scholarly journals Simple Spectrophotometric Method for Determination of Paroxetine in Tablets Using 1,2-Naphthoquinone-4-Sulphonate as a Chromogenic Reagent

2009 ◽  
Vol 2009 ◽  
pp. 1-8 ◽  
Author(s):  
Ibrahim A. Darwish ◽  
Heba H. Abdine ◽  
Sawsan M. Amer ◽  
Lama I. Al-Rayes

Simple and rapid spectrophotometric method has been developed and validated for the determination of paroxetine (PRX) in tablets. The proposed method was based on nucleophilic substitution reaction of PRX with 1,2-naphthoquinone-4-sulphonate (NQS) in an alkaline medium to form an orange-colored product of maximum absorption peak () at 488 nm. The stoichiometry and kinetics of the reaction were studied, and the reaction mechanism was postulated. Under the optimized reaction conditions, Beer's law correlating the absorbance (A) with PRX concentration (C) was obeyed in the range of 1–8 g . The regression equation for the calibration data was: A = 0.0031 + 0.1609 C, with good correlation coefficients (0.9992). The molar absorptivity () was L  1 . The limits of detection and quantitation were 0.3 and 0.8 g , respectively. The precision of the method was satisfactory; the values of relative standard deviations did not exceed 2%. The proposed method was successfully applied to the determination of PRX in its pharmaceutical tablets with good accuracy and precisions; the label claim percentage was %. The results obtained by the proposed method were comparable with those obtained by the official method.

2013 ◽  
Vol 10 (3) ◽  
pp. 965-970
Author(s):  
Baghdad Science Journal

A simple, rapid and sensitive spectrophotometric method has been developed for the determination of captopril in aqueous solution. The method is based on reaction of captopril with 2,3-dichloro 1,4- naphthoquinon(Dichlone) in neutral medium to form a stable yellow colored product which shows maximum absorption at 347 nm with molar absorptivity of 5.6 ×103 L.mole-1. cm-1. The proposed method is applied successfully for determination of captopril in commercial pharmaceutical tablets.


2008 ◽  
Vol 5 (1) ◽  
pp. 93-99 ◽  
Author(s):  
M. S. Suresha ◽  
Mansour S. Abdul Galil ◽  
Mahadevaiah ◽  
M. A. Sathish ◽  
M. S. Yogendra Kumar ◽  
...  

A simple, sensitive and economical spectrophotometric method for the determination of hydrogen sulphide is developed. The method is based on a redox reaction in that Mn(III) generated electrolytically is taken in excess, which is oxidizing a known but a less quantity of hydrogen sulphide and the unreacted oxidant will oxidize furthero-tolidine to produce an orange yellow quinonediimine absorbing cation (λ max. 455 nm). Therefore, in principle, the decrease in color intensity of the absorbing system is proportional to the concentration of hydrogen sulphide. The stoichiometry between Mn(III) ando-tolidine and stability constant of the complex were determined by Job's continuous method, the corresponding values were found to be 2:1 and 1.42X105Lmol-1. The system was obeying Lambert-Beer's law in the range 0.2-1.4 μg mL-1of hydrogen sulphide. Molar absorptivity, correlation coefficient and Sandell's sensitivity values were also calculated and found to be 4.2062X103L mol-1cm-1, 0.999 and 0.0012 μg cm-2respectively. The method was employed for the determination of hydrogen sulphide in water samples. The results obtained were reproducible with acceptable standard deviation 0.01-0.068 and relative standard deviation, less than 3.21%. For a comparison, hydrogen sulphide present in water samples were also determined separately following the methylene blue official method. The results of the proposed method compare well with the official method.


Author(s):  
RUAA MUAYAD MAHMOOD ◽  
HAMSA MUNAM YASSEN ◽  
SAMAR , NAJWA ISSAC ABDULLA AHMED DARWEESH ◽  
NAJWA ISSAC ABDULLA

Simple, rapid and sensitive extractive spectrophotometric method is presented for the determination of glibenclamide (Glb) based on the formation of ion-pair complex between the Glb and anionic dye, methyl orange (MO) at pH 4. The yellow colored complex formed was quantitatively extracted into dichloromethane and measured at 426 nm. The colored product obeyed Beer’s law in the concentration range of (0.5-40) μg.ml-1. The value of molar absorptivity obtained from Beer’s data was found to be 31122 L.mol-1.cm-1, Sandell’s sensitivity value was calculated to be 0.0159 μg.cm-2, while the limits of detection (LOD) and quantification (LOQ) were found to be 0.1086 and 0.3292 μg.ml-1, respectively. The stoichiometry of the complex created between the Glb and MO was 1:1 as determined via Job’s method of continuous variation and mole ratio method. The method was successfully applied for the analysis of pharmaceutical formulation.


