scholarly journals MRI-based 3D retinal shape determination

2021 ◽  
Vol 6 (1) ◽  
pp. e000855
Author(s):  
Luc van Vught ◽  
Denis P Shamonin ◽  
Gregorius P M Luyten ◽  
Berend C Stoel ◽  
Jan-Willem M Beenakker

ObjectiveTo establish a good method to determine the retinal shape from MRI using three-dimensional (3D) ellipsoids as well as evaluate its reproducibility.Methods and analysisThe left eyes of 31 volunteers were imaged using high-resolution ocular MRI. The 3D MR-images were segmented and ellipsoids were fitted to the resulting contours. The dependency of the resulting ellipsoid parameters on the evaluated fraction of the retinal contour was assessed by fitting ellipsoids to 41 different fractions. Furthermore, the reproducibility of the complete procedure was evaluated in four subjects. Finally, a comparison with conventional two-dimensional (2D) methods was made.ResultsThe mean distance between the fitted ellipsoids and the segmented retinal contour was 0.03±0.01 mm (mean±SD) for the central retina and 0.13±0.03 mm for the peripheral retina. For the central retina, the resulting ellipsoid radii were 12.9±0.9, 13.7±1.5 and 12.2±1.2 mm along the horizontal, vertical and central axes. For the peripheral retina, these radii decreased to 11.9±0.6, 11.6±0.4 and 10.4±0.7 mm, which was accompanied by a mean 1.8 mm posterior shift of the ellipsoid centre. The reproducibility of the ellipsoid fitting was 0.3±1.2 mm for the central retina and 0.0±0.1 mm for the peripheral retina. When 2D methods were used to fit the peripheral retina, the fitted radii differed a mean 0.1±0.1 mm from the 3D method.ConclusionAn accurate and reproducible determination of the 3D retinal shape based on MRI is provided together with 2D alternatives, enabling wider use of this method in the field of ophthalmology.

1999 ◽  
Vol 07 (02) ◽  
pp. 111-132 ◽  
Author(s):  
YONGZHI XU

This paper presents theoretical and computational results from our research on inverse scattering problems for acoustic waves in ocean environments. In particular, we discuss the determination of a three-dimensional (3-D) distributed inhomogeneity in a two-layered waveguide from scattered sound and the shape determination of an object in a stratified medium. Numerical examples are presented.


2021 ◽  
pp. 175857322110017
Author(s):  
Adrien Jacquot ◽  
Marc-Olivier Gauci ◽  
Manuel Urvoy ◽  
François Boux de Casson ◽  
Julien Berhouet ◽  
...  

Background The aim of our study was to evaluate the accuracy of manual determination of the three key points defining the anatomical plane of the scapula, which conditions the reliability of planning software programs based on manual method. Method We included 82 scapula computed tomography scans (56 pathologic and 26 normal glenoid), excluding truncation and major three-dimensional artifact. Four observers independently picked the three key points for each case. Inter- and intra-observer agreement was calculated for each point, using the intraclass correlation method. The mean error (mm) between the observers was calculated as the diameter of the smallest sphere including the four chosen positions. Results Lower inter-observer agreement was found for the trigonum superoinferior position and for the glenoid center anteroposterior position. The mean positioning error between the four observers was 6.9 mm for the trigonum point, and error greater than 10 mm was recorded in 25% of the cases. The mean positioning error was 3.5 mm for the glenoid center in altered glenoid, compared to 1.8 mm for normal glenoid. Discussion Manual determination of an anatomical plane of the scapula suffers from inaccuracy especially due to the variability in trigonum picking, and in a lesser extent, to the variability of glenoid center picking in altered glenoid.


2007 ◽  
Vol 103 (3) ◽  
pp. 895-902 ◽  
Author(s):  
Andriy I. Batchinsky ◽  
William B. Weiss ◽  
Bryan S. Jordan ◽  
Edward J. Dick ◽  
David A. Cancelada ◽  
...  

Ventilation-perfusion changes after right-sided pulmonary contusion (PC) in swine were investigated by means of the multiple inert gas elimination technique (MIGET). Anesthetized swine (injury, n = 8; control, n = 6) sustained a right-chest PC by a captive-bolt apparatus. This was followed by a 12-ml/kg hemorrhage, resuscitation, and reinfusion of shed blood. MIGET and thoracic computed tomography (CT) were performed before and 6 h after injury. Three-dimensional CT scan reconstruction enabled determination of the combined fractional volume of poorly aerated and non-aerated lung tissue (VOL), and the mean gray-scale density (MGSD). Six hours after PC in injured animals, PaO2 decreased from 234.9 ± 5.1 to 113.9 ± 13.0 mmHg. Shunt (QS) increased (2.7 ± 0.4 to 12.3 ± 2.2%) at the expense of blood flow to normal ventilation/perfusion compartments (97.1 ± 0.4 to 87.4 ± 2.2%). Dead space ventilation (VD/VT) increased (58.7 ± 1.7% to 67.2 ± 1.2%). MGSD increased (−696.7 ± 6.1 to −565.0 ± 24.3 Hounsfield units), as did VOL (4.3 ± 0.5 to 33.5 ± 3.2%). Multivariate linear regression of MGSD, VOL, VD/VT, and QS vs. PaO2 retained VOL and QS ( r2 = .835) as independent covariates of PaO2. An increase in QS characterizes lung failure 6 h after pulmonary contusion; QS and VOL correlate independently with PaO2.


