ENGINEERING ANALYSIS OF A FAILED COMPASS PROXIMAL INTERPHALANGEAL (PIP) JOINT HINGE

2015 ◽  
Vol 27 (02) ◽  
pp. 1550013 ◽  
Author(s):  
M. M. Youssef ◽  
D. E. T. Shepherd ◽  
O. G. Titley

A failed compass hinge external fixator for fingers has been analyzed. The device consists of polymer parts manufactured from polyetherimide. Finite element analysis (FEA) was used to investigate the principal stresses in the device under different loading conditions. Scanning electron microscopy (SEM) was used to investigate the fracture surfaces. The FEA showed that the maximum principal stress was greater than the fatigue strength of polyetherimide. The SEM fractographs confirm that failure was by brittle fatigue.

2021 ◽  
Vol 23 (8) ◽  
pp. 2170031
Author(s):  
Somayeh Moradi ◽  
Nathanael Jöhrmann ◽  
Dmitriy D. Karnaushenko ◽  
Uwe Zschenderlein ◽  
Daniil Karnaushenko ◽  
...  

2021 ◽  
Author(s):  
Ιάκωβος Ξενικάκης

Η χρήση μικροβελόνων είναι μία μέθοδος η οποία επιτρέπει τη διάτρηση της κερατίνης στιβάδας και το σχηματισμό πόρων μέσω των οποίων επιτυγχάνεται διαδερμική χορήγηση φαρμάκων. Με αυτή τη μέθοδο μπορούν να χορηγηθούν φάρμακα τα οποία σε άθικτο δέρμα έχουν μηδαμινή απορρόφηση. Τέτοιου είδους φάρμακα είναι και τα μακρομόρια, μεταξύ των οποίων και οι πρωτεΐνες. Η επίτευξη διαδερμικής χορήγησης μακρομορίων θα βελτίωνε την καθημερινότητα και τη συμμόρφωση στη θεραπεία ασθενών που υποχρεώνονται σε τακτική παρεντερική χορήγηση της θεραπείας τους (π.χ. διαβητικοί). Παράλληλα, η χρήση της Προσθετικής Κατασκευής επιτρέπει την κατασκευή των μικροβελόνων με γρήγορο, εύκολο, ευέλικτο και οικονομικό τρόπο χάρη στους ακόλουθους λόγους: α) τα σχέδια των μικροβελόνων σώζονται ως αρχεία .stl και μπορούν να τροποποιηθούν όποτε κριθεί απαραίτητο, β) η διαδικασία κατασκευής συνοψίζεται σε ένα στάδιο στο οποίο στιβάδες του υλικού εκτύπωσης εναποτίθεται διαδοχικά και ελεγχόμενα στην πλατφόρμα εκτύπωσης και γ) οι συσκευές που απαιτούνται για τη διεκπεραίωση της κατασκευής είναι πολύ απλές (ένας υπολογιστής και ένας εκτυπωτής), ενώ δεν γίνεται χρήση περίπλοκων μηχανών και συνηθισμένων εργαλείων. Το γεγονός αυτό επιτρέπει την εγκατάσταση μικρών μονάδων παραγωγής ακόμη και σε απομακρυσμένα μέρη. Επιπρόσθετα, η χρήση της Προσθετικής Κατασκευής για την κατασκευή μικροβελόνων επιτρέπει κατά περιπτώσεις την εξατομικευμένη χορήγηση φαρμάκων.Σκοπός της παρούσας διδακτορικής διατριβής ήταν η αξιοποίηση της Προσθετικής Κατασκευής και των πλεονεκτημάτων που προσφέρει με στόχο αφενός την κατασκευή συστοιχιών μικροβελόνων και αφετέρου τη χρήση αυτών για χορήγηση μακρομοριακών φαρμακευτικών ουσιών. Αρχικά η μελέτη επικεντρώθηκε στην κατασκευή των μικροβελόνων. Κατασκευάστηκαν δύο είδη μικροβελόνων: α) συμπαγείς (solid) μικροβελόνες με χρήση στερεολιθογραφίας (stereolithography, SLA) και β) κοίλες μικροβελόνες (HMNs) με εκτύπωση μέσω οθόνης υγρών κρυστάλλων (liquid crystal display, LCD). Σε κάθε περίπτωση οι μικροβελόνες προσδιορίστηκαν ως προς τη μορφολογία και τις διαστάσεις τους με χρήση οπτικής μικροσκοπίας και ηλεκτρονικού μικροσκοπίου σάρωσης (scanning electron microscopy, SEM). Επιπρόσθετα, έγινε μελέτη των μηχανικών τους ιδιοτήτων μέσω δοκιμών μονοαξονικής θλίψης, ενώ ακόμη έγιναν δοκιμές διείσδυσης σε δείγματα δέρματος ανθρώπινης προέλευσης. Παράλληλα, οι δοκιμές μονοαξονικής θλίψης και διείσδυσης προσομοιώθηκαν μέσω ανάλυσης πεπερασμένων στοιχείων (Finite Element Analysis, FEA). Οι συμπαγείς μικροβελόνες (6x6) χρησιμοποιήθηκαν για τη διαδερμική χορήγηση των πρότυπων χρωστικών καλσεΐνη και FITC-Dextran (4000Da). Ακολούθως έγινε επεξεργασία των αποτελεσμάτων διαπερατότητας και υπολογίστηκε η αύξηση της διαπερατότητας του δέρματος για κάθε χρωστική έπειτα από τη μεσολάβηση των μικροβελόνων. Στα δείγματα δέρματος που χρησιμοποιήθηκαν σε αυτά τα πειράματα έγιναν τομές με κρυοστάτη και χρώση αιματοξυλίνης-εοσίνης.