WP1-15 Computer-assisted versus manual planning for stereotactic brain biopsy: retrospective comparative pilot study

2019 ◽  
Vol 90 (3) ◽  
pp. e5.3-e4 ◽  
Author(s):  
HJ Marcus ◽  
VN Vakharia ◽  
R Sparks ◽  
R Rodionov ◽  
N Kitchen ◽  
...  

ObjectivesStereotactic brain biopsy is among the most common neurosurgical procedures. Planning a safe surgical trajectory requires careful attention to a number of features including:traversing the skull perpendicularly;avoiding critical neurovascular structures; andminimising trajectory length.The aim of this study was to develop a platform, SurgiNav, for automated trajectory planning in stereotactic brain biopsy.MethodsA prospectively maintained database was searched between February and August 2017 to identify all adult patients that underwent stereotactic brain biopsy in whom post-operative imaging was available. In each case, the standard pre-operative T1-weighted gadolinium-enhanced MRI was used to generate models of the cortex and vasculature. A surgical trajectory was then generated using automated computer-assisted planning (CAP) and metrics compared to the trajectory of the implemented manual plan (MP) using the paired T-test.Results15 consecutive patients were identified; who had a diagnostic biopsy and there were no immediate complications. Feasible trajectories were generated using CAP in 12 patients, and in these the mean trajectory length using CAP was comparable to MP (31.7 mm vs. 37.1 mm; p=0.3), and mean angle was similarly perpendicular from orthogonal (9.3° vs. 15.3° p=0.1), but the risk-metric was significantly lower (0.16 vs. 0.48; p=0.03).ConclusionsComputer-assisted planning for stereotactic brain biopsy appears feasible in most cases and may be safer in selected cases.

Author(s):  
PJ Gariscsak ◽  
C Gui ◽  
JC Lau ◽  
JF Megyesi

Background: Historically, frame-based stereotactic brain biopsy (SBB) has played an important role in the diagnosis of intracranial lesions. We performed a single centre analysis of the outcomes and efficacy of SBB at the London Health Sciences Centre (LHSC). Methods: We performed a retrospective chart review of frame-based SBB from 2006 to 2017 at the LHSC. Intra-operative and final pathology reports were analyzed for biopsy diagnosis and the diagnosis was compared with pre-operative neuroimaging reports for correlation. SBB-associated morbidity and mortality were investigated using chart review and post-operative neuroimaging. Results: 173 consecutive patients were identified. The overall morbidity rate was 8.7% (15 cases) and mortality rate was 0.6% (1 case). Final biopsy diagnostic accuracy was 96%, intra-operative diagnostic accuracy was 94% and pre-operative imaging diagnostic accuracy was 65%. Elevated partial thromboplastin time and the presence of hemorrhage on post-operative CT were associated with neurological morbidity and mortality. The need to obtain three or greater samples the time of biopsy was associated with non-diagnostic biopsy. Conclusions: At the LHSC, SBB is a relatively safe and effective surgical procedure with high diagnostic yield and relatively low risk of complications. Intra-operative pathology has a high efficacy in determining diagnosis when compared to final pathology.


2016 ◽  
Vol 124 (4) ◽  
pp. 1039-1046 ◽  
Author(s):  
Ahmed Mohyeldin ◽  
Russell R. Lonser ◽  
J. Bradley Elder

OBJECT The object of this study was to assess the feasibility, accuracy, and safety of real-time MRI-compatible frameless stereotactic brain biopsy. METHODS Clinical, imaging, and histological data in consecutive patients who underwent stereotactic brain biopsy using a frameless real-time MRI system were analyzed. RESULTS Five consecutive patients (4 males, 1 female) were included in this study. The mean age at biopsy was 45.8 years (range 29–60 years). Real-time MRI permitted concurrent display of the biopsy cannula trajectory and tip during placement at the target. The mean target depth of biopsied lesions was 71.3 mm (range 60.4–80.4 mm). Targeting accuracy analysis revealed a mean radial error of 1.3 ± 1.1 mm (mean ± standard deviation), mean depth error of 0.7 ± 0.3 mm, and a mean absolute tip error of 1.5 ± 1.1 mm. There was no correlation between target depth and absolute tip error (Pearson product-moment correlation coefficient, r = 0.22). All biopsy cannulae were placed at the target with a single penetration and resulted in a diagnostic specimen in all cases. Histopathological evaluation of biopsy samples revealed dysembryoplastic neuroepithelial tumor (1 case), breast carcinoma (1 case), and glioblastoma multiforme (3 cases). CONCLUSIONS The ability to place a biopsy cannula under real-time imaging guidance permits on-the-fly alterations in the cannula trajectory and/or tip placement. Real-time imaging during MRI-guided brain biopsy provides precise safe targeting of brain lesions.


