Comparison of maximal oxygen uptake values determined by predicted and actual methods

1965 ◽  
Vol 20 (3) ◽  
pp. 509-513 ◽  
Author(s):  
R. G. Glassford ◽  
G. H. Y. Baycroft ◽  
A. W. Sedgwick ◽  
R. B. J. Macnab

Twenty-four male subjects aged 17–33 were given three direct tests of maximal oxygen uptake and one indirect test. The direct tests were those of Mitchell, Sproule, and Chapman (treadmill); Taylor, Buskirk, and Henschel (treadmill); and Åstrand (bicycle ergometer). The indirect test was the Åstrand-Ryhming nomogram (bicycle ergometer) employing heart rate response to submaximal work. In addition, the Johnson, Brouha, and Darling physical fitness test was administered. The two treadmill tests and the indirect test yielded significantly higher mean values than did the direct bicycle test. However no other significant differences in mean values occurred. Correlation coefficients between the various oxygen uptake tests as well as the fitness test were all found to be significant (.62–.83), i.e., greater than zero. No correlation obtained proved to be significantly greater than any other. The results indicate that direct treadmill tests, employing greater muscle mass, yield higher maximal oxygen uptake values (8%) than does the direct bicycle ergometer test. The Åstrand-Ryhming nomogram appears to produce a good estimation of maximal oxygen uptake, in a population unaccustomed to cycling. erobic capacity; exercise; heart rate Submitted on September 17, 1964

1961 ◽  
Vol 16 (6) ◽  
pp. 977-981 ◽  
Author(s):  
Per-Olof 0Åstrand ◽  
Bengt Saltin

Seven subjects performed maximal work of various types. The following exercises were studied: a) cycling a bicycle ergometer in a sitting and b) supine position, c) simultaneous arm and leg work on bicycle ergometers, d) running on a treadmill, e) skiing, f) swimming, and g) arm work (cranking). Vo2 was a few per cent higher in running uphill than in cycling ( a), cranking plus cycling ( c), and skiing, in which events similar values were attained. Heart rate was similar in those types of exercise mentioned ( a, c, d, e). Supine cycling ( b) gave a maximal Vo2 that was about 15% lower than in sitting cycling. A similar reduction in maximal Vo2 was noted in swimming. Maximal work with the arms ( g) gave an oxygen uptake that was about 70% of maximal Vo2 when cycling ( a). It is concluded that the aerobic capacity and maximal heart rate are the same in maximal running or cycling, at least in well-trained subjects. Submitted on June 23, 1961


1993 ◽  
Vol 5 (4) ◽  
pp. 357-366 ◽  
Author(s):  
Hazzaa M. Al-Hazzaa ◽  
Mohammed A. Sulaiman

The present study examined the relationship between maximal oxygen uptake (V̇O2max) and daily physical activity in a group of 7- to 12-year-old boys. V̇O2max was assessed through the incremental treadmill test using an open circuit system. Physical activity level was obtained from heart rate telemetry outside of school time for 8 hrs during weekdays and during 40 min of physical education classes. The findings indicated that the absolute value of V̇O2max increased with age, while relative to body weight it remained almost the same across age, with a mean of 48.4 ml · kg−1 · min−1. Moreover, heart rate telemetry showed that the boys spent a limited amount of time on activities that raise the heart rate to a level above 160 bpm (an average of 1.9%). In addition, V̇O2max was found to be significantly related to the percentage of time spent at activity levels at or above a heart rate of 140 bpm, but not with activity levels at or above a heart rate of 160 bpm.


2021 ◽  
Author(s):  
Ryan Palmer ◽  
Mark DeBeliso

The United States Army recently implemented the Army Combat Fitness Test (ACFT) which was designed to more accurately measure functional-combat fitness constructs. The ACFT replaced the former Army Physical Fitness Test (APFT). The three advent APFT consisted of: two-minute push-ups (PU), two-minute sit-ups (SU), and a timed two-mile run (RUN). The ACFT consists of six events; 3 Rep Max Deadlift (MDL), Standing Power Throw (SPT), Hand Release Push-up (HRP), Sprint-Drag-Carry (SDC), Hanging Leg Tuck (LTK), and a timed two-mile run (2MR). This study investigated the relationship between Soldier height and body mass kg on ACFT scores of 655 male U.S. Army National Guard Soldiers in a Field Artillery Brigade. For the purpose of the investigation body mass index (BMI) was calculated as the metric representing the Soldier(s) height and weight. The mean and standard deviation (sd) were calculated for the ACFT event and total scores. Pearson correlation coefficients (PCCs or r) were calculated between BMI and ACFT event and total scores. Likewise, PCCs were calculated between the ACFT event and total scores. The ACFT mean(sd) scores were as follows: MDL=92.2(31.8) (3 maximum repetitions), SPT=9.5(2.2) (meters), HRP=24.6(13.1) (repetitions), SDC=119.8(21.7) (seconds), LTK=6.2(5.4) (repetitions), 2MR=1095.0(233.7) (seconds), ACFT total score=442.3(54.4) (points). Significant positive correlations were found between the ACFT total score: MDL (r=0.70), SPT (r=0.50), HRP (r=0.74), and LTK (r=0.76) events. Conversely, significant negative correlations were identified between ACFT total score: SDC (r=-0.68) and 2MR (r=-0.53) events. Within the parameters of this study, Soldier BMI demonstrated no to weak association with individual ACFT event or ACFT total scores. Further, the range of PCCs between the ACFT event scores were no to moderately high. Military leaders may consider the results provided as combat and fitness tests continue to evolve.