Οι HMNs κατασκευάστηκαν αρχικά ως 3x3 συστοιχίες υπό γεωμετρία κυρτής τριγωνικής πυραμίδας. Ακολούθως μελετήθηκε η ικανότητα διάβασης υδατικού μέσου από τα μικροκανάλια και έτσι διαπιστώθηκε η ανάγκη προσθήκης επιφανειοδραστικού παράγοντα στην επιφάνεια των μικροβελόνων. Η επικάλυψη έγινε με 5% Pluronic F-127 και η προσθήκη του επιβεβαιώθηκε με φάσμα FTIR και μελέτη γωνίας επαφής. Για τις ανάγκες της χορήγησης κατασκευάστηκαν δεξαμενές με κατασκευή μέσω μοντελοποίησης απόθεσης τήγματος (fused deposition modeling, FDM). Οι δεξαμενές συναρμολογήθηκαν με τις μικροβελόνες δίνοντας την τελική συσκευή χορήγησης. Στη συνέχεια διεξήχθησαν μελέτες διαπερατότητας μέσω συνθετικών μεμβρανών χρησιμοποιώντας οξική οκτρεοτίδη. Ακόμη, χρησιμοποιώντας εκχυλίσματα τρισδιάστατα εκτυπωμένου υλικού έγιναν μελέτες τοξικότητας σε HaCaT κυτταρικές σειρές. Σε επόμενο στάδιο σχεδιάστηκε μια παραλλαγή των παραπάνω συστοιχιών και κατασκευάστηκαν 6x6 συστοιχίες μικροβελόνων της ίδιας γεωμετρίας. Επιπρόσθετα, κατασκευάστηκαν 6x6 συστοιχίες μικροβελόνων γεωμετρίας σύριγγας (syringe-like), καθώς και ρεζερβουάρ κατασκευασμένα με LCD μέθοδο. Έπειτα από προσθήκη επιφανειοδραστικού και διεξαγωγή υπολογιστικής μαγνητικής τομογραφίας (μ-OCT) όπου προσδιορίστηκαν οι εσωτερικοί όγκοι των μικροκαναλιών, τα δύο είδη μικροβελόνων χρησιμοποιήθηκαν για in vitro διαδερμική χορήγηση ινσουλίνης.Τα αποτελέσματα της έρευνας έδειξαν ότι οι μικροβελόνες που κατασκευάστηκαν ήταν κατάλληλες για διάτρηση του δέρματος καθώς και συνθετικών μεμβρανών. Διαστασιολογικά οι μικροβελόνες κυμαίνονται εντός των ορίων που εξασφαλίζουν την ανώδυνη εφαρμογή τους. Η μηχανική αντοχή τους επιτρέπει τη χρήση για την οποία προορίζονται χωρίς να υπάρχει κίνδυνος θραύσης και παραμονής τμήματος των μικροβελόνων εντός των ιστών του δέρματος, με συντελεστή ασφαλείας (safety factor) πολύ μεγαλύτερο της μονάδας και με τα αποτελέσματα FEA να είναι σε συμφωνία με τα πειραματικά δεδομένα. Η προσθήκη του επιφανειοδραστικού παράγοντα στις HMNs ήταν επιτυχής και επέτρεψε την ελεύθερη δίοδο υδατικών διαλυμάτων δραστικών ουσιών. Η κατασκευή των ρεζερβουάρ ήταν επίσης επιτυχής και απέδωσε τις επιθυμητές διαστάσεις, επιτρέποντας έτσι τη συναρμολόγηση των ρεζερβουάρ με τις HMNs χωρίς να σημειώνονται διαρροές. Σε όλες τις περιπτώσεις πειραμάτων διαπερατότητας παρατηρήθηκε αύξηση της ποσότητας δραστικής ουσίας που διαπερνά το δέρμα ή τις συνθετικές μεμβράνες έπειτα από τη μεσολάβηση των μικροβελόνων. Ακόμη, οι τοξικολογικές μελέτες έδειξαν ότι η τρισδιάστατα εκτυπωμένη ρητίνη είναι ασφαλής για ολιγόλεπτη επαφή με το δέρμα. Στην παρούσα διδακτορική διατριβή αποδείχθηκε ότι η Προσθετική Κατασκευή είναι κατάλληλη για κατασκευή μικροβελόνων και συνεπώς δίνεται η δυνατότητα να αξιοποιηθούν τα πλεονεκτήματα που προσφέρει ως μέθοδος. Επίσης, κατόπιν αποτελεσματικής διάτρησης του δέρματος, αποδείχθηκε ότι είναι εφικτή η διαδερμική χορήγηση φαρμάκων μεγάλου μοριακού βάρους (ενδεικτικά εδώ FITC-Dextran 4000Da, οξική οκτρεοτίδη, ινσουλίνη). Εν κατακλείδι, οι τρισδιάστατα εκτυπωμένες μικροβελόνες είναι κατάλληλες για διαδερμική χορήγηση μακρομορίων.


