scholarly journals Clinical Use of Capillary PCR To DiagnoseMycoplasma Pneumonia

2000 ◽  
Vol 38 (4) ◽  
pp. 1382-1384 ◽  
Author(s):  
Junichi Honda ◽  
Takafumi Yano ◽  
Mikako Kusaba ◽  
Junko Yonemitsu ◽  
Hiromoto Kitajima ◽  
...  

In the present study, serologic data were compared with data obtained by capillary PCR to establish the efficacy of capillary PCR for the determination of Mycoplasma infection in samples obtained from throat swabs, bronchoalveolar lavage fluids (BALF), and sputum of patients with Mycoplasma pneumonia. We performed PCR analysis for Mycoplasma DNA on a total of 325 samples from 197 patients with community-acquired pneumonia and in whom Mycoplasma pneumonia was suspected. There were 68 PCR-positive specimens. Review of the differences in PCR positivity rates based on the site of specimen collection showed the highest rate of detection (28.6%) from throat swabs. From among the 31 patients with significantly elevated titers of serum Mycoplasmaantibodies, the PCR results were positive for 25 patients. Thus, capillary PCR had a sensitivity of 80.6% (25 of 31). Five of the six false-negative results were from throat swab specimens. Moreover, testing (PCR) had been performed only once for these five patients with false-negative results. From among the PCR-positive findings from BALF specimens, there were no false-positive results. BALF specimens were very useful, except for the technical procedures and increased patient burden required to obtain these specimens. We suggest that the use of throat swab specimens in capillary PCR is much more suitable for diagnosing Mycoplasma pneumonia in routine clinical practice; however, careful throat swab specimen collection and an increase in the number of times that the PCR is performed are necessary to reduce the rate of false-negative results.

1974 ◽  
Vol 31 (02) ◽  
pp. 273-278
Author(s):  
Kenneth K Wu ◽  
John C Hoak ◽  
Robert W Barnes ◽  
Stuart L Frankel

SummaryIn order to evaluate its daily variability and reliability, impedance phlebography was performed daily or on alternate days on 61 patients with deep vein thrombosis, of whom 47 also had 125I-fibrinogen uptake tests and 22 had radiographic venography. The results showed that impedance phlebography was highly variable and poorly reliable. False positive results were noted in 8 limbs (18%) and false negative results in 3 limbs (7%). Despite its being simple, rapid and noninvasive, its clinical usefulness is doubtful when performed according to the original method.


PEDIATRICS ◽  
1996 ◽  
Vol 98 (1) ◽  
pp. 41-44
Author(s):  
Judy G. Saslow ◽  
Ernest M. Post ◽  
Carol A. Southard

Objective. As neonatal discharge before 24 hours of life becomes commonplace, the rejection of congenital hypothyroidism (CH) screening specimens obtained too early has created the need for numerous additional tests. We sought to determine whether the specimens obtained before 24 hours could be used safely. Methods. During a 31-day period we measured thyrotropin in all thyroid-screening specimens that had been obtained before 24 hours. We also examined the early specimens from every infant diagnosed in New Jersey with CH during 1993 or 1994. Results. Among the 663 specimens, those obtained at or before 12 hours and those from infants with birth weights less than 2500 g had too many low thyroxine results to be useful. Among the 515 specimens obtained at more than 12 to 24 hours from newborns weighing 2500 g or more, 37 (7%) had low thyroxine levels and 12 (2.3%) had thyrotropin levels of 20 µIU/mL (mU/L) or higher. Four hundred seventy-one of the 515 infants had subsequent specimens obtained at more than 24 hours, and none of the results were abnormal. There was no child weighing more than or equal to 2500 g who was diagnosed with CH in 1993 and 1994 whose specimen obtained at 24 hours or less was normal. Conclusions. Accepting specimens obtained at more than 12 to 24 hours from infants weighing 2500 g or more would have resulted in more than the usual number of false-positive results but no false-negative results. This would have decreased the requests for additional specimens by more than 90%.


2006 ◽  
Vol 89 (2) ◽  
pp. 462-468 ◽  
Author(s):  
Arjon J van Hengel ◽  
Claudia Capelletti ◽  
Marcel Brohee ◽  
Elke Anklam ◽  
M-C S Baumgartner ◽  
...  

