for confirming the presence of antibodies to T. cruzi in blood specimens and for identifying false-positive results obtained with other assays.

2021 ◽  
Vol 12 ◽  
Author(s):  
Nastya Kharlamova ◽  
Nicky Dunn ◽  
Sahl K. Bedri ◽  
Svante Jerling ◽  
Malin Almgren ◽  
...  

Patients with chronic inflammatory diseases are often treated with immunosuppressants and therefore are of particular concern during the SARS-CoV-2 pandemic. Serological tests will improve our understanding of the infection and immunity in this population, unless they tests give false positive results. The aim of this study was to evaluate the specificity of SARS-Cov-2 serological assays using samples from patients with chronic inflammatory diseases collected prior to April 2019, thus defined as negative. Samples from patients with multiple sclerosis (MS, n=10), rheumatoid arthritis (RA, n=47) with or without rheumatoid factor (RF) and/or anti-cyclic citrullinated peptide antibodies (anti-CCP2) and systemic lupus erythematosus (SLE, n=10) with or without RF, were analyzed for SARS-CoV-2 antibodies using 17 commercially available lateral flow assays (LFA), two ELISA kits and one in-house developed IgG multiplex bead-based assay. Six LFA and the in-house validated IgG assay correctly produced negative results for all samples. However, the majority of assays (n=13), gave false positive signal for samples from patients with RA and SLE. This was most notable in samples from RF positive RA patients. No false positive samples were detected in any assay using samples from patients with MS. Poor specificity of commercial serological assays could possibly be, at least partly, due to interfering antibodies in samples from patients with chronic inflammatory diseases. For these patients, the risk of false positivity should be considered when interpreting results of the SARS-CoV-2 serological assays.


2018 ◽  
Vol 72 ◽  
pp. 1162-1178
Author(s):  
Aleksandra Lewandowicz-Uszyńska ◽  
Piotr Naporowski ◽  
Gerard Pasternak ◽  
Danuta Witkowska

The human immune system’s response to infection is closely related with the type of pathogen. First, a rapid, metabolically inexpensive and non-specific innate immunity is induced, then a specific acquired immunity is activated. In bacterial infections caused by intracellular pathogens, the main role is played by cellular response. In infections caused by bacterial extracellular pathogens, a crucial role is played by antibodies. The clinical symptoms of bacterial and viral infections very often are similar, which is why diagnosing them based only on medical history and physical examination is insufficient. To identify the etiological factors of infections differentiating media, biochemical tests, molecular methods and serological tests are used. The detection of microorganisms or their genetic material can be performed within a short time after the occurrence of an infection. The detection of antibodies is possible only in the appropriate time called the serological window. In a serological diagnostic of infections there are problems with an appropriate interpretation of obtained results. Cross-reactivity can give false positive results for the diagnosis of Chlamydophila pneumonia infection. The problem with the detection of Borrelia burgdorferi infection can be caused by a simultaneous coinfection with different spirochetes, syphilis, mononucleosis or HIV. In serological diagnostics of bacterial infections, the administration of antibiotics to patients before taking serum samples can be responsible for false negative results. Another reason for such results can be a weak humoral response in infected patients. In viral infections, false positive results can be caused by a coinfection of different viruses, especially from the same family or by bacterial or protozoal coinfections or by autoimmune diseases. False-negative results in viral infections often are caused by the early phase of an infection. To properly recognize an etiological factor of infection it is necessary to use an appropriate method, precision of test and collect samples at the appropriate time.


2020 ◽  
Author(s):  
Nastya Kharlamova ◽  
Nicky Dunn ◽  
Sahl K Bedri ◽  
Svante Jerling ◽  
Malin Almgren ◽  
...  

AbstractObjectivesPatients with chronic inflammatory diseases are often treated with immunosuppressants and therefore are of particular concern during the SARS-CoV-2 pandemic. Serological tests will improve our understanding of the infection and immunity in this population, unless the tests give false positive results. The aim of this study was to evaluate the specificity of SARS-Cov-2 serological assays with samples from patients with chronic inflammatory diseases collected before April 2019, thus defined as negative.MethodsSamples from patients with multiple sclerosis (MS, n=10), rheumatoid arthritis (RA, n=47) with or without rheumatoid factor (RF) and/or anti-cyclic citrullinated peptide antibodies (anti-CCP2) and RF +/- systemic lupus erythematosus (SLE, n=10), were tested with 17 commercially available lateral flow assays (LFA), two ELISA kits and one in-house developed multiplex bead-based assay.ResultsSix LFA and the in-house IgG assay gave the correct negative results for all samples. However, the majority of assays (n=13), gave false positive signal with samples from patients with RA and SLE. This was most notable in RF positive RA samples. MS samples did not give any false positive in any of the assays.ConclusionThe majority of the verified serological assays were sensitive to interfering antibodies in samples from patients with chronic inflammatory diseases and therefore may have poor specificity in this context. For these patients, the risk of false positivity should be considered when interpreting results of the SARS-CoV-2 serological assays.


