Performance analysis of SiRe next-generation sequencing panel in diagnostic setting: focus on NSCLC routine samples

2018 ◽  
Vol 72 (1) ◽  
pp. 38-45 ◽  
Author(s):  
Francesco Pepe ◽  
Caterina De Luca ◽  
Riccardo Smeraglio ◽  
Pasquale Pisapia ◽  
Roberta Sgariglia ◽  
...  

AimsFollowing the development for liquid biopsies of the SiRe next-generation sequencing (NGS) panel that covers 568 clinical relevant mutations in EGFR, KRAS, NRAS, BRAF, cKIT and PDGFRa genes, in this current study, we apply this small NGS panel on tissue samples of lung cancer.MethodsA total of 322 specimens were prospectively tested. Technical parameters were analysed on both cytological and histological samples. In a subset of 75 samples, the EGFR SiRe results were compared with those generated by the European Community (CE)–IVD EGFR assay on Idylla platform. Clinical outcomes of 11 patients treated, on the basis of SiRe results, were also evaluated.ResultsOnly 28 (8.7%) specimens failed to produce a library; out of the 294 remaining samples, a total of 168 somatic mutations were found. In nearly all instances (74/75–99%), the EGFR SiRe results were confirmed by Idylla. In general, SiRe analytical parameters were excellent. However, histological and cytological specimens differed in relation to average reads for sample, mean number of mapped reads, median read length and average reads for amplicon. Treatment outcome evaluation in 11 patients showed a partial response in 82 % (9/11) patients with a median progression-free survival of 340 days.ConclusionsThe small gene panel SiRe is a clinically relevant tool useful to widespread the adoption of NGS in predictive molecular pathology laboratories.

2020 ◽  
Vol 15 ◽  
Author(s):  
Zheng Jiang ◽  
Hui Liu ◽  
Siwen Zhang ◽  
Jia Liu ◽  
Weitao Wang ◽  
...  

Background: Microsatellite instability (MSI) is a prognostic biomarker used to guide medication selection in multiple cancers, such as colorectal cancer. Traditional PCR with capillary electrophoresis and next-generation sequencing using paired tumor tissue and leukocyte samples are the main approaches for MSI detection due to their high sensitivity and specificity. Currently, patient tissue samples are obtained through puncture or surgery, which causes injury and risk of concurrent disease, further illustrating the need for MSI detection by liquid biopsy. Methods: We propose an analytic method using paired plasma/leukocyte samples and MSI detection using next-generation sequencing technology. Based on the theoretical progress of oncogenesis, we hypothesized that the microsatellite site length in plasma equals the combination of the distribution of tumor tissue and leukocytes. Thus, we defined a window-judgement method to identify whether biomarkers were stable. Results: Compared to traditional PCR as the standard, we evaluated three methods in 20 samples (MSI-H:3/MSS:17): peak shifting method using tissue vs. leukocytes, peak shifting method using plasma vs. leukocytes, and our method using plasma vs. leukocytes. Compared to traditional PCR, we observed a sensitivity of 100%, 0%, and 100%, and a specificity of 100.00%, 94.12%, and 88.24%, respectively. Conclusion: Our method has the advantage of possibly detecting MSI in a liquid biopsy and provides a novel direction for future studies to increase the specificity of the method.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Imteyaz Ahmad Khan ◽  
Safoora Rashid ◽  
Nidhi Singh ◽  
Sumaira Rashid ◽  
Vishwajeet Singh ◽  
...  