2013 ◽  
Vol 6 (1) ◽  
pp. 133-141 ◽  
Author(s):  
S. Binte Amir ◽  
M. A. Hossain ◽  
M. A. Mazid

The present study was undertaken to develop and validate a simple, sensitive, accurate, precise and reproducible UV spectrophotometric method for cefuroxime axetil using methanol as solvent. In this method the simple UV spectrum of cefuroxime axetil in methanol was obtained which exhibits absorption maxima (?max) at 278 nm. The quantitative determination of the drug was carried out at 278 nm and Beer’s law was obeyed in the range of (0.80-3.60) µg/ml. The proposed method was applied to pharmaceutical formulation and percent amount of drug estimated (95.6% and 96%) was found in good agreement with the label claim. The developed method was successfully validated with respect to linearity, specificity, accuracy and precision. The method was shown linear in the mentioned concentrations having line equation y = 0.05x + 0.048 with correlation coefficient of 0.995. The recovery values for cefuroxime axetil ranged from 99.85-100.05. The relative standard deviation of six replicates of assay was less than 2%. The percent relative standard deviations of inter-day precision ranged between 1.45-1.92% and intra-day precision of cefuroxime axetil was 0.96-1.51%. Hence, proposed method was precise, accurate and cost effective.  Keywords: UV-Vis spectrophotometer; Method validation; Cefuroxime axetil; Recovery studies.  © 2013 JSR Publications. ISSN: 2070-0237 (Print); 2070-0245 (Online). All rights reserved.   doi: http://dx.doi.org/10.3329/jsr.v6i1.14879 J. Sci. Res. 6 (1), 133-141 (2013)  


2008 ◽  
Vol 27 (2) ◽  
pp. 149 ◽  
Author(s):  
Ivana Savić ◽  
Goran Nikolić ◽  
Vladimir Banković

Simple, accurate and reproducible UV-spectrophotometric method was developed and validated for the estimation of phenylephrine hydrochloride in pharmaceutical nasal drops formulations. Phenylephrine hydrochloride was estimated at 291 nm in 1 mol⋅dm-3 sodium hydroxide (pH 13.5). Beer’s law was obeyed in the concentration range of 10–100 μg⋅cm−3 (r2 = 0.9990) in the sodium hydroxide medium. The apparent molar absorptivity was found to be 1.63×103 dm3⋅mol−1⋅cm−1. The method was tested and validated for various parameters according to the ICH (International Conference on Harmonization) guidelines. The detection and quantitation limits were found to be 0.892 and 2.969 μg⋅cm−3, respectively. The proposed method was successfully applied for the determination of phenylephrine hydrochloride in pharmaceutical nasal drops formulations. The results demonstrated that the procedure is accurate, precise and reproducible (relative standard deviation < 1 %), while being simple, cheap and less time consuming, and hence can be suitably applied for the estimation of phenylephrine hydrochloride in different dosage forms.


2008 ◽  
Vol 3 ◽  
pp. ACI.S1053 ◽  
Author(s):  
Ibrahim A. Darwish ◽  
Sawsan M. Amer ◽  
Heba H. Abdine ◽  
Lama I. Al-Rayes

New simple spectrofluorimetric method with enhanced sensitivity has been developed and validated for the determination of the antidepressant paroxetine (PXT) in its dosage forms and plasma. The method was based on nucleophilic substitution reaction of PXT with 4-chloro-7-nitrobenzo-2-oxa-1,3-diazole in an alkaline medium (pH 8) to form a highly fluorescent derivative that was measured at 545 nm after excitation at 490 nm. The factors affecting the reaction was carefully studied and optimized. The kinetics of the reaction was investigated, and the reaction mechanism was presented. Under the optimized conditions, linear relationship with good correlation coefficient (0.9993) was found between the fluorescence intensity and PXT concentration in the range of 80-800 ng ml-1. The limits of detection and quantitation for the method were 25 and 77 ng ml-1, respectively. The precision of the method was satisfactory; the values of relative standard deviations did not exceed 3%. The proposed method was successfully applied to the determination of PXT in its pharmaceutical tablets with good accuracy; the recovery values were 100.2 ± 1.61%. The results obtained by the proposed method were comparable with those obtained by the official method. The proposed method is superior to the previously reported spectrofluorimetric method for determination of PXT in terms of its higher sensitivity and wider linear range. The high sensitivity of the method allowed its successful application to the analysis of PXT in spiked human plasma. The proposed method is practical and valuable for its routine application in quality control and clinical laboratories for analysis of PXT.