2020 ◽  
Vol 9 (5) ◽  
pp. 236-241
Author(s):  
Rui Li ◽  
Chi Wang ◽  
Xiao-Jian Ji ◽  
Qing-Yuan Zheng ◽  
Xiang Li ◽  
...  

Aims The purpose of this study was to validate our hypothesis that centrifugation may eliminate false-positive leucocyte esterase (LE) strip test results caused by autoimmune diseases in the diagnosis of knee infection. Methods Between January 2016 and May 2019, 83 cases, including 33 cases of septic arthritis and 50 cases of aseptic arthritis, were enrolled in this study. To further validate our hypothesis, another 34 cases of inflammatory arthritis from the Department of Rheumatology of our institution were also included. After aspiration, one drop of synovial fluid was applied to LE strips before and after centrifugation. The results were recorded after approximately three minutes according to the different colour grades on the colour chart. The differences of LE results between each cohort were analyzed. Results Before centrifugation, 46% (23/50) of the LE strip tests in the aseptic arthritis group were false-positives. Most of the false-positive results were due to inflammatory arthritis; after centrifugation, 78.3% (18/23) of the tests yielded negative results. Similar results were observed in cases from the Department of Rheumatology. The sensitivity of the centrifuged LE strip test was 0.818 (0.639 to 0.924), which is still an acceptable level compared with the uncentrifuged results, which yielded a sensitivity of 0.909 (0.745 to 0.976). However, the specificity was increased from 0.540 (0.395 to 0.679) to 0.900 (0.774 to 0.963) after centrifugation. Conclusion Although inflammatory arthritis can yield a false-positive LE strip test result in the diagnosis of knee infection, centrifugation may eliminate these false-positive results. Cite this article: Bone Joint Res. 2020;9(5):236–241.


1974 ◽  
Vol 31 (02) ◽  
pp. 273-278
Author(s):  
Kenneth K Wu ◽  
John C Hoak ◽  
Robert W Barnes ◽  
Stuart L Frankel

SummaryIn order to evaluate its daily variability and reliability, impedance phlebography was performed daily or on alternate days on 61 patients with deep vein thrombosis, of whom 47 also had 125I-fibrinogen uptake tests and 22 had radiographic venography. The results showed that impedance phlebography was highly variable and poorly reliable. False positive results were noted in 8 limbs (18%) and false negative results in 3 limbs (7%). Despite its being simple, rapid and noninvasive, its clinical usefulness is doubtful when performed according to the original method.


PEDIATRICS ◽  
1987 ◽  
Vol 79 (2) ◽  
pp. 203-205
Author(s):  
Mendel Tuchman ◽  
Margaret L. R. Ramnaraine ◽  
William G. Woods ◽  
William Krivit

During the last 3 years, random urine samples from 408 patients were tested for elevated homovanillic acid (HVA) and vanillylmandelic acid (VMA) levels to rule out the diagnosis of neuroblastoma. Thirty-seven of these patients had elevated HVA and/or VMA levels, and neuroblastoma was subsequently diagnosed. In three additional patients with negative test results (normal HVA and VMA levels), tumors were subsequently diagnosed (false-negative rate of 7.5%). Ten percent of the patients with neuroblastoma had normal HVA and 27.5% had normal VMA levels at the time of diagnosis. Only one patient (2.5%) with neuroblastoma had elevated VMA levels in the presence of normal HVA levels. More than 60% of the patients with neuroblastoma had urinary HVA and/or VMA levels higher than twice the upper limit of normal. No false-positive results were encountered. Age and stage distributions of the patients are shown, and the significance of the results is discussed.


2002 ◽  
Vol 23 (6) ◽  
pp. 335-337 ◽  
Author(s):  
Cassandra D. Salgado ◽  
Heidi L. Flanagan ◽  
Doris M. Haverstick ◽  
Barry M. Farr

Background:Occupational exposure to human immunodeficiency virus (HIV) is an important threat to healthcare workers. Centers for Disease Control and Prevention guidelines recommend prompt institution of prophylaxis. This requires (1) immediate prophylaxis after exposure, pending test results that may take more than 24 hours in many hospitals; or (2) performance of a rapid test. The Single Use Diagnostic System (SUDS)® HIV-1 Test is used to screen rapidly for antibodies to HIV type 1 in plasma or serum, with a reported sensitivity of more than 99.9%. We used this test from January 1999 until September 2000, when it was withdrawn from the market following reports claiming a high rate of false-positive results.Methods:We reviewed the results of postexposure HIV testing during 21 months.Results:A total of 884 SUDS tests were performed on source patients after occupational exposures (883 negative results, 1 reactive result). The results of repeat SUDS testing on the reactive specimen were also reactive, but the results of enzyme immunoassay and Western blot testing were negative. A new specimen from the same patient showed a negative result on SUDS testing. This suggested a specificity of 99.9%. In the 4 months after SUDS testing was suspended, there was 1 false-positive result on enzyme immunoassay for 1 of 132 source patients (presumed specificity, 99.2%).Conclusion:Use of the SUDS test facilitated rapid and accurate evaluation of source specimens, obviating unnecessary prophylaxis.


