scholarly journals Multiple Sensory Cues Underlying the Perception of Translation and Path

2007 ◽  
Vol 97 (2) ◽  
pp. 1100-1113 ◽  
Author(s):  
N. Au Yong ◽  
G. D. Paige ◽  
S. H. Seidman

The translational linear vestibuloocular reflex compensates most accurately for high frequencies of head translation, with response magnitude decreasing with declining stimulus frequency. However, studies of the perception of translation typically report robust responses even at low frequencies or during prolonged motion. This inconsistency may reflect the incorporation of nondirectional sensory information associated with the vibration and noise that typically accompany translation, into motion perception. We investigated the perception of passive translation in humans while dissociating nondirectional cues from actual head motion. In a cue-dissociation experiment, interaural (IA) motion was generated using either a linear sled, the mechanics of which generated noise and vibration cues that were correlated with the motion profile, or a multiaxis technique that dissociated these cues from actual motion. In a trajectory-shift experiment, IA motion was interrupted by a sudden change in direction (±30° diagonal) that produced a change in linear acceleration while maintaining sled speed and therefore mechanical (nondirectional) cues. During multi-axis cue-dissociation trials, subjects reported erroneous translation perceptions that strongly reflected the pattern of nondirectional cues, as opposed to nearly veridical percepts when motion and nondirectional cues coincided. During trajectory-shift trials, subjects' percepts were initially accurate, but erroneous following the direction change. Results suggest that nondirectional cues strongly influence the perception of linear motion, while the utility of cues directly related to translational acceleration is limited. One key implication is that “path integration” likely involves complex mechanisms that depend on nondirectional and contextual self-motion cues in support of limited and transient otolith-dependent acceleration input.

2021 ◽  
Vol 12 ◽  
Author(s):  
Florian Denk ◽  
Michael Kohnen ◽  
Josep Llorca-Bofí ◽  
Michael Vorländer ◽  
Birger Kollmeier

Generations of researchers observed a mismatch between headphone and loudspeaker presentation: the sound pressure level at the eardrum generated by a headphone has to be about 6 dB higher compared to the level created by a loudspeaker that elicits the same loudness. While it has been shown that this effect vanishes if the same waveforms are generated at the eardrum in a blind comparison, the origin of the mismatch is still unclear. We present new data on the issue that systematically characterize this mismatch under variation of the stimulus frequency, presentation room, and binaural parameters of the headphone presentation. Subjects adjusted the playback level of a headphone presentation to equal loudness as loudspeaker presentation, and the levels at the eardrum were determined through appropriate transfer function measurements. Identical experiments were conducted at Oldenburg and Aachen with 40 normal-hearing subjects including 14 that passed through both sites. Our data verify a mismatch between loudspeaker and binaural headphone presentation, especially at low frequencies. This mismatch depends on the room acoustics, and on the interaural coherence in both presentation modes. It vanishes for high frequencies and broadband signals if individual differences in the sound transfer to the eardrums are accounted for. Moreover, small acoustic and non-acoustic differences in an anechoic reference environment (Oldenburg vs. Aachen) exert a large effect on the recorded loudness mismatch, whereas not such a large effect of the respective room is observed across moderately reverberant rooms at both sites. Hence, the non-conclusive findings from the literature appear to be related to the experienced disparity between headphone and loudspeaker presentation, where even small differences in (anechoic) room acoustics significantly change the response behavior of the subjects. Moreover, individual factors like loudness summation appear to be only loosely connected to the observed mismatch, i.e., no direct prediction is possible from individual binaural loudness summation to the observed mismatch. These findings – even though not completely explainable by the yet limited amount of parameter variations performed in this study – have consequences for the comparability of experiments using loudspeakers with conditions employing headphones or other ear-level hearing devices.


Author(s):  
Alex F. Lim ◽  
Jonathan W. Kelly ◽  
Nathan C. Sepich ◽  
Lucia A. Cherep ◽  
Grace C. Freed ◽  
...  

2015 ◽  
Vol 804 ◽  
pp. 25-29 ◽  
Author(s):  
Wanlop Harnnarongchai ◽  
Kantima Chaochanchaikul

The sound absorbing efficiency of natural rubber (NR) foam is affected by the cell morphology of foam. Potassium oleate (K-oleate) and sodium bicarbonate (NaHCO3) were used as blowing agents to create open-cell foam. Amounts of the blowing agent were varied from 0.5 to 8.0 part per hundred of rubber (phr) to evaluate cell size and number of foam cell as well as sound adsorption coefficient of NR foam. The NR foam specimens were prepared using mould and air-circulating oven for vulcanizing and foaming processes. The results indicated that K-oleate at 2.0 phr and NaHCO3 at 0.5 phr led to form NR foam with the smallest cell size and the largest number of foam cell. At low frequencies, the optimum sound adsorption coefficient of NR foam was caused by filling K-oleate 2 phr. However, that of NR foam at high frequencies was provided by 0.5 phr-NaHCO3 addition.