AbstractEarly-stage diagnosis of pancreatic ductal adenocarcinoma (PDAC) is difficult due to non-specific symptoms. Circulating miRNAs in body fluids have been emerging as potential non-invasive biomarkers for diagnosis of many cancers. Thus, this study aimed to assess a panel of miRNAs for their ability to differentiate PDAC from chronic pancreatitis (CP), a benign inflammatory condition of the pancreas. Next-generation sequencing was performed to identify miRNAs present in 60 FFPE tissue samples (27 PDAC, 23 CP and 10 normal pancreatic tissues). Four up-regulated miRNAs (miR-215-5p, miR-122-5p, miR-192-5p, and miR-181a-2-3p) and four down-regulated miRNAs (miR-30b-5p, miR-216b-5p, miR-320b, and miR-214-5p) in PDAC compared to CP were selected based on next-generation sequencing results. The levels of these 8 differentially expressed miRNAs were measured by qRT-PCR in 125 serum samples (50 PDAC, 50 CP, and 25 healthy controls (HC)). The results showed significant upregulation of miR-215-5p, miR-122-5p, and miR-192-5p in PDAC serum samples. In contrast, levels of miR-30b-5p and miR-320b were significantly lower in PDAC as compared to CP and HC. ROC analysis showed that these 5 miRNAs can distinguish PDAC from both CP and HC. Hence, this panel can serve as a non-invasive biomarker for the early detection of PDAC.


2018 ◽  
Vol 3 (2) ◽  
pp. 178-184 ◽  
Author(s):  
M Rabie Al-Turkmani ◽  
Kelley N Godwin ◽  
Jason D Peterson ◽  
Gregory J Tsongalis

AbstractBackgroundMolecular tests have been increasingly used in the management of various cancers as more targeted therapies are becoming available as treatment options. The Idylla™ system is a fully integrated, cartridge-based platform that provides automated sample processing (deparaffinization, tissue digestion, and DNA extraction) and real-time PCR-based mutation detection with all reagents included in a single-use cartridge. This retrospective study aimed at evaluating both the Idylla KRAS and NRAS-BRAF-EGFR492 Mutation Assay cartridges (research use only) against next-generation sequencing (NGS) by using colorectal cancer (CRC) tissue samples.MethodsForty-four archived formalin-fixed paraffin-embedded (FFPE) CRC tissue samples previously analyzed by targeted NGS were tested on the Idylla system. Among these samples, 17 had a mutation in KRAS proto-oncogene, GTPase (KRAS), 5 in NRAS proto-oncogene, GTPase (NRAS), and 12 in B-Raf proto-oncogene, serine/threonine kinase (BRAF) as determined using the Ion AmpliSeq 50-gene Cancer Hotspot Panel v2. The remaining 10 samples were wild-type for KRAS, NRAS, and BRAF. Two 10-μm FFPE tissue sections were used for each Idylla run, 1 for the KRAS cartridge, and 1 for the NRAS-BRAF-EGFR492 cartridge. All cases met the Idylla minimum tumor content requirement for KRAS, NRAS, and BRAF (≥10%). Assay reproducibility was evaluated by testing commercial controls derived from human cell lines, which had an allelic frequency of 50% and were run in triplicate.ResultsThe Idylla system successfully detected all mutations previously identified by NGS in KRAS (G12C, G12D, G12V, G13D, Q61K, Q61R, A146T), NRAS (G12V, G13R, Q61H), and BRAF (V600E). Compared with NGS, Idylla had a sensitivity of 100%. Analysis of the mutated commercial controls demonstrated agreement with the expected result for all samples and 100% reproducibility. The Idylla system produced results quickly with a turnaround time of approximately 2 h.ConclusionThe Idylla system offers reliable and sensitive testing of clinically actionable mutations in KRAS, NRAS, and BRAF directly from FFPE tissue sections.


2021 ◽  
Vol 9 (8) ◽  
pp. 1716
Author(s):  
Dániel Cadar ◽  
Kurt A. Jellinger ◽  
Peter Riederer ◽  
Sabrina Strobel ◽  
Camelia-Maria Monoranu ◽  
...  

Postencephalitic parkinsonism (PEP) is a disease of unknown etiology and pathophysiology following encephalitis lethargica (EL), an acute-onset polioencephalitis of cryptic cause in the 1920s. PEP is a tauopathy with multisystem neuronal loss and gliosis, clinically characterized by bradykinesia, rigidity, rest tremor, and oculogyric crises. Though a viral cause of EL is likely, past polymerase chain reaction-based investigations in the etiology of both PEP and EL were negative. PEP might be caused directly by an unknown viral pathogen or the consequence of a post-infectious immunopathology. The development of metagenomic next-generation sequencing in conjunction with bioinformatic techniques has generated a broad-range tool for the detection of unknown pathogens in the recent past. Retrospective identification and characterization of pathogens responsible for past infectious diseases can be successfully performed with formalin-fixed paraffin-embedded (FFPE) tissue samples. In this study, we analyzed 24 FFPE brain samples from six patients with PEP by unbiased metagenomic next-generation sequencing. Our results show that no evidence for the presence of a specific or putative (novel) viral pathogen was found, suggesting a likely post-infectious immune-mediated etiology of PEP.


