scholarly journals THE INFLUENCE OF SLOW RECOVERY INSOLE ON PLANTAR PRESSURE AND CONTACT AREA DURING WALKING

2015 ◽  
Vol 15 (02) ◽  
pp. 1540005
Author(s):  
ROOZBEH NAEMI ◽  
KIMBERLEY LINYARD-TOUGH ◽  
AOIFE HEALY ◽  
NACHIAPPAN CHOCKALINGAM

Plantar pressure assessment is commonly used as a tool to assess the efficacy of insoles in reducing the risk of mechanical trauma to the plantar soft tissue during walking gait. The slow rebound (SR) Poron insole is intended to provide a custom fit to the foot and is believed to be superior in increasing the contact area and consequently reducing the contact pressure compared to a normal Poron (NP) insole. The aim of this study was to compare the effectiveness of SR or NP versus an ethylene vinyl acetate (EV) insole in increasing the contact area (CA), and in reducing the contact pressure (CP) at different regions of the foot during walking. Plantar pressure data was collected from nine healthy individuals during walking using commercially available in-shoe plantar pressure sensors. Although, the NP insole significantly increased the CA and decreased the CP on the entire foot compared to the EV, there was no significant change in CP or CA at any region of the foot in any of the tested insoles. CP showed a positive significant correlation with CA at heel, hallux and heel center in all three insoles. The expected significant negative correlation between regional CA and CP was not observed.

1995 ◽  
Vol 23 (4) ◽  
pp. 238-255 ◽  
Author(s):  
E. H. Sakai

Abstract The contact conditions of a tire with the road surface have a close relationship to various properties of the tire and are among the most important characteristics in evaluating the performance of the tire. In this research, a new measurement device was developed that allows the contact stress distribution to be quantified and visualized. The measuring principle of this device is that the light absorption at the interface between an optical prism and an evenly ground or worn rubber surface is a function of contact pressure. The light absorption can be measured at a number of points on the surface to obtain the pressure distribution. Using this device, the contact pressure distribution of a rubber disk loaded against a plate was measured. It was found that the pressure distribution was not flat but varied greatly depending upon the height and diameter of the rubber disk. The variation can be explained by a “spring” effect, a “liquid” effect, and an “edge” effect of the rubber disk. Next, the measurement and image processing techniques were applied to a loaded tire. A very high definition image was obtained that displayed the true contact area, the shape of the area, and the pressure distribution from which irregular wear was easily detected. Finally, the deformation of the contact area and changes in the pressure distribution in the tread rubber block were measured when a lateral force was applied to the loaded tire.


2020 ◽  
Vol 5 (4) ◽  
pp. 2473011420S0025
Author(s):  
Zhao Hong-Mou

Category: Ankle; Basic Sciences/Biologics Introduction/Purpose: To study the effect of different degrees of distal tibial varus and valgus deformities on the tibiotalar joint contact, and to understand the role of fibular osteotomy. Methods: Eight cadaveric lower legs were used for biomechanical study. Nine conditions were included: normal ankle joint (group A), 10° varus (group B), 5° varus (group C), 5° valgus (group D), 10° valgus (group E) with fibular preserved, and 10° varus (group F), 5° varus (group G), 5° valgus (group H), and 10° valgus (group I) after fibular osteotomy. The joint contact area, contact pressure, and peak pressure were tested; and the translation of contact force center was observed. Results: The joint contact area, contact pressure, and peak pressure had no significant difference between group A and groups B to E (P>0.05). After fibular osteotomy, the contact area decreased significantly in groups F and I when compared with group A (P<0.05); the contact pressure increased significantly in groups F, H, and I when compared with group A (P<0.05); the peak pressure increased significantly in groups F and I when compared with group A (P<0.05). There were two main anterior-lateral and anterior-medial contact centers in normal tibiotalar joint, respectively; and the force center was in anterior-lateral part, just near the center of tibiotalar joint. While the fibula was preserved, the force center transferred laterally with increased varus angles; and the force center transferred medially with increased valgus angles. However, the force center transferred oppositely to the medial part with increased varus angles, and laterally with increased valgus angles after fibular osteotomy. Conclusion: Fibular osteotomy facilitates the tibiotalar contact pressure translation, and is helpful for ankle joint realignment in suitable cases.