Nanomaterials ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 446
Author(s):  
Ioannis Spanos ◽  
Zacharias Vangelatos ◽  
Costas Grigoropoulos ◽  
Maria Farsari

The need for control of the elastic properties of architected materials has been accentuated due to the advances in modelling and characterization. Among the plethora of unconventional mechanical responses, controlled anisotropy and auxeticity have been promulgated as a new avenue in bioengineering applications. This paper aims to delineate the mechanical performance of characteristic auxetic and anisotropic designs fabricated by multiphoton lithography. Through finite element analysis the distinct responses of representative topologies are conveyed. In addition, nanoindentation experiments observed in-situ through scanning electron microscopy enable the validation of the modeling and the observation of the anisotropic or auxetic phenomena. Our results herald how these categories of architected materials can be investigated at the microscale.


2021 ◽  
Vol 3 (1) ◽  
Author(s):  
Xiaodong He ◽  
Christopher-Denny Matte ◽  
Tsz-Ho Kwok

AbstractThe paper presents a novel manufacturing approach to fabricate origami based on 3D printing utilizing digital light processing. Specifically, we propose to leave part of the model uncured during the printing step, and then cure it in the post-processing step to set the shape in a folded configuration. While the cured regions in the first step try to regain their unfolded shape, the regions cured in the second step attempt to keep their folded shape. As a result, the final shape is obtained when both regions’ stresses reach equilibrium. Finite element analysis is performed in ANSYS to obtain the stress distribution on common hinge designs, demonstrating that the square-hinge has a lower maximum principal stress than elliptical and triangle hinges. Based on the square-hinge and rectangular cavity, two variables—the hinge width and the cavity height—are selected as principal variables to construct an empirical model with the final folding angle. In the end, experimental verification shows that the developed method is valid and reliable to realize the proposed deformation and 3D development of 2D hinges.


