scholarly journals Changes in Skin Surface Temperature at An Acupuncture Point with Moxibustion

2013 ◽  
Vol 31 (2) ◽  
pp. 195-201 ◽  
Author(s):  
Li-Mei Lin ◽  
Shu-Fang Wang ◽  
Ru-Ping Lee ◽  
Bang-Gee Hsu ◽  
Nu-Man Tsai ◽  
...  

Objective This study evaluates the thermographic changes associated with moxa burner moxibustion at the SP6 acupuncture point to establish an appropriate, safe distance of efficacy for moxibustion. Methods Baseline temperature changes using a moxa burner were obtained for a paper substrate at various distances and times, and the tested with volunteers in a pilot study. A single-group trial was then conducted with 36 healthy women to monitor temperature changes on the body surface at the acupuncture point (SP6). Results Based on the temperature changes seen for the paper substrate and in the pilot study, a distance of 3 cm was chosen as the intervention distance. Moxibustion significantly increased the SP6 point skin surface temperature, with a peak increase of 11°C at 4 min (p <0.001). This study also found that during moxibustion the temperature of the moxa burner's rubber layer and moxa cautery were 56.9±0.9°C and 65.8±1.2°C, as compared to baseline values of 35.1°C and 43.8°C (p<0.001). Conclusions We determined 3 cm was a safe distance between the moxa burner and acupuncture point. Moxibustion can increase the skin surface temperature at the SP6 point. This data will aid traditional Chinese medicine (TCM) practitioners in gauging safer treatment distances when using moxibustion treatments.

2021 ◽  
Vol 30 (8) ◽  
pp. 632-641
Author(s):  
Sumiati Tarigan ◽  
Saldy Yusuf ◽  
Yuliana Syam

Objective: This study aimed to evaluate the interface pressure and skin surface temperature in relation to the incidence of pressure injury (PI) using three different turning schedules. Method: This was a pilot study with a three-armed randomised clinical trial design. Participants at risk of PI and treated in the high dependency care unit in a regional hospital in Makassar, Indonesia participated in this study. Patients were repositioned at three different turning schedules (two-, three- and four-hourly intervals). Interface pressure measurement and skin surface temperature were measured between 14:00 and 18:00 every three days. The incidence of PI was assessed during the two-week observation period. Results: A total of 44 participants took part in the study. A one-way ANOVA test revealed no difference in interface pressure among the three different turning schedule groups within two weeks of observations: day zero, p=0.56; day four, p=0.95; day seven, p=0.56; day 10, p=0.63; and day 14, p=0.92. Although the average periumbilical temperature and skin surface temperature were not significant (p>0.05), comparison between these observation sites was significant on all observation days (p<0.05). Regarding the incidence of PI, the proportional hazard test for the development of PI in the three groups was considered not different (hazard ratio: 1.46, 95% confidence interval: 0.43–4.87, p=0.54). Conclusion: No difference in interface pressure and incidence of PI on the three turning schedules was observed; however, there was a potential increase in skin surface temperature in comparison with periumbilical temperature for all three turning schedules.


2020 ◽  
Vol 39 (1) ◽  
Author(s):  
Inaho Shishido ◽  
Issei Konya ◽  
Rika Yano

Abstract Background Bed baths are a daily nursing activity to maintain patients’ hygiene. Those may provide not only comfort but also relaxation. Notably, applying a hot towel to the skin for 10 s (AHT10s) during bed baths helped to reduce the risk of skin tears and provided comfort and warmth in previous studies. However, it is still unclear whether autonomic nervous system is affected by bed baths. Thus, this study investigated the effect on the autonomic nervous activity of applying hot towels for 10 s to the back during bed baths. Methods This crossover study had 50 participants (25 men and women each; average age 22.2 ± 1.6 years; average body mass index 21.4 ± 2.2 kg/m2) who took bed baths with and without (control condition: CON) AHT10s on their back. Skin temperature, heart rate variability (HRV), and blood pressure (BP) were measured. Subjective evaluations and the State-Trait Anxiety Inventory in Japanese were also performed. Results A significant interaction of time and bed bath type on skin surface temperature was observed (p < .001). Regarding the means of skin surface temperature at each measurement time point, those for AHT10s were significantly higher than those for CON. Although the total state-anxiety score significantly decreased in both the bed bath types after intervention, the mean values of comfort and warmth were higher for bed baths with AHT10s than for CON (p < .05) during bed baths; AHT10s was significantly higher in warmth than CON after 15 min (p = .032). The interaction and main effects of time on HRV and BP and that of bed bath type were not significant. Conclusion Bed baths that involved AHT10s caused participants to maintain a higher skin temperature and warmer feeling than under the wiping-only condition; they also provided comfort during the interventions. However, the bed baths with AHT10s did not allow participants to reach a relaxed state; moreover, there was no change in autonomic nerve activity. This may be due to participants’ increased anxiety from skin exposure and the intervention being limited to one part of the body.


2006 ◽  
Vol 34 (7) ◽  
pp. 1182-1189 ◽  
Author(s):  
Dean A. Pollina ◽  
Andrew B. Dollins ◽  
Stuart M. Senter ◽  
Troy E. Brown ◽  
Ioannis Pavlidis ◽  
...  

2018 ◽  
Vol 85 (2) ◽  
pp. 201-203 ◽  
Author(s):  
Chunhe Yang ◽  
Gan Li ◽  
Xiaojun Zhang ◽  
Xianhong Gu

The objectives of the research reported in this Research Communication were to compare the variation of hind quarter skin surface temperature pre- and post- milking in dairy cows and to determine the optimal time to capture images by infrared thermography for improving the sensitivity and specificity of mastitis detection in dairy cows. Hind quarter infrared images of 102 Holstein dairy cows were captured from the caudal view by an infrared camera pre-milking and post-milking. The udder skin surface temperature was measured with the help of the image processing software. No significant difference was found between the left and right quarter skin surface temperature pre- and post- milking. The hind quarter skin surface temperature pre-milking was not significantly influenced by milk yield, but exhibited a rising trend along with the increase of milk yield. The hind quarter skin surface temperature post-milking was significantly influenced by milk yield. This leads us to conclude that the sensitivity and specificity of IRT in mastitis detection may be influenced by milk yield and it may be better to capture the infrared images of cow udders pre-milking.


Sign in / Sign up

Export Citation Format

Share Document