scholarly journals The Influence of Recycling on the Properties of Interface between Ceramic and Dental Alloys

2020 ◽  
Vol 2020 ◽  
pp. 1-9
Author(s):  
Yinghui Wang ◽  
Honglan Huang ◽  
Honglei Lin ◽  
Lei Jiang ◽  
Yu Pan ◽  
...  

Statement of Problem. Results are discrepant regarding the metal-ceramic interface of dental alloys affected by recycling. Purpose. The purpose of this study was to evaluate the effect of recycling on the properties of interface between 2 dental alloys and their corresponding porcelains. Materials and Methods. Noble alloy (Pd-Cu-Ga) and high-noble alloy (Au-Pt) were used in this study. Metal matrices (cylinders Φ4 mm×4 mm with pedestal Φ5 mm×1 mm) were prepared by arc melting in argon after recasting 1-3 times. Corresponding porcelain with overall dimensions of Φ4 mm×2 mm was veneered on each metal cylinder. There were 22 specimens in each alloy group. Specifically, two specimens of each group were chosen randomly for interfacial morphology and diffusion analyses by scanning electron microscopy (SEM) equipped with energy-dispersive X-ray spectroscopy (EDS). The remaining 20 specimens were divided into 2 groups with or without thermal cycling. The bond strength was evaluated by shear test, and the data were analyzed by two-way analysis of variance (ANOVA). The failure mode of shear test specimen was observed with a stereoscopic microscopy and subjected to the exact probability test (α=0.05). Results. According to the results from SEM, no obvious difference was observed in the interfacial morphology of both Pd-Cu-Ga and Au-Pt alloys among different recasting specimens. EDS analysis revealed that no significant difference was found in the width of elemental diffusion among 2 test alloys after recycling 1-3 times. Notably, in Pd-Cu-Ga alloy groups, the peak of Ga in thrice recasting was lower than those in first and second recastings. And there was no significant difference (P>0.05) in the metal-ceramic shear bond strength of Pd-Cu-Ga and Au-Pt alloys after recycling 1-3 times, with or without thermal cycling. The results of failure modes observed on specimens were not affected by the recycling and thermal cycling in the 2 tested alloys. Conclusions. Within the limitations of this study, the Pd-Cu-Ga and Au-Pt alloys can be recycled 2 times without significant changes on the properties of metal-ceramic interface, with or without thermal cycling.

2016 ◽  
Vol 17 (11) ◽  
pp. 920-925 ◽  
Author(s):  
Bandar MA Al-Makramani ◽  
Fuad A Al-Sanabani ◽  
Abdul AA Razak ◽  
Mohamed I Abu-Hassan ◽  
Ibrahim Z AL-Shami ◽  
...  

ABSTRACT Aim The aim of this study was to evaluate the effect of surface treatments on shear bond strength (SBS) of Turkom-Cera (Turkom-Ceramic (M) Sdn. Bhd., Puchong, Malaysia) all-ceramic material cemented with resin cement Panavia-F (Kuraray Medical Inc., Okayama, Japan). Materials and methods Forty Turkom-Cera ceramic disks (10 mm × 3 mm) were prepared and randomly divided into four groups. The disks were wet ground to 1000-grit and subjected to four surface treatments: (1) No treatment (Control), (2) sandblasting, (3) silane application, and (4) sandblasting + silane. The four groups of 10 specimens each were bonded with Panavia-F resin cement according to manufacturer's recommendations. The SBS was determined using the universal testing machine (Instron) at 0.5 mm/min crosshead speed. Failure modes were recorded and a qualitative micromorphologic examination of different surface treatments was performed. The data were analyzed using the one-way analysis of variance (ANOVA) and Tukey honestly significant difference (HSD) tests. Results The SBS of the control, sandblasting, silane, and sandblasting + silane groups were: 10.8 ± 1.5, 16.4 ± 3.4, 16.2 ± 2.5, and 19.1 ± 2.4 MPa respectively. According to the Tukey HSD test, only the mean SBS of the control group was significantly different from the other three groups. There was no significant difference between sandblasting, silane, and sandblasting + silane groups. Conclusion In this study, the three surface treatments used improved the bond strength of resin cement to Turkom-Cera disks. Clinical significance The surface treatments used in this study appeared to be suitable methods for the cementation of glass infiltrated all-ceramic restorations. How to cite this article Razak AAA, Abu-Hassan MI, AL-Makramani BMA, AL-Sanabani FA, AL-Shami IZ, Almansour HM. Effect of Surface Treatments on the Bond Strength to Turkom-Cera All-Ceramic Material. J Contemp Dent Pract 2016;17(11):920-925.