1997 ◽  
Vol 80 (2) ◽  
pp. 388-391 ◽  
Author(s):  
Ritu Kesari ◽  
Manish Rai ◽  
Vinay Kumar Gupta

Abstract A sensitive spectrophotometric method was developed for determination of paraquat, a widely used herbicide. Paraquat was reduced with glucose in an alkaline medium, and the blue radical ion obtained was measured at 600 nm. Beer’s law was obeyed at 0.1–1.2 ppm paraquat. The molar absorptivity was 1.26 × 105 L mol-1 cm-1. The standard deviation and relative standard deviation were ± 0.007 and 2.0%, respectively, for 5 μg paraquat/10 mL analyzed over 7 days. The method was free from interference by other commonly used pesticides and metal ions. The method may be used to the determine paraquat in plants, fruits, grains, water, blood, and urine.


2011 ◽  
Vol 8 (4) ◽  
pp. 1528-1535 ◽  
Author(s):  
F. Nekouei ◽  
Sh. Nekouei

A simple, fast, reproducible and sensitive method for the flotation- spectrophotometric determination of Al3+is reported. The apparent molar absorptivity (ε) of the ion associate was determined to be 8.35×104L mol-1cm-1. The calibration curve was linear in the concentration range of 1.0-50 ng mL-1of Al3+with a correlation coefficient of 0.9997. The limit of detection (LOD) was 0.621 ng mL. The relative standard deviation (RSD) at 10 and 30 ng mL-1of aluminium were 1.580 and 2.410% (n=7) respectively. The method was applied for measuring the amount of aluminium in water samples.


2007 ◽  
Vol 4 (4) ◽  
pp. 467-473 ◽  
Author(s):  
Mahadevaiah ◽  
M. S. Yogendra Kumar ◽  
Mansour S. Abdul Galil ◽  
M. S. Suresha ◽  
M. A. Sathish ◽  
...  

A simple spectrophotometric method is developed for the determination of phosphate in sugar cane juice, water and detergent samples. The method is based on the formation of phosphomolybdate with added molybdate followed by its reduction with sodium sulphide in aqueous sulfuric acid medium. The system obeys Lambert-Beer’s law at 715 nm in the concentration range 0.3-12.24 ppm. Molar absorptivity, correlation coefficient and Sandell’s sensitivity values were found to be 6.1x103mol-1cm-1, 0.999 and 0.0156 µg cm-2respectively. The results obtained were reproducible with acceptable standard deviation 3.7% and relative error 3.4%. For a comparison of the method phosphate present in various samples were also determined separately following an official method. The results of the developed method compare well with those of the official method.


2019 ◽  
Vol 53 (4) ◽  
Author(s):  
Padmarajaiah Nagaraja ◽  
Naef Ghllab Saeed Al-Tayar ◽  
Anantharaman Shivakumar ◽  
Ashwinee Kumar Shresta ◽  
Avinash K. Gowda

A very simple, sensitive and fairly selective direct spectrophotometric method is presented for the rapid determination of thallium(III) at trace level. The method is based on the oxidation of 2-hydrazono-3-methyl-2,3-dihydrobenzo[d]thiazole hydrochloride (MBTH) by thallium(III) in phosphoric acid medium to form a diazoniumcation, which couples immediately with 10,11-dihydro-5Hdibenzo[b,f]azepine (IDB) at room temperature giving a blue colored species having a maximum absorption at 660 nm. The reaction conditions and other important analytical parameters were optimized.The calibration curve was found to be linear over the range of 0.1-4 μg/mL with molar absorptivity of 4.5 × 104 L mol- cm-1 and Sandell’s sensitivity of 0.00454 μg cm-2. The relative standard deviation and limit of detection have been found to be 0.58% and 0.0147 μg/mL respectively. Almost all common anions and cations are found notto interfering in matrix level of the analytical process. The method has been successfully applied for the determination of thallium(III) in synthetic standard mixtures, water and human urine samples. The performance of proposed method was evaluated in terms of student’s t-test and variance ratio F-test, to find out the significance of proposed method over the reported methods.    


Sign in / Sign up

Export Citation Format

Share Document