Author(s):  
M. Boublik ◽  
W. Hellmann ◽  
F. Jenkins

The present knowledge of the three-dimensional structure of ribosomes is far too limited to enable a complete understanding of the various roles which ribosomes play in protein biosynthesis. The spatial arrangement of proteins and ribonuclec acids in ribosomes can be analysed in many ways. Determination of binding sites for individual proteins on ribonuclec acid and locations of the mutual positions of proteins on the ribosome using labeling with fluorescent dyes, cross-linking reagents, neutron-diffraction or antibodies against ribosomal proteins seem to be most successful approaches. Structure and function of ribosomes can be correlated be depleting the complete ribosomes of some proteins to the functionally inactive core and by subsequent partial reconstitution in order to regain active ribosomal particles.


1996 ◽  
Vol 75 (05) ◽  
pp. 772-777 ◽  
Author(s):  
Sybille Albrecht ◽  
Matthias Kotzsch ◽  
Gabriele Siegert ◽  
Thomas Luther ◽  
Heinz Großmann ◽  
...  

SummaryThe plasma tissue factor (TF) concentration was correlated to factor VII concentration (FVIIag) and factor VII activity (FVIIc) in 498 healthy volunteers ranging in age from 17 to 64 years. Immunoassays using monoclonal antibodies (mAbs) were developed for the determination of TF and FVIIag in plasma. The mAbs and the test systems were characterized. The mean value of the TF concentration was 172 ± 135 pg/ml. TF showed no age- and gender-related differences. For the total population, FVIIc, determined by a clotting test, was 110 ± 15% and the factor VIlag was 0.77 ± 0.19 μg/ml. FVII activity was significantly increased with age, whereas the concentration demonstrated no correlation to age in this population. FVII concentration is highly correlated with the activity as measured by clotting assay using rabbit thromboplastin. The ratio between FVIIc and FVIIag was not age-dependent, but demonstrated a significant difference between men and women. Between TF and FVII we could not detect a correlation.


1966 ◽  
Vol 16 (01/02) ◽  
pp. 038-050 ◽  
Author(s):  
Ulla Hedner ◽  
Inga Marie Nilsson ◽  
B Robertson

SummaryThe plasminogen content was determined by a casein method in plasma and serum from 20 normal volunteers. The mean plasminogen content was found to be 10.1 ACU (the arbitrary caseinolytic unit defined in such a way that using a 3% casein solution and a digestion time of 20 min. at 37°C, 10 ACU gave an extinction of 0.300). No difference between serum and plasma regarding the plasminogen content was found.Plasminogen was determined in drained and drained plus washed clots prepared from 2 ml plasma. The highest values found in the drained clots were 0.9 ACU/clot and 0.2 ACU/clot in the drained plus washed clots.Plasminogen was also determined in drained and drained plus washed clots prepared from plasma with added purified plasminogen. The plasminogen was recovered in the washing fluid. According to these tests, then, purified added plasminogen is washed out of the clots.The plasminogen content of 20 thrombi obtained post mortem was also determined. The mean value was found to be 0.7 ACU/cm thrombus. Judging from our results, the “intrinsic clot lysis theory” is not the main mechanism of clot dissolution.


1973 ◽  
Vol 72 (4) ◽  
pp. 714-726 ◽  
Author(s):  
A. Burger ◽  
B. Miller ◽  
C. Sakoloff ◽  
M. B. Vallotton

ABSTRACT An improved method for the determination of serum triiodothyronine (T3) has been developed. After addition of a tracer amount of the hormone, T3 was extracted from 1 ml serum under conditions of pH and ionic strength which favoured T3 extraction (89%) over thyroxine (T4) extraction (58%). Chromatography of the extracted material on Sephadex LH-20 separated T3 completely from residual T4. The T3 eluate was dried, then re-dissolved in 0.5 ml NaOH 0.04 n. To 0.2 ml duplicate aliquots, a standard amount of TBG was added for the competitive protein analysis. After one hour incubation at 4°C, separation of bound from free T3 was achieved on small Sephadex G-25 columns. Overall recovery was 67 ± 10.8% and correction for the loss was made. The solvent blank was 37 ± 27 (sd) ng/100 ml. Accuracy of measurement of known quantities of T3 added to serum was 98.4%. The coefficient of variation within the assay was 6.2% and between the assays it was 11.4%. The limit of detection (0.1 ng) corresponded to a concentration of 25 ng/100 ml. T4 added to serum did not interfere with T3 determination until high non-physiological values were reached. The mean ± sd serum T3 in 54 euthyroid subjects was 153 ± 58 ng/100 ml and in 24 hyperthyroid patients it was 428 ±186 ng/100 ml; 4 out of the 24 hyperthyroid values were within 2 sd of the mean euthyroid group. All the values found in the euthyroid group were well above the limit of detection of the method.


2002 ◽  
Vol 727 ◽  
Author(s):  
S. Ichikawa ◽  
T. Akita ◽  
M. Okumura ◽  
M. Haruta ◽  
K. Tanaka

AbstractThe catalytic properties of nanostructured gold catalyst are known to depend on the size of the gold particles and to be activated when the size decreases to a few nanometers. We investigated the size dependence of the three-dimensional nanostructure on the mean inner potential of gold catalysts supported on titanium oxide using electron holography and high-resolution electron microscopy (HREM). The contact angle of the gold particles on the titanium oxide tended to be over 90° for gold particles with a size of over 5 nm, and below 90° for a size of below 2 nm. This decreasing change in the contact angle (morphology) acts to increase the perimeter and hence the area of the interface between the gold and titanium oxide support, which is considered to be an active site for CO oxidation. The mean inner potential of the gold particles also changed as their size decreased. The value of the inner potential of gold, which is approximately 25 V in bulk state, rose to over 40 V when the size of the gold particles was less than 2 nm. This phenomenon indicates the existence of a charge transfer at the interface between gold and titanium oxide. The 3-D structure change and the inner potential change should be attributed to the specific electronic structure at the interface, owing to both the “nano size effect” and the “hetero-interface effect.”


Sign in / Sign up

Export Citation Format

Share Document