Author(s):  
Fubin Song ◽  
S. W. Ricky Lee

The present study is aimed at evaluating the effect of ball shear tool wear and fixture rigidity on ball shear and ball pull tests respectively. In particular, the emphasis is placed on understanding the progressive failure mechanism during the ball shear test. The location of crack initiating is investigated on two kinds of shear tool with different wear features. In this paper, the experimental investigation is presented. Specimens with PBGA solder balls are fabricated and a series of ball shear and pull tests are conducted. In the shear test, the shear tool is stopped at a certain stage during test, and then the specimens are inspected by SEM. The failure modes and location of cracks are characterized. From the ball attachment strength and crack location of the ball shear test, no significant difference is found between the shear tools with different wear features. For investigating the effect of fixture rigidity on the ball pull test, two kinds of PBGA package with different sizes was fixed on the fixtures with and without gluing on a rigid plate. The failure modes and ball pull strength with different fixture rigidity were compared. The test results indicate that more brittle failures are found on the specimens without gluing on the rigid plate during the ball pull test, both on two kinds of package with different sizes. In addition, the data scattering of ball pull strength is large on the case without gluing on rigid plate.


2019 ◽  
Vol 30 (4) ◽  
pp. 350-355 ◽  
Author(s):  
Thiago Lopes de Freitas ◽  
Rafael Pino Vitti ◽  
Milton Edson Miranda ◽  
William Cunha Brandt

Abstract The aim of this study was to evaluate the effect of different glass fiber posts (GFPs) diameters on the push-out bond strength to dentin. Forty unirradicular human teeth were endodontically treated and used for cementation of GFPs (White Post DC, FGM) with different diameters (n=10): P1 - ø 1.6 mm coronal x 0.85 mm apical; P2 - ø 1.8 mm coronal x 1.05 mm apical; P5 - ø 1.4 mm coronal x 0.65 mm apical; and PC - customized post number 0.5 with composite resin (Tetric Ceram A2, Ivoclair Vivadent). All GFPs were cemented into the root canal using a dual-curing luting composite (Variolink II, Ivoclar Vivadent). One slice (1.7 mm) of each root third of cemented GFP (cervical, middle, and apical) was submitted to push-out testing. Failure modes of all specimens were classified as: adhesive failure between resin cement and post; adhesive failure between dentin and resin cement; cohesive failure within resin cement, post or dentin; and mixed failure. The data were analyzed with two-way ANOVA and Tukey’s test (a=0.05). The highest bond strength values were presented for the P2 and PC groups. There was no statistically significant difference between the GFP thirds in each group. The groups P2, P5, and PC showed predominantly adhesive failure. For P1, the most prevalent type of failure was adhesive between resin cement and post. It may be concluded that a glass fiber post that is well adapted to the root canal presents higher bond strength values, regardless of GFP third.


2012 ◽  
Vol 23 (5) ◽  
pp. 521-526 ◽  
Author(s):  
Renata Baldissera ◽  
Ricardo Abreu da Rosa ◽  
Márcia Helena Wagner ◽  
Milton Carlos Kuga ◽  
Fabiana Soares Grecca ◽  
...  

The aim of this study was to evaluate the effects of different irrigants on sealer-dentin bond strength when using Real Seal. Thirty single-rooted teeth were divided into 3 groups. In one group, the teeth were irrigated with 3 mL of 2.5% NaOCl after each file change, flushed with 17% EDTA for 3 min and finally rinsed with 3 mL of 2.5% NaOCl. In the other two groups, rinse with NaOCl was replaced with 2% chlorhexidine gluconate (CHX) and 0.9% saline, respectively. Each root was sectioned transversally into apical, middle and coronal thirds to obtain 2-mm-thick slices. Each slice was filled with Real Seal and Resilon. Push-out test was used to analyze bond strength and failure modes were classified as adhesive, cohesive or mixed, according to SEM observations. The push-out test did not reveal any statistically significant difference (p>0.05) between the irrigants. However, the groups exhibited significantly different (p<0.05) bond strengths in terms of the root canal third. Higher bond strength was observed at the apical third when compared with coronal third, while middle third presented intermediary values. Fifteen specimens were analyzed by SEM (5 per group). Eleven specimens exhibited adhesive failures (5 in saline, 4 in NaOCl and 2 in CHX group); 2 cohesive failures were observed in the CHX group, and 1 mixed failure each was observed in the CHX and NaOCl groups. The tested irrigants did not influence the bond strength of Resilon and Real Seal to dentin. The apical third exhibited higher mean bond strengths and adhesive failures were predominant.