2017 ◽  
Author(s):  
Victoria Mazoteras Pardo ◽  
Marta E Losa Iglesias ◽  
José López Chicharro ◽  
Ricardo Becerro de Bengoa Vallejo

BACKGROUND Self-measurement of blood pressure is a priority strategy for managing blood pressure. OBJECTIVE The aim of this study was to evaluate the reliability and validity of blood pressure and heart rate following the European Society of Hypertension’s international validation protocol, as measured with the QardioArm, a fully automatic, noninvasive wireless blood pressure monitor and mobile app. METHODS A total of 100 healthy volunteers older than 25 years from the general population of Ciudad Real, Spain, participated in a test-retest validation study with two measurement sessions separated by 5 to 7 days. In each measurement session, seven systolic blood pressure, diastolic blood pressure, and heart rate assessments were taken, alternating between the two devices. The test device was the QardioArm and the previously validated criterion device was the Omron M3. Sessions took place at a single study site with an evaluation room that was maintained at an appropriate temperature and kept free from noises and distractions. RESULTS The QardioArm displayed very consistent readings both within and across sessions (intraclass correlation coefficients=0.80-0.95, standard errors of measurement=2.5-5.4). The QardioArm measurements corresponded closely to those from the criterion device (r>.96) and mean values for the two devices were nearly identical. The QardioArm easily passed all validation standards set by the European Society of Hypertension International Protocol. CONCLUSIONS The QardioArm mobile app has validity and it can be used free of major measurement error.


2006 ◽  
Vol 31 (5) ◽  
pp. 541-548 ◽  
Author(s):  
Adrian W. Midgley ◽  
Lars R. McNaughton ◽  
Sean Carroll

This study investigated the utility of a verification phase for increasing confidence that a “true” maximal oxygen uptake had been elicited in 16 male distance runners (mean age (±SD), 38.7  (± 7.5 y)) during an incremental treadmill running test continued to volitional exhaustion. After the incremental test subjects performed a 10 min recovery walk and a verification phase performed to volitional exhaustion at a running speed 0.5 km·h–1 higher than that attained during the last completed stage of the incremental phase. Verification criteria were a verification phase peak oxygen uptake ≤ 2% higher than the incremental phase value and peak heart rate values within 2 beats·min–1 of each other. Of the 32 tests, 26 satisfied the oxygen uptake verification criterion and 23 satisfied the heart rate verification criterion. Peak heart rate was lower (p = 0.001) during the verification phase than during the incremental phase, suggesting that the verification protocol was inadequate in eliciting maximal values in some runners. This was further supported by the fact that 7 tests exhibited peak oxygen uptake values over 100 mL·min–1 (≥ 3%) lower than the peak values attained in the incremental phase. Further research is required to improve the verification procedure before its utility can be confirmed.


1975 ◽  
Vol 39 (1) ◽  
pp. 135-144 ◽  
Author(s):  
B. J. Clark ◽  
R. F. Coburn

Changes in intracellular Po2 in myoglobin containing skeletal muscle during exercise were estimated in normal nonathlete subjects from measurements of shifts of CO between blood and muscle under conditions where the total body CO stores remained constant. Exercise was performed on a bicycle ergometer. In 1.5–2 and 6–7 min runs at Vo2 max with the subject breathing 21% O2, mean MbCO/HbCO increased 146 +/- 7 and 163 +/- 11% of resting values, respectively (P less than 0.05). With the subjects breathing 13–14% O2, in 1.5–2 and 6–7 min runs, Vo2 max fell an average of 4.3 +/- 5.1% and 12.0 +/- 5.2%, respectively, and mean MbCO/HbCO increased to 233 +/- 18% and 210 +/- 52% of resting value, respectively (P less than 0.05). These findings suggest that mean myoglobin Po2 fell during exercise at Vo2 max, with the subjects breathing 21% O2 and the decrease in mean myoglobin Po2 was greater with the subject breathing 13–14% O2. There was considerable variability in different subjects and in some, the data were not consistent with intracellular O2 availability limiting aerobic metabolism. The data support a postulate that there are several limiting factors for the aerobic capacity, including intracellular O2 availability.


2017 ◽  
Vol 21 (1) ◽  
pp. 31-41
Author(s):  
Michael J. Mazzoleni ◽  
Claudio L. Battaglini ◽  
Kerry J. Martin ◽  
Erin M. Coffman ◽  
Jordan A. Ekaidat ◽  
...  

1996 ◽  
Vol 82 (2) ◽  
pp. 419-424 ◽  
Author(s):  
Antonios K. Travlos ◽  
Daniel Q. Marisi

This study was conducted to investigate the influence of fitness level and gradually increased amounts of exercise on individuals' ratings of perceived exertion (RPE). 20 men served as paid subjects. They were divided into groups of high (>56 ml/kg/min.) and low fitness (<46 ml/kg/min.) according to their maximal oxygen uptake (VO2 max). Participants were required to pedal on a cycle ergometer at a progressively increased workload (every 10 min.) corresponding to 40, 50, 60, 70, and 80% of individual VO2 max values. Heart rates, RPE, and core temperatures were recorded every 5th minute after the initiation of exercising at a specific workload. Analysis indicated that, when controlling for VO2 max values, elevations of heart rate and core temperature were not affected by fitness. However, highly fit individuals perceived themselves under less exertion than did the group low in fitness. Correlations showed that, taking into consideration fitness, there is a stronger relationship between RPE and heart rate and RPE and core temperature for the highly fit individuals than for the less fit.


Sign in / Sign up

Export Citation Format

Share Document