2020 ◽  
Vol 58 (2) ◽  
pp. 306-313 ◽  
Author(s):  
Mariano Provencio ◽  
Clara Pérez-Barrios ◽  
Miguel Barquin ◽  
Virginia Calvo ◽  
Fabio Franco ◽  
...  

AbstractBackgroundNon-small cell lung cancer (NSCLC) patients benefit from targeted therapies both in first- and second-line treatment. Nevertheless, molecular profiling of lung cancer tumors after first disease progression is seldom performed. The analysis of circulating tumor DNA (ctDNA) enables not only non-invasive biomarker testing but also monitoring tumor response to treatment. Digital PCR (dPCR), although a robust approach, only enables the analysis of a limited number of mutations. Next-generation sequencing (NGS), on the other hand, enables the analysis of significantly greater numbers of mutations.MethodsA total of 54 circulating free DNA (cfDNA) samples from 52 NSCLC patients and two healthy donors were analyzed by NGS using the Oncomine™ Lung cfDNA Assay kit and dPCR.ResultsLin’s concordance correlation coefficient and Pearson’s correlation coefficient between mutant allele frequencies (MAFs) assessed by NGS and dPCR revealed a positive and linear relationship between the two data sets (ρc = 0.986; 95% confidence interval [CI] = 0.975–0.991; r = 0.987; p < 0.0001, respectively), indicating an excellent concordance between both measurements. Similarly, the agreement between NGS and dPCR for the detection of the resistance mutation p.T790M was almost perfect (K = 0.81; 95% CI = 0.62–0.99), with an excellent correlation in terms of MAFs (ρc = 0.991; 95% CI = 0.981–0.992 and Pearson’s r = 0.998; p < 0.0001). Importantly, cfDNA sequencing was successful using as low as 10 ng cfDNA input.ConclusionsMAFs assessed by NGS were highly correlated with MAFs assessed by dPCR, demonstrating that NGS is a robust technique for ctDNA quantification using clinical samples, thereby allowing for dynamic genomic surveillance in the era of precision medicine.


2020 ◽  
Vol 27 (3) ◽  
pp. 107327482093480
Author(s):  
Ting-Miao Wu ◽  
Ji-Bin Liu ◽  
Yu Liu ◽  
Yi Shi ◽  
Wen Li ◽  
...  

Traditional methods of cancer treatment are usually based on the morphological and histological diagnosis of tumors, and they are not optimized according to the specific situation. Precision medicine adjusts the existing treatment regimen based on the patient’s genomic information to make it most suitable for patients. Detection of genetic mutations in tumors is the basis of precise cancer medicine. Through the analysis of genetic mutations in patients with cancer, we can tailor the treatment plan for each patient with cancer to maximize the curative effect, minimize damage to healthy tissues, and optimize resources. In recent years, next-generation sequencing technology has developed rapidly and has become the core technology of precise targeted therapy and immunotherapy for cancer. From early cancer screening to treatment guidance for patients with advanced cancer, liquid biopsy is increasingly used in cancer management. This is as a result of the development of better noninvasive, repeatable, sensitive, and accurate tools used in early screening, diagnosis, evaluation, and monitoring of patients. Cell-free DNA, which is a new noninvasive molecular pathological detection method, often carries tumor-specific gene changes. It plays an important role in optimizing treatment and evaluating the efficacy of different treatment options in clinical trials, and it has broad clinical applications.


2019 ◽  
Vol 14 (10) ◽  
pp. S840-S841
Author(s):  
M. Garcia Pardo ◽  
I. Martinez Delfrade ◽  
I. Aparicio Salcedo ◽  
M. Arregui Valles ◽  
M. Alva Bianchi ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document