Author(s):  
Tugba Serin Kalay ◽  
Yakup Kara ◽  
Sengul alpay Karaoglu ◽  
Sevgi Kolaylı

Background: Antimicrobial agents are recommended for disinfection of the cavity following mechanical dental caries removal prior to application of restorative material. There is limited information about stabilized chlorine dioxide (ClO2) as a cavity disinfectant. Objective: The objective of this study is to determine the antimicrobial activity and effect on dentin bond strength of ClO2 compared to chlorhexidine digluconate (CHX), sodium hypochlorite (NaOCl) and ethanolic propolis extract (EPE). Methods: Antimicrobial activities of agents against oral pathogens (Staphylococcus aureus, Enterococcus faecalis, Streptococcus mutans, Lactobacillus acidophilus, Lactobacillus casei, Candida albicans, and Saccharomyces cerevisiae) and analyses of EPE were examined. Seventy-five mandibular third molars were sectioned, prepared and divided into five subgroups (n=15/group). Cavity disinfectants (2% CHX, 2.5% NaOCl, 30% EPE, 0.3% ClO2) were applied to etched dentin prior to adhesive and composite build-up. Shear bond strength (SBS) was evaluated with a universal testing machine at a crosshead speed of 0.5 mm/min. The SBS data were analyzed with one-way analysis of variance (ANOVA) and Tukey’s post-hoc test (p <0.05). The failure modes were evaluated with a stereomicroscope. Results: It was determined that the compared disinfectants were showed different inhibition zone values against oral pathogens. ClO2 exhibited the highest antimicrobial activity, followed by CHX, NaOCI and EPE, respectively. No statistically significant difference was observed in the SBS values between the disinfectant treated groups and control group. The failure modes were predominantly mixed. Conclusion: The use of 0.3% stabilized ClO2 as a cavity disinfectant agent exhibited high antimicrobial activity against oral pathogens and no adverse effects on SBS to etched dentin.


2009 ◽  
Vol 79 (5) ◽  
pp. 945-950 ◽  
Author(s):  
Ding Xiaojun ◽  
Lu Jing ◽  
Guo Xuehua ◽  
Ruan Hong ◽  
Yu Youcheng ◽  
...  

Abstract Objective: To evaluate the effect of casein phosphopeptide–amorphous calcium phosphate (CPP-ACP) paste on shear bond strength and debonding failure modes of orthodontic brackets. Materials and Methods: Freshly extracted premolars were randomly divided into four groups (n =18) as follows: in groups 1 and 3, the enamel was treated with a solution of CPP-ACP dissolved in artificial saliva; groups 2 and 4 served as controls, and the enamel was treated with artificial saliva. After conventional acid etching, in groups 1 and 2, brackets were bonded using a light-cured bonding system (Blugloo); while in groups 3 and 4, brackets were bonded using a conventional bonding system (Unite Bonding Adhesive). Bonded specimens were subjected to thermal cycling for 1000 cycles before debonding procedures. After debonding, teeth and brackets were examined under a stereomicroscope at 10× magnification to determine whether any adhesive remained, in accordance with the adhesive remnant index. The acid-etched enamel surfaces were also observed using scanning electron microscopy after treatment with and without CPP-ACP paste. Results: The shear bond strengths of group 1 were significantly higher than those seen in group 2 (P &lt; .01). There was no significant difference in the shear bond strengths of groups 3 and 4 (P &gt; .05). Scanning electron microscopic observation showed that the pretreated enamel surface was rougher than that of the control surface after acid etching. Conclusion: The use of CPP-ACP can be considered as an alternative prophylactic application in orthodontic practice since it did not compromise bracket bond strength.


2004 ◽  
Vol 12 (4) ◽  
pp. 280-284 ◽  
Author(s):  
Mariana Pretti ◽  
Edson Hilgert ◽  
Marco Antônio Bottino ◽  
Rander Pereira Avelar

INTRODUCTION: Based on the importance of the integrity of the metal/ceramic interface, the purpose of this work was to evaluate the shear bond strength of the metal-ceramic union of two Co-Cr alloys (Wirobond C, Bego; Remanium 2000, Dentaurum) combined with Omega 900 ceramic (Vita Zahnfabrik). MATERIAL AND METHOD: Eleven cylindrical matrixes were made for each alloy, and the metallic portion was obtained with the lost wax casting technique with standardized waxing of 4mm of height and of 4mm of diameter. The ceramic was applied according to the manufacturer's recommendations with the aid of a teflon matrix that allowed its dimension to be standardized in the same size as the metallic portion. The specimens were submitted to the shear bond test in an universal testing machine (EMIC), with the aid of a device developed for such intention, and constant speed of 0.5mm/min. RESULTS AND CONCLUSIONS: The mean resistance was 48.387MPa for Wirobond C alloy, with standard deviation of 17.718, and 55.956MPa for Remanium 2000, with standard deviation of 17.198. No statistically significant difference was observed between the shear strength of the two metal-ceramic alloys.