1965 ◽  
Vol 49 (1) ◽  
pp. 1-16 ◽  
Author(s):  
M. Apostolakis

ABSTRACT A method for the extraction of prolactin from human pituitary glands is described. It is based on acetone drying, distilled water extraction, acetone and isoelectric precipitation. Two main products are obtained: Fraction R8 with a mean prolactin activity of 12.2 IU/mg and fraction U8 with a mean prolactin activity of 8.6 IU/mg. The former fraction does not contain any significant gonadotrophin activity and the latter contains on an average 50 HMG U/mg. In both cases contamination with ACTH and MSH is minimal. The growth hormone activity of both these fractions is low. It is postulated that in man too, prolactin and growth hormone are two distinct hormones. A total of 1250 human pituitary glands have been processed by this method. The mean prolactin content per pituitary gland has been found to be 73 IU.


1974 ◽  
Vol 75 (1) ◽  
pp. 50-63 ◽  
Author(s):  
Kristian F. Hanssen

ABSTRACT Twenty newly diagnosed, but as yet untreated patients of both sexes with classical juvenile diabetes were investigated by determining the mean plasma immunoreactive growth hormone (IRHGH) and urinary IRHGH for a 24 hour period before and during initial insulin treatment. The plasma IRHGH was significantly higher (0.05 > P > 0.01) before than during initial insulin treatment. During initial insulin treatment, the mean plasma IRHGH was significantly higher (0.01 > P > 0.001) than in a control group. The urinary IRHGH was significantly higher (0.01 > P > 0.001) before than during insulin treatment. The increased urinary IRHGH observed before insulin treatment is thought to be partly due to a defective renal tubular reabsorption of growth hormone. No significant correlation was found between the mean blood sugar and plasma or urinary IRHGH either before or during insulin treatment.


1960 ◽  
Vol XXXIII (II) ◽  
pp. 230-250 ◽  
Author(s):  
Eileen E. Hill

ABSTRACT A method for the fractionation of the urinary 17-ketogenic steroids with no oxygen grouping at C11 and those oxygenated at C11, is applied to the clinical problems of congenital adrenal hyperplasia. In normal children the mean ratio of the non-oxygenated to oxygenated steroids is 0.24. In childrern with congenital adrenal hyperplasia the ratio is 2.3. The reason for this difference in ratio is discussed. The changes in ratio found under stimulation of the adrenal gland with exogenous or endogenous corticotrophin and the suppression with cortisone therapy are studied. This test can be applied to isolated samples of urine, a major advantage in paediatric practice, and can be carried out in routine laboratories. It is found to be reliable in the diagnosis and sensitive in the control of congenital adrenal hyperplasia.


Author(s):  
A. Kinaci ◽  
S. van Thoor ◽  
S. Redegeld ◽  
M. Tooren ◽  
T. P. C. van Doormaal

AbstractCerebrospinal fluid leakage is a frequent complication after cranial and spinal surgery. To prevent this complication and seal the dura watertight, we developed Liqoseal, a dural sealant patch comprising a watertight polyesterurethane layer and an adhesive layer consisting of poly(DL-lactide-co-ε-caprolactone) copolymer and multiarmed N-hydroxylsuccinimide functionalized polyethylene glycol. We compared acute burst pressure and resistance to physiological conditions for 72 h of Liqoseal, Adherus, Duraseal, Tachosil, and Tisseel using computer-assisted models and fresh porcine dura. The mean acute burst pressure of Liqoseal in the cranial model (145 ± 39 mmHg) was higher than that of Adherus (87 ± 47 mmHg), Duraseal (51 ± 42 mmHg) and Tachosil (71 ± 16 mmHg). Under physiological conditions, cranial model resistance test results showed that 2 of 3 Liqoseal sealants maintained dural attachment during 72 hours as opposed to 3 of 3 for Adherus and Duraseal and 0 of 3 for Tachosil. The mean burst pressure of Liqoseal in the spinal model (233 ± 81 mmHg) was higher than that of Tachosil (123 ± 63 mmHg) and Tisseel (23 ± 16 mmHg). Under physiological conditions, spinal model resistance test results showed that 2 of 3 Liqoseal sealants maintained dural attachment for 72 hours as opposed to 3 of 3 for Adherus and 0 of 3 for Duraseal and Tachosil. This novel study showed that Liqoseal is capable of achieving a strong watertight seal over a dural defect in ex vivo models.