Abstract Results are reported for an interlaboratory validation study of 2 commercially available lateral flow devices (dipstick tests) designed to detect peanut residues in food matrixes. The test samples used in this study were cookies containing peanuts at 7 different concentrations in the range of 030 mg peanuts/kg food matrix. The test samples with sufficient and proven homogeneity were prepared in our laboratory. The analyses of the samples (5 times per level by each laboratory) were performed by 18 laboratories worldwide, which submitted a total of 1260 analytical results. One laboratory was found to be an outlier for one of the test kits. In general, both test kits performed well. However, some false-negative results were reported for all matrixes containing <21 mg peanuts/kg cookie. It must be stressed that the test kits were challenged beyond their cut-off limits (5 mg/kg, depending on the food matrix). One test kit showed fewer false-negative results, but it led to some false-positive results for the blank materials. The sensitivity of the dipstick tests approaches that achieved with enzyme-linked immunosorbent assays.


2011 ◽  
Vol 29 (22) ◽  
pp. 2978-2984 ◽  
Author(s):  
Allison W. Welsh ◽  
Christopher B. Moeder ◽  
Sudha Kumar ◽  
Peter Gershkovich ◽  
Elaine T. Alarid ◽  
...  

Purpose Recent misclassification (false negative) incidents have raised awareness concerning limitations of immunohistochemistry (IHC) in assessment of estrogen receptor (ER) in breast cancer. Here we define a new method for standardization of ER measurement and then examine both change in percentage and threshold of intensity (immunoreactivity) to assess sources for test discordance. Methods An assay was developed to quantify ER by using a control tissue microarray (TMA) and a series of cell lines in which ER immunoreactivity was analyzed by quantitative immunoblotting in parallel with the automated quantitative analysis (AQUA) method of quantitative immunofluorescence (QIF). The assay was used to assess the ER protein expression threshold in two independent retrospective cohorts from Yale and was compared with traditional methods. Results Two methods of analysis showed that change in percentage of positive cells from 10% to 1% did not significantly affect the overall number of ER-positive patients. The standardized assay for ER on two Yale TMA cohorts showed that 67.9% and 82.5% of the patients were above the 2-pg/μg immunoreactivity threshold. We found 9.1% and 19.7% of the patients to be QIF-positive/IHC-negative, and 4.0% and 0.4% to be QIF-negative/IHC-positive for a total of 13.1% and 20.1% discrepant cases when compared with pathologists' judgment of threshold. Assessment of survival for both cohorts showed that patients who were QIF-positive/pathologist-negative had outcomes similar to those of patients who had positive results for both assays. Conclusion Assessment of intensity threshold by using a quantitative, standardized assay on two independent cohorts suggests discordance in the 10% to 20% range with current IHC methods, in which patients with discrepant results have prognostic outcomes similar to ER-positive patients with concordant results.


2009 ◽  
Vol 55 (7) ◽  
pp. 1389-1394 ◽  
Author(s):  
Ann M Gronowski ◽  
Mark Cervinski ◽  
Ulf-Håkan Stenman ◽  
Alison Woodworth ◽  
Lori Ashby ◽  
...  

Abstract Background: During pregnancy, human chorionic gonadotropin (hCG) immunoreactivity in urine consists of intact hCG as well as a number of hCG variants including the core fragment of hCGβ (hCGβcf). We identified 3 urine specimens with apparent false-negative results using the OSOM® hCG Combo Test (Genzyme Diagnostics) qualitative hCG device and sought to determine whether an excess of 1 of the fragments or variants might be the cause of the interference. Methods: We measured concentrations of hCG variants in the urine from 3 patients with apparent false-negative hCG results. Purified hCG variants were added to urines positive for hCG and tested using the OSOM, ICON® 25 hCG (Beckman Coulter), and hCG Combo SP® Brand (Cardinal Health) devices. Results: Dilution of these 3 urine samples resulted in positive results on the OSOM device. Quantification of hCG variants in each of the 3 patient urine specimens demonstrated that hCGβcf occurred in molar excess of intact hCG. Addition of purified hCGβcf to hCG-positive urines caused false-negative hCG results using the OSOM and ICON qualitative urine hCG devices. Conclusions: Increased concentrations of hCGβcf can cause false-negative results on the OSOM and ICON qualitative urine hCG devices. .