Sensors ◽  
2021 ◽  
Vol 21 (6) ◽  
pp. 2246
Author(s):  
Scott Pardoel ◽  
Gaurav Shalin ◽  
Julie Nantel ◽  
Edward D. Lemaire ◽  
Jonathan Kofman

Freezing of gait (FOG) is a sudden and highly disruptive gait dysfunction that appears in mid to late-stage Parkinson’s disease (PD) and can lead to falling and injury. A system that predicts freezing before it occurs or detects freezing immediately after onset would generate an opportunity for FOG prevention or mitigation and thus enhance safe mobility and quality of life. This research used accelerometer, gyroscope, and plantar pressure sensors to extract 861 features from walking data collected from 11 people with FOG. Minimum-redundancy maximum-relevance and Relief-F feature selection were performed prior to training boosted ensembles of decision trees. The binary classification models identified Total-FOG or No FOG states, wherein the Total-FOG class included data windows from 2 s before the FOG onset until the end of the FOG episode. Three feature sets were compared: plantar pressure, inertial measurement unit (IMU), and both plantar pressure and IMU features. The plantar-pressure-only model had the greatest sensitivity and the IMU-only model had the greatest specificity. The best overall model used the combination of plantar pressure and IMU features, achieving 76.4% sensitivity and 86.2% specificity. Next, the Total-FOG class components were evaluated individually (i.e., Pre-FOG windows, Freeze windows, transition windows between Pre-FOG and Freeze). The best model detected windows that contained both Pre-FOG and FOG data with 85.2% sensitivity, which is equivalent to detecting FOG less than 1 s after the freeze began. Windows of FOG data were detected with 93.4% sensitivity. The IMU and plantar pressure feature-based model slightly outperformed models that used data from a single sensor type. The model achieved early detection by identifying the transition from Pre-FOG to FOG while maintaining excellent FOG detection performance (93.4% sensitivity). Therefore, if used as part of an intelligent, real-time FOG identification and cueing system, even if the Pre-FOG state were missed, the model would perform well as a freeze detection and cueing system that could improve the mobility and independence of people with PD during their daily activities.


Author(s):  
T Stewart ◽  
Z M Jin ◽  
D Shaw ◽  
D D Auger ◽  
M Stone ◽  
...  

The tibio-femoral contact area in five current popular total knee joint replacements has been measured using pressure-sensitive film under a normal load of 2.5 kN and at several angles of flexion The corresponding maximum contact pressure has been estimated from the measured contact areas and found to exceed the point at which plastic deformation is expected in the ultra-high molecular weight polyethylene (UHMWPE) component particularly at flexion angles near 90°. The measured contact area and the estimated maximum contact stress have been found to be similar in magnitude for all of the five knee joint replacements tested. A significant difference, however, has been found in maximum contact pressure predicted from linear elasticity analysis for the different knee joints. This indicates that varying amounts of plastic deformation occurred in the polyethylene component in the different knee designs. It is important to know the extent of damage as knees with large amounts of plastic deformation are more likely to suffer low cycle fatigue failure. It is therefore concluded that the measurement of contact areas alone can be misleading in the design of and deformation in total knee joint replacements. It is important to modify geometries to reduce the maximum contact stress as predicted from the linear elasticity analysis, to below the linear elastic limit of the plastic component.


2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Eung Tae Kim ◽  
Sungmin Kim

AbstractA smart insole system consisting of pressure sensors, wireless communication modules, and pressure monitoring software has been developed to measure plantar pressure distribution that appears in sewing process. This system calculates the cycle time of each operation by analyzing the real-time plantar pressure data. The operation cycle time was divided into the time done by machine and by manual and calculated by adding the two types of time. By analyzing the cycle time, it is possible to estimate the type of operation a worker is performing. The ability to calculate accurate cycle time and to manage a large volume of data is the advantage of this system. Establishing an accurate cycle time of all operations would be of great help in improving the production process, capacity planning, line efficiency, and labor cost calculation. The system is expected to be a good alternative to the conventional manual measurement process. It will also be able to meet the high demand from garment manufacturers for automated monitoring systems.