2020 ◽  
Vol 5 (2) ◽  
pp. 1405-1412
Author(s):  
Minxin Ye ◽  
Weibing Li ◽  
Danny Tat Ming Chan ◽  
Philip Wai Yan Chiu ◽  
Zheng Li

2012 ◽  
Vol 90 (1) ◽  
pp. 63-65 ◽  
Author(s):  
Mikhail Chernov ◽  
Yoshihiro Muragaki ◽  
Takaomi Taira ◽  
Hiroshi Iseki

2011 ◽  
Vol 17 (12) ◽  
pp. 1531-1538 ◽  
Author(s):  
Rania GA Elenein ◽  
Leroy R Sharer ◽  
Stuart D Cook ◽  
Andrew R Pachner ◽  
Jennifer Michaels ◽  
...  

Marburg’s variant of multiple sclerosis is a rapidly progressive and malignant form of multiple sclerosis (MS) that usually leads to severe disability or death within weeks to months without remission. Few cases have been described in the literature since the original description by Marburg. The classic pathological findings usually include highly destructive zones of extensive demyelination, necrosis with dense cellular infiltrate, and giant reactive astrocytes. We report a case of a 31-year-old woman with Marburg’s variant of MS who, over a period of eight months, became totally disabled, blind, and quadriplegic, with vocal cord paralysis, requiring a tracheostomy. The patient underwent diagnostic stereotactic brain biopsy. Clinical findings, magnetic resonance imaging (MRI), serologic and cerebrospinal fluid (CSF) findings, and neuropathology are discussed. MRI showed extensive white matter involvement in the brain and spinal cord that continuously progressed over time. A diagnostic stereotactic brain biopsy revealed extensive active demyelination with unexpected finding of active vasculitis and fibrinoid necrosis with a vascular inflammatory cell infiltrate, including polymorphonuclear neutrophils and rare eosinophils. Serologic work-up for vasculitis and neuromyelitis optica was unremarkable and the CSF showed only one oligoclonal band (OCB) not present in serum. This is the second case of Marburg’s variant of MS that demonstrated both demyelination and vasculitis. In our case these features were demonstrated simultaneously, even though the demyelination was the predominant pathological finding. Since vasculitis is not a feature of classic MS, these findings pose the question as to whether Marburg’s variant of MS is a true variant or different entity altogether.


2006 ◽  
Vol 104 (2) ◽  
pp. 233-237 ◽  
Author(s):  
Graeme F. Woodworth ◽  
Matthew J. McGirt ◽  
Amer Samdani ◽  
Ira Garonzik ◽  
Alessandro Olivi ◽  
...  

Object The gold standard for stereotactic brain biopsy target localization has been frame-based stereotaxy. Recently, frameless stereotactic techniques have become increasingly utilized. Few authors have evaluated this procedure, analyzed preoperative predictors of diagnostic yield, or explored the differences in diagnostic yield and morbidity rate between the frameless and frame-based techniques. Methods A consecutive series of 110 frameless and 160 frame-based image-guided stereotactic biopsy procedures was reviewed. Associated variables for both techniques were reviewed and compared. All stereotactic biopsy procedures were included in a risk factor analysis of nondiagnostic biopsy sampling. Frameless stereotaxy led to a diagnostic yield of 89%, with a total permanent morbidity rate of 6% and a mortality rate of 1%. Larger lesions were fivefold more likely to yield diagnostic tissues. Deep-seated lesions were 2.7-fold less likely to yield diagnostic tissues compared with cortical lesions. Frameless compared with frame-based stereotactic biopsy procedures showed no significant differences in diagnostic yield or transient or permanent morbidity. For cortical lesions, more than one needle trajectory was required more frequently to obtain diagnostic tissues with frame-based as opposed to frameless stereotaxy, although this factor was not associated with morbidity. Conclusions With regard to diagnostic yield and complication rate, the frameless stereotactic biopsy procedure was found to be comparable to or better than the frame-based method. Smaller and deep-seated lesions together were risk factors for a nondiagnostic tissue yield. Frameless stereotaxy may represent a more efficient means of obtaining biopsy specimens of cortical lesions but is otherwise similar to the frame-based technique.


Sign in / Sign up

Export Citation Format

Share Document