2011 ◽  
Author(s):  
David Fornaro

Finite Element Analysis (FEA) is mature technology that has been in use for several decades as a tool to optimize structures for a wide variety of applications. Its application to composite structures is not new, however the technology for modeling and analyzing the behavior of composite structures continues to evolve on several fronts. This paper provides a review of the current state-of-the-art with regard to composites FEA, with a particular emphasis on applications to yacht structures. Topics covered are divided into three categories: Pre-processing; Postprocessing; and Non-linear Solutions. Pre-processing topics include meshing, ply properties, laminate definitions, element orientations, global ply tracking and load case development. Post-processing topics include principal stresses, failure indices and strength ratios. Nonlinear solution topics include progressive ply failure. Examples are included to highlight the application of advanced finite element analysis methodologies to the optimization of composite yacht structures.


2021 ◽  
Vol 24 (2) ◽  
Author(s):  
Tarcisio José de Arruda Paes Junior ◽  
João Paulo Mendes Tribst ◽  
Amanda Maria de Oliveira Dal Piva ◽  
Viviane Maria Gonçalves de Figueiredo ◽  
Alexandre Luiz Souto Borges ◽  
...  

Purpose: To evaluate the effect of fibromucosa height on the stress distribution and displacement of mandibular total prostheses during posterior unilateral load, posterior bilateral load and anterior guidance using the finite element analysis (FEA). Material and methods: 3D virtual models were made to simulate the stress generated during different mandibular movements in a total prosthesis. The contacts were simulated according to the physiology, being considered perfectly bonded between cortical and medullar bones; and between cortical bone and mucosa. Non-linear frictional contact was used for the total prosthesis base and fibromucosa, allowing the prosthesis to slide over the tissue. The cortical bone base was fixed and the 100 N load was applied as unilateral load, posterior bilateral load and anterior guidance simulation. The required results were for maximum principal stress (MPa), microstrain (mm/mm) and total displacement (mm). The numerical results were converted into colorimetric maps and arranged according to corresponding scales. Results: The stress generated in all situations was directly proportional to the fibromucosa height. The maximum principal stress results demonstrated greater magnitude for anterior guidance, posterior unilateral and posterior bilateral, respectively. Only posterior unilateral load demonstrated an increase in bone microstrain, regardless of the fibromucosa height. Prosthesis displacement was lower under posterior bilateral loading. Conclusion: Posterior bilateral loading is indicated for total prosthesis because it allows lower prosthesis displacement, lower stress concentration at the base of the prosthesis and less bone microstrain.   Keywords Finite element analysis; Occlusion; Total prosthesis.


2007 ◽  
Vol 07 (04) ◽  
pp. 419-431
Author(s):  
SATYA PRASAD PARUCHURU ◽  
ANUJ JAIN ◽  
XIAODU WANG

It is well understood that bone quality deteriorates due to aging, disease, etc., and may be affected by factors at different length scales due to its hierarchical microstructure. Fracture toughness is one of the properties that assess bone quality. The compact sandwich (CS) specimen gives a better choice of bone sample size, and therefore suits a wide variety of fracture toughness testing needs and constraints. Reliable and statistically valid overall CS specimen size requirements are established in this paper; these serve as guidelines for choosing the CS specimen size. Finite element analysis (FEA) is used for simulating fracture toughness tests. Experimental fracture toughness tests are carried out to verify the FEA results. The experimental results are verified qualitatively by performing scanning electron microscopy (SEM) on the fractured specimen surfaces.


2013 ◽  
Vol 710 ◽  
pp. 243-246
Author(s):  
Xian Hong Yang

The use of Pro/E and their respective advantages ANSYS software product design and engineering analysis to solve the case, first of all in the Pro/E, the completion of three-dimensional helical gear design, and then in the Pro/MECHANICA completed finite element model of helical gear, and then into ANSYS for finite element analysis of bevel gear calculation and simulation, finite element analysis of the final results of optimization design model is presented recommendations for improvement. The product design and engineering analysis method has some reference value in engineering design.


Sign in / Sign up

Export Citation Format

Share Document