PEDIATRICS ◽  
1996 ◽  
Vol 98 (1) ◽  
pp. 41-44
Author(s):  
Judy G. Saslow ◽  
Ernest M. Post ◽  
Carol A. Southard

Objective. As neonatal discharge before 24 hours of life becomes commonplace, the rejection of congenital hypothyroidism (CH) screening specimens obtained too early has created the need for numerous additional tests. We sought to determine whether the specimens obtained before 24 hours could be used safely. Methods. During a 31-day period we measured thyrotropin in all thyroid-screening specimens that had been obtained before 24 hours. We also examined the early specimens from every infant diagnosed in New Jersey with CH during 1993 or 1994. Results. Among the 663 specimens, those obtained at or before 12 hours and those from infants with birth weights less than 2500 g had too many low thyroxine results to be useful. Among the 515 specimens obtained at more than 12 to 24 hours from newborns weighing 2500 g or more, 37 (7%) had low thyroxine levels and 12 (2.3%) had thyrotropin levels of 20 µIU/mL (mU/L) or higher. Four hundred seventy-one of the 515 infants had subsequent specimens obtained at more than 24 hours, and none of the results were abnormal. There was no child weighing more than or equal to 2500 g who was diagnosed with CH in 1993 and 1994 whose specimen obtained at 24 hours or less was normal. Conclusions. Accepting specimens obtained at more than 12 to 24 hours from infants weighing 2500 g or more would have resulted in more than the usual number of false-positive results but no false-negative results. This would have decreased the requests for additional specimens by more than 90%.


1990 ◽  
Vol 36 (12) ◽  
pp. 2053-2056 ◽  
Author(s):  
T Fonong ◽  
S M Evans ◽  
H A Homburger

Abstract We developed rapid 24-h immunoblot assays for detecting autoantibodies to Scl 70 and Jo 1 antigens in serum. In comparative studies, we evaluated the analytical sensitivity of the immunoblot assays and commercial immunodiffusion assays for anti-Scl 70 and anti-Jo 1 autoantibodies with the use of positive control sera, and compared the frequencies of positive and negative results in a group of 116 sera, including specimens from 34 healthy controls and 82 patients with various connective-tissue diseases. The immunoblot assays were greater than 100-fold more sensitive than immunodiffusion for detecting both autoantibodies. Despite greater analytical sensitivity, there were no false-positive results by the immunoblot assay for anti-Scl 70 or anti-Jo 1 autoantibodies in sera from either the controls or the patients. The diagnostic sensitivity of the immunoblot assay for anti-Scl 70 autoantibodies in patients with scleroderma was greater than that of the immunodiffusion assay, 70% vs 20%, and was equivalent in patients with polymyositis, 43%. We conclude that rapid immunoblot assays for anti-Scl 70 and anti-Jo 1 autoantibodies are superior to immunodiffusion assays for clinical use and are suitable for routine use in the clinical laboratory.


Medicina ◽  
2013 ◽  
Vol 49 (7) ◽  
pp. 52 ◽  
Author(s):  
Talgat Maimakov ◽  
Laura Sadykova ◽  
Zhanna Kalmataeva ◽  
Kural Kurakpaev ◽  
Kastytis Šmigelskas

Background and Objective. Since 1990, the tuberculosis incidence rate in Eastern Europe and post-Soviet republics has been increasing in many countries including Kazakhstan. This problem is particularly important in Kazakhstan regions with limited financial resources, among them – in South Kazakhstan province. The aim of this study was to investigate the main clinical and antibiotic-related economic aspects of tuberculosis treatment in South Kazakhstan province. Material and Methods. In total, 502 patients participated in the study. They were hospitalized to the tuberculosis dispensary of Sayram district (South Kazakhstan province) in 2007–2013. Statistical analysis included logistic regression for better treatment outcomes and analysis of antibiotic treatment costs. Results. Two-thirds of patients had infiltrative tuberculosis (67%). Positive treatment outcomes were determined in 85% of cases. The patients were mostly treated with cycloserine, protionamide, capreomycin, and ofloxacin. The majority of antibiotic costs were related to the treatment with capreomycin. In case of the positive results of the test for Mycobacterium tuberculosis, antibiotic expenses were almost 3 times greater than in case of negative test results (P<0.001). Conclusions. The majority of patients had extensively drug-resistant tuberculosis. The negative results of the test for Mycobacterium tuberculosis at discharge were not related to pretreatment factors. Antibiotic-related costs were significantly higher in case of the positive results of the test of Mycobacterium tuberculosis, but were not associated with gender, residence place, hospitalization recurrence, or main blood test results before treatment.


Sign in / Sign up

Export Citation Format

Share Document