Healthcare ◽  
2020 ◽  
Vol 8 (4) ◽  
pp. 523
Author(s):  
Hui-Ling Lin ◽  
Yu-Chi Lee ◽  
Ssu-Hui Wang ◽  
Li-Ying Chiang ◽  
Jui-Fang Liu

Background: The aim of this study was to evaluate the effect of a newly designed foam cushion on the air leakage and pressure when applied to the face. Methods: A teaching manikin connected to a bilevel positive airway pressure ventilator attached to four different brands of oronasal masks (Amara, Mirage, Forma, and Wizard) was used. The foam cushions of 5-mm and 10-mm-thickness were attached to the masks, and each mask was tested without a cushion. Six pressure sensors were placed on the manikin’s face, and data were recorded. Inspiratory volume and air leak flow from the ventilator were observed. Results: Air leakage was influenced by both the mask brand and the presence of a cushion. The presence of a cushion did not affect the Wizard mask in terms of leakage (p = 0.317) or inspiratory volume (p = 0.726). The Wizard and Amara masks generated the lowest contact pressure on the frontal forehead (p < 0.001) compared to the other five points. Conclusions: Utilisation of a cushion reduces air leakage and maintains greater inspiratory volume regardless of its thickness. The contact pressure varies depending on the brand of the mask, which would require a difference in the thickness of the cushion for pressure reduction.


2005 ◽  
Vol 128 (2) ◽  
pp. 230-235 ◽  
Author(s):  
J. Jamari ◽  
D. J. Schipper

In this paper we report the experimental investigation to evaluate the published models for the contact of a deformable sphere against a hard flat in the fully plastic contact regime. A new measurement method has been used to measure the contact area. The behavior of the mean contact pressure and the contact area as a function of the contact load are presented. Substantial differences are found between the measurements and the model predictions. A constant value of the mean contact pressure as the load increases is observed, however, the value is lower than the hardness, as often reported. The contact area is found to be a simple truncation of the sphere by a hard flat.


2016 ◽  
Vol 40 (3) ◽  
pp. 265-278 ◽  
Author(s):  
Reginaldo Barboza da Silva ◽  
Piero Iori ◽  
Zigomar Menezes de Souza ◽  
Danilo de Moraes Gomes Pereira ◽  
Oswaldo Julio Vischi Filho ◽  
...  

ABSTRACT High contact pressures applied to soil result in a greater degree of compaction, in addition to promoting other negative effects. The objective of this study was to quantify contact areas by using different methodologies, and pressures of farm equipment employed in production activity and evaluate structural changes caused in a Red Latosol with the presence and absence of straw cover. The design was completely randomized in a factorial scheme of type 4 (tire on front axle, tire on rear axle, tire on a sugarcane wagon and metallic track of sugar cane Harvester) x 2 (presence and absence of straw). The contact area (CA) of the run was obtained by three procedures: analytical measure of the area of an ellipse (CA1); digital measurement of area of an ellipse (CA2); and measurement of real contact area (RCA), with digital resources. The contact pressure was calculated from the ratio of mass of each machine's axle and the contact area of the run. The contact area obtained according to the procedure of the ellipse (CA1 and CA2) is overrated when compared to actual area obtained digitally (RCA). The straw reduces the contact pressure in the soil, due to the deep tire treads and consequently, increased contact area. Areas where the traffic of the machines occurred with soil covered with the presence of straw showed reduced soil resistance to penetration, cone index and pre-consolidation pressure, confirming that the increased contact area produced by straw reduced the pressure applied and the compression power dissipated in the soil.


Sign in / Sign up

Export Citation Format

Share Document