2017 ◽  
Vol 42 (3) ◽  
pp. 335-341 ◽  
Author(s):  
AE Llerena-Icochea ◽  
RM Costa ◽  
AFS Borges ◽  
JFS Bombonatti ◽  
AY Furuse

SUMMARY Objective: The objective of this study was to evaluate the influence of adhesives with different 10-MDP concentrations on the shear bond strength of a resin cement to zirconia. Methods and Materials: Six experimental adhesives were prepared with the following composition: camphorquinone, 1,2-diaminobenzene, butylhydroxytoluene, diphenyliodonium hexafluorophosphate, 2-hydroxyethyl methacrylate triethylene glycol dimethacrylate, ethoxylated bisphenol A glycol dimethacrylate, urethane dimethacrylate, bisphenol A diglycidyl methacrylate, and ethanol. The 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) monomer was added at 0wt%, 3wt%, 6wt%, 9wt%, 12wt%, or 15wt%. Three commercially available adhesives were evaluated: Single Bond Universal, Single Bond 2, and Signum Zirconia Bond. Resin cement cylinders made with RelyX Ultimate were bonded to yttria-stabilized tetragonal zirconia polycrystal with one of the evaluated adhesives and were subjected to the shear bond strength evaluation. Failure modes were analyzed with a stereoscopic loupe. Statistical analyses were performed with one-way analysis of variance and the Tukey's Honestly Significant Difference test (α=0.05). Pearson's was used to correlate the percentage of 10-MDP in the experimental adhesives and shear bond strength. Results: There were significant differences between adhesives (p&lt;0.00001). The highest shear bond strength values were obtained with the Signum Zirconia Bond and Single Bond Universal. Single Bond 2 showed the lowest values. There were no differences between experimental adhesives. All groups showed adhesives failures. A nonlinear correlation was found between bond strength and percentage of 10-MDP in experimental adhesives (r=0.872). Conclusions: The commercially available adhesives indicated for bonding to zirconia showed the highest bonding values.


Author(s):  
Omnia M. Sami ◽  
Essam A. Naguib ◽  
Rasha H. Afifi ◽  
Shaymaa M. Nagi

Abstract Objective Bonding to different dentin substrates influences resin composite restoration outcomes. This study investigated the influence of different adhesion protocols on the shear bond strength of universal adhesive systems to sound and artificial caries-affected dentin (CAD). Materials and Methods Occlusal enamel of 80 premolars were wet grinded to obtain flat midcoronal dentin. Specimens were equally divided according to the substrate condition: sound and CAD by subjecting to pH-cycling for 14 days. Each dentin substrate was bonded with the adhesive systems used in this study: Single Bond universal adhesive or Prime&Bond universal (applied either in etch-and-rinse or self-etch adhesion protocol). Adhesive systems were utilized according to manufacturers’ instructions, then resin composite was built up. Specimens were tested for shear bond strength. The data were analyzed by three-way analysis of variance, and failure modes were determined using stereomicroscope. Results There was no statistically significant difference between the two tested adhesive systems on artificially created CAD with different adhesion protocols. On sound dentin, Single Bond universal, either in the etch-and-rinse or self-etch adhesion protocols, revealed higher statistically significant shear bond strength mean values compared with CAD. Conclusion Single Bond universal adhesive in an etch-and-rinse adhesion protocol improved only bonding to sound dentin, while no added positive effect for the etching step with Prime&Bond universal adhesive was found when bonded to both sound and CAD substrates. The influence of CAD on the performance of the universal adhesives was material-dependent.


2013 ◽  
Vol 24 (1) ◽  
pp. 40-46 ◽  
Author(s):  
Mônica Barbosa Leal ◽  
Valéria Oliveira Pagnano ◽  
Osvaldo Luiz Bezzon

This study evaluated the casting accuracy of crown margins and metal-ceramic shear bond strength (SBS) of pure titanium injected into casting molds made using 2 investment types at 3 mold temperatures. Sixty crown (30-degree beveled finish line) and 60 cylinder (5 mm diameter × 8 mm high) patterns were divided into 6 groups (n=10), and cast using a phosphate-bonded investment (P) and a magnesium oxide-bonded investment (U), at 400°C (groups P400 and U400), 550°C (groups P550 and U550) and 700°C (groups P700 and U700) mold temperatures. Crown margins were recorded in impression material, the degree of marginal rounding was measured and margin length deficiencies (µm) were calculated. Titanium-ceramic specimens were prepared using Triceram ceramic (2 mm high) and SBS was tested. Failure modes were assessed by optical microscopy. Data were subjected to two-way ANOVA and Tukey's HSD test (α=0.05). For casting accuracy, expressed by marginal