SIZE REQUIREMENTS OF COMPACT SANDWICH SPECIMEN FOR TESTING OF BONE

2007 ◽  
Vol 07 (04) ◽  
pp. 419-431
Author(s):  
SATYA PRASAD PARUCHURU ◽  
ANUJ JAIN ◽  
XIAODU WANG

It is well understood that bone quality deteriorates due to aging, disease, etc., and may be affected by factors at different length scales due to its hierarchical microstructure. Fracture toughness is one of the properties that assess bone quality. The compact sandwich (CS) specimen gives a better choice of bone sample size, and therefore suits a wide variety of fracture toughness testing needs and constraints. Reliable and statistically valid overall CS specimen size requirements are established in this paper; these serve as guidelines for choosing the CS specimen size. Finite element analysis (FEA) is used for simulating fracture toughness tests. Experimental fracture toughness tests are carried out to verify the FEA results. The experimental results are verified qualitatively by performing scanning electron microscopy (SEM) on the fractured specimen surfaces.

Nanomaterials ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 446
Author(s):  
Ioannis Spanos ◽  
Zacharias Vangelatos ◽  
Costas Grigoropoulos ◽  
Maria Farsari

The need for control of the elastic properties of architected materials has been accentuated due to the advances in modelling and characterization. Among the plethora of unconventional mechanical responses, controlled anisotropy and auxeticity have been promulgated as a new avenue in bioengineering applications. This paper aims to delineate the mechanical performance of characteristic auxetic and anisotropic designs fabricated by multiphoton lithography. Through finite element analysis the distinct responses of representative topologies are conveyed. In addition, nanoindentation experiments observed in-situ through scanning electron microscopy enable the validation of the modeling and the observation of the anisotropic or auxetic phenomena. Our results herald how these categories of architected materials can be investigated at the microscale.


2011 ◽  
Vol 691 ◽  
pp. 32-36
Author(s):  
José G. Miranda-Hernández ◽  
Elizabeth Refugio-García ◽  
Eduardo Térres-Rojas ◽  
Enrique Rocha-Rangel

The effect of different titanium additions (0.5, 1, 2, 3 and 10 vol. %), milling intensity (4 and 8 h) and sintered temperature (1500 and 1600 °C) on microstructure and fracture toughness of Al2O3-based composites was analyzed in this study. After high energy milling of a titanium and Al2O3mixtures, powder mixture presents fine distribution and good homogenization between ceramic and metal. After milling powders during 8 h they were obtained very fine particles with 200 nm average sizes. Microstructures of the sintered bodies were analyzed with a scanning electron microscopy, where it was observed that the microstructure presents the formation of a small and fine metallic net inside the ceramic matrix. From fracture toughness measurements realized by the fracture indentation method, it had that when titanium content in the composite increases, fracture toughness is enhanced until 83% with respect to the fracture toughness of pure Al2O3. This behavior is due to the formation of metallic bridges by titanium in the Al2O3matrix.


2012 ◽  
Vol 512-515 ◽  
pp. 706-709 ◽  
Author(s):  
Chang Ling Zhou ◽  
Yan Yan Wang ◽  
Zhi Qiang Cheng ◽  
Chong Hai Wang ◽  
Rui Xiang Liu

ZrB2-20%volSiC ceramic composites with different volume of BN short fiber were fabricated by the hot-pressing sintering under 2000°C. The content of BN short fiber changed from 0 to 15vol%. The density, flexural strength, fracture toughness and thermal expansions coefficient were studied. The microstructures of the samples were observed by scanning electron microscopy. The results show that the introducing of BN short fiber into the ZrB2-20%volSiC lead to a serious of change to the mechanical properties of the ceramic. When the content of the BN short fiber is 10vol%, the flexural strength and fracture toughness reach 422.1MPa and 6.15 MPa•m 1/2 respectively. And the mechanism of the increasing toughness was studied.


2015 ◽  
Vol 27 (02) ◽  
pp. 1550013 ◽  
Author(s):  
M. M. Youssef ◽  
D. E. T. Shepherd ◽  
O. G. Titley

A failed compass hinge external fixator for fingers has been analyzed. The device consists of polymer parts manufactured from polyetherimide. Finite element analysis (FEA) was used to investigate the principal stresses in the device under different loading conditions. Scanning electron microscopy (SEM) was used to investigate the fracture surfaces. The FEA showed that the maximum principal stress was greater than the fatigue strength of polyetherimide. The SEM fractographs confirm that failure was by brittle fatigue.


2020 ◽  
Author(s):  
ahmed Al Ghaithi ◽  
Sultan Al Mastari ◽  
John Husband ◽  
Mohammed al kindi ◽  
Atika Al Bimani

AbstractPurposeOsteomyelitis is an infectious bone process leading to bone necrosis and destruction. Published reports on pathogen biofilm thus far have focused on indirect bone resorption mediated by host cells and factors secondary to immune system activation. However, direct bone resorption due to biofilm pathogen has not been adequately studied yet. This study aims to investigate the effect of biofilm pathogen in ex-vivo human bones in the absence of the host immune response using Raman spectroscopy and Scanning electron microscopy.MethodsBone samples collected from patients who underwent knee replacement surgeries were inoculated with Staphylococcus aureus bacteria. Bacterial direct effects on the bone quality were then examined, at various time intervals, using Raman spectroscopy and scanning electron microscopy.ResultsRaman spectroscopy and scanning electron demonstrated the destruction of bone structure and drop in bone quality.ConclusionThis experiment shows the direct effect of bacteria on bone during osteomyelitis in addition to the recognised destruction caused by the host immune system.


2007 ◽  
Vol 336-338 ◽  
pp. 1424-1425
Author(s):  
Sui Lin Shi ◽  
Ling Zhen Zhang

In this study, Al2O3-TiC composite was prepared at 1600°C for 1 h by hot-pressing using the Al2O3-TiC composite powder synthesized from self-propagating high-temperature synthesis (SHS) process. Mechanical properties of the composite were investigated, such as bulk density, Vickers hardness, fracture toughness and bending strength. The microstructure of the composite was also investigated by scanning electron microscopy (SEM).


2013 ◽  
Vol 2013 ◽  
pp. 1-15 ◽  
Author(s):  
Nilormi Biswas ◽  
Arjun Dey ◽  
Saugata Kundu ◽  
Himel Chakraborty ◽  
Anoop K. Mukhopadhyay

For adult Indian premolar teeth, we report for the first time ever the simultaneous evaluations of nanohardness, Young's modulus, and fracture toughness of the enamel nanocomposite. The nanohardness and Young's moduli were evaluated from near the beginning of the middle enamel region to within ~10 μm of the dentino-enamel junction (DEJ) and in the dentin region using the nanoindentation technique. The fracture toughness from near the middle of the enamel region to near the DEJ zone was measured using the microindentation technique. The deformation was studied using scanning electron microscopy (SEM) and field emission scanning electron microscopy (FESEM). The relative differences in the extents of biomineralization in the enamel and dentin regions were studied by the energy dispersive X-ray (EDS) technique. The variations of the toughness of the enamel as a function of the toughness of the protein matrix phase have been analyzed which showed that the predicted value of the toughness of the protein present in the nanocomposite was comparable to that of other bioproteins reported in the literature. Further, the work of fracture estimated from the measured value of toughness of the enamel nanocomposite agreed well with the experimental data reported in the literature.


Sign in / Sign up

Export Citation Format

Share Document