2018 ◽  
Vol 72 ◽  
pp. 1162-1178
Author(s):  
Aleksandra Lewandowicz-Uszyńska ◽  
Piotr Naporowski ◽  
Gerard Pasternak ◽  
Danuta Witkowska

The human immune system’s response to infection is closely related with the type of pathogen. First, a rapid, metabolically inexpensive and non-specific innate immunity is induced, then a specific acquired immunity is activated. In bacterial infections caused by intracellular pathogens, the main role is played by cellular response. In infections caused by bacterial extracellular pathogens, a crucial role is played by antibodies. The clinical symptoms of bacterial and viral infections very often are similar, which is why diagnosing them based only on medical history and physical examination is insufficient. To identify the etiological factors of infections differentiating media, biochemical tests, molecular methods and serological tests are used. The detection of microorganisms or their genetic material can be performed within a short time after the occurrence of an infection. The detection of antibodies is possible only in the appropriate time called the serological window. In a serological diagnostic of infections there are problems with an appropriate interpretation of obtained results. Cross-reactivity can give false positive results for the diagnosis of Chlamydophila pneumonia infection. The problem with the detection of Borrelia burgdorferi infection can be caused by a simultaneous coinfection with different spirochetes, syphilis, mononucleosis or HIV. In serological diagnostics of bacterial infections, the administration of antibiotics to patients before taking serum samples can be responsible for false negative results. Another reason for such results can be a weak humoral response in infected patients. In viral infections, false positive results can be caused by a coinfection of different viruses, especially from the same family or by bacterial or protozoal coinfections or by autoimmune diseases. False-negative results in viral infections often are caused by the early phase of an infection. To properly recognize an etiological factor of infection it is necessary to use an appropriate method, precision of test and collect samples at the appropriate time.


1986 ◽  
Vol 49 (2) ◽  
pp. 92-98 ◽  
Author(s):  
GEORGE F. IBRAHIM ◽  
MARY J. LYONS ◽  
RETA A. WALKER ◽  
GRAHAM H. FLEET

A standard cultural method, radioimmunometric (RIMA) and enzyme immunometric (EIMA) assays were compared for detection of salmonellae in 235 food samples. The immunoassays used titanous hydroxide as the solid-phase, commercial Spicer-Edwards salmonella polyvalent H antisera (SEA) or pooled antisera produced against 10 salmonella flagellins (PFA). Nineteen food samples were positive for Salmonella by the standard cultural method. These as well as one additional sample were also positive for Salmonella by RIMA and EIMA. No false-negative results were obtained from the immunoassays using PFA, whereas two false-negative results were observed when SEA was used. The incidence of false-positive results when SEA and PFA were used were, respectively, 3.0 and 0.9% with RIMA and 2.6 and 0.9% with EIMA. The immunoassays were also able to detect 77 Salmonella serotypes when grown alone or in association with other species of Enterobacteriaceae, in mannitol selenite cystine broth. Both immunoassays performed reliably on enrichment cultures stored under refrigeration for up to 9 d. Also, of 6 non-motile salmonellae, 5 were detectable by the immunoassays. The immunoassays were simple, rapid and cost-efficient.


Author(s):  
GIORGI ADEISHVILI ◽  
MIKHEIL SHAVDIA ◽  
DAVID TABAGARI

In our opinion, the obtained results show that the level of UBC cytokeratin determined in urine reflects the destruction of tissue by the tumor to a greater extent with deep invasion and with large tumor sizes. We believe that a decrease in the sensitivity of the UBC test in detecting recurrence in patients after TUR, in comparison with the sensitivity of the UBC test in patients with BC prior to treatment, is associated with an initial level of cytodestruction in the relapse of BC. The level of serum cytokeratin TPA largely reflects the onset of metabolic changes in the tumor focus. It is the combination of UBC + TPA tests that gives rise to true-positive results and a reduction in false-negative results, which increases the sensitivity of the method.


Sign in / Sign up

Export Citation Format

Share Document