1993 ◽  
Vol 107 (3) ◽  
pp. 179-182 ◽  
Author(s):  
J. R. Cullen ◽  
M. J. Cinnamond

The relationship between diabetes and senbsorineural hearing loss has been disputed. This study compares 44 insulin-dependent diabetics with 38 age and sex matched controls. All had pure tone and speech audiometry performed, with any diabetics showing sensorineural deafness undergoing stapedial reflecx decat tests. In 14 diabetics stapedial reflex tests showed no tone decay in any patient, but seven showed evidence of recruitment. Analysis of vaiance showed the diabetics to be significantly deafer than the control population.The hearing loss affected high frequencies in both sexes, but also low frequencies in the male. Speech discrimination scores showed no differences. Further analysis by sex showed the males to account for most of the differences. Analysys of the audiograms showered mostly a high tone loss. Finally duration of disbetes, insulin dosage and family history of diabtes were not found to have a significant effect on threshold.


2022 ◽  
pp. 1-29
Author(s):  
Andrew R. Wagner ◽  
Megan J. Kobel ◽  
Daniel M. Merfeld

Abstract In an effort to characterize the factors influencing the perception of self-motion rotational cues, vestibular self-motion perceptual thresholds were measured in 14 subjects for rotations in the roll and pitch planes, as well as in the planes aligned with the anatomic orientation of the vertical semicircular canals (i.e., left anterior, right posterior; LARP, and right anterior, left posterior; RALP). To determine the multisensory influence of concurrent otolith cues, within each plane of motion, thresholds were measured at four discrete frequencies for rotations about earth-horizontal (i.e., tilts; EH) and earth-vertical axes (i.e., head positioned in the plane of the rotation; EV). We found that the perception of rotations, stimulating primarily the vertical canals, was consistent with the behavior of a high-pass filter for all planes of motion, with velocity thresholds increasing at lower frequencies of rotation. In contrast, tilt (i.e, EH rotation) velocity thresholds, stimulating both the canals and otoliths (i.e., multisensory integration), decreased at lower frequencies and were significantly lower than earth-vertical rotation thresholds at each frequency below 2 Hz. These data suggest that multisensory integration of otolithic gravity cues with semicircular canal rotation cues enhances perceptual precision for tilt motions at frequencies below 2 Hz. We also showed that rotation thresholds, at least partially, were dependent on the orientation of the rotation plane relative to the anatomical alignment of the vertical canals. Collectively these data provide the first comprehensive report of how frequency and axis of rotation influence perception of rotational self-motion cues stimulating the vertical canals.


Author(s):  
Jerome E. Manning

Abstract Statistical energy analysis provides a technique to predict acoustic and vibration levels in complex dynamic systems. The technique is most useful for broad-band excitation at high frequencies where many modes contribute to the response in any given frequency band. At mid and low frequencies, the number of modes contributing to the response may be quite small. In this case SEA predictions show large variability from measured data and may not be useful for vibroacoustic design. This paper focuses on the use of measured data to improve the accuracy of the predictions. Past work to measure the SEA coupling and damping loss factors has not been successful for a broad range of systems that do not have light coupling. This paper introduces a new hybrid SEA technique that combines measured mobility functions with analytical SEA predictions. The accuracy of the hybrid technique is shown to be greatly improved at mid and low frequencies.


2004 ◽  
Vol 14 (5) ◽  
pp. 375-385 ◽  
Author(s):  
E.L. Groen ◽  
W. Bles

We examined to what extent body tilt may augment the perception of visually simulated linear self acceleration. Fourteen subjects judged visual motion profiles of fore-aft motion at four different frequencies between 0.04âĂŞ0.33 Hz, and at three different acceleration amplitudes (0.44, 0.88 and 1.76 m / s 2 ). Simultaneously, subjects were tilted backward and forward about their pitch axis. The amplitude of pitch tilt was systematically varied. Using a two-alternative-forced-choice paradigm, psychometric curves were calculated in order to determine: 1) the minimum tilt amplitude required to generate a linear self-motion percept in more than 50% of the cases, and 2) the maximum tilt amplitude at which rotation remains sub-threshold in more than 50% of the cases. The results showed that the simulation of linear self motion became more realistic with the application of whole body tilt, as long as the tilt rate remained under the detection threshold of about 3 deg/s. This value is in close agreement with the empirical rate limit commonly used in flight simulation. The minimum required motion cue was inversely proportional to stimulus frequency, and increased with the amplitude of the visual displacement (rather than acceleration). As a consequence, the range of useful tilt stimuli became more critical with increasing stimulus frequency. We conclude that this psychophysical approach reveals valid parameters for motion driving algorithms used in motion base simulators.


2003 ◽  
Vol 89 (1) ◽  
pp. 390-400 ◽  
Author(s):  
L. H. Zupan ◽  
D. M. Merfeld

Sensory systems often provide ambiguous information. For example, otolith organs measure gravito-inertial force (GIF), the sum of gravitational force and inertial force due to linear acceleration. However, according to Einstein's equivalence principle, a change in gravitational force due to tilt is indistinguishable from a change in inertial force due to translation. Therefore the central nervous system (CNS) must use other sensory cues to distinguish tilt from translation. For example, the CNS might use dynamic visual cues indicating rotation to help determine the orientation of gravity (tilt). This, in turn, might influence the neural processes that estimate linear acceleration, since the CNS might estimate gravity and linear acceleration such that the difference between these estimates matches the measured GIF. Depending on specific sensory information inflow, inaccurate estimates of gravity and linear acceleration can occur. Specifically, we predict that illusory tilt caused by roll optokinetic cues should lead to a horizontal vestibuloocular reflex compensatory for an interaural estimate of linear acceleration, even in the absence of actual linear acceleration. To investigate these predictions, we measured eye movements binocularly using infrared video methods in 17 subjects during and after optokinetic stimulation about the subject's nasooccipital (roll) axis (60°/s, clockwise or counterclockwise). The optokinetic stimulation was applied for 60 s followed by 30 s in darkness. We simultaneously measured subjective roll tilt using a somatosensory bar. Each subject was tested in three different orientations: upright, pitched forward 10°, and pitched backward 10°. Five subjects reported significant subjective roll tilt (>10°) in directions consistent with the direction of the optokinetic stimulation. In addition to torsional optokinetic nystagmus and afternystagmus, we measured a horizontal nystagmus to the right during and following clockwise (CW) stimulation and to the left during and following counterclockwise (CCW) stimulation. These measurements match predictions that subjective tilt in the absence of real tilt should induce a nonzero estimate of interaural linear acceleration and, therefore, a horizontal eye response. Furthermore, as predicted, the horizontal response in the dark was larger for Tilters ( n = 5) than for Non-Tilters ( n= 12).


Author(s):  
Gundula B. Runge ◽  
Al Ferri ◽  
Bonnie Ferri

This paper considers an anytime strategy to implement controllers that react to changing computational resources. The anytime controllers developed in this paper are suitable for cases when the time scale of switching is in the order of the task execution time, that is, on the time scale found commonly with sporadically missed deadlines. This paper extends the prior work by developing frequency-weighted anytime controllers. The selection of the weighting function is driven by the expectation of the situations that would require anytime operation. For example, if the anytime operation is due to occasional and isolated missed deadlines, then the weighting on high frequencies should be larger than that for low frequencies. Low frequency components will have a smaller change over one sample time, so failing to update these components for one sample period will have less effect than with the high frequency components. An example will be included that applies the anytime control strategy to a model of a DC motor with deadzone and saturation nonlinearities.


2001 ◽  
Vol 86 (2) ◽  
pp. 692-702 ◽  
Author(s):  
Michaël B. Zugaro ◽  
Eiichi Tabuchi ◽  
Céline Fouquier ◽  
Alain Berthoz ◽  
Sidney I. Wiener

Head direction (HD) cells discharge selectively in macaques, rats, and mice when they orient their head in a specific (“preferred”) direction. Preferred directions are influenced by visual cues as well as idiothetic self-motion cues derived from vestibular, proprioceptive, motor efferent copy, and command signals. To distinguish the relative importance of active locomotor signals, we compared HD cell response properties in 49 anterodorsal thalamic HD cells of six male Long-Evans rats during active displacements in a foraging task as well as during passive rotations. Since thalamic HD cells typically stop firing if the animals are tightly restrained, the rats were trained to remain immobile while drinking water distributed at intervals from a small reservoir at the center of a rotatable platform. The platform was rotated in a clockwise/counterclockwise oscillation to record directional responses in the stationary animals while the surrounding environmental cues remained stable. The peak rate of directional firing decreased by 27% on average during passive rotations ( r 2 = 0.73, P< 0.001). Individual cells recorded in sequential sessions ( n = 8) reliably showed comparable reductions in peak firing, but simultaneously recorded cells did not necessarily produce identical responses. All of the HD cells maintained the same preferred directions during passive rotations. These results are consistent with the hypothesis that the level of locomotor activity provides a state-dependent modulation of the response magnitude of AD HD cells. This could result from diffusely projecting neuromodulatory systems associated with motor state.


Sign in / Sign up

Export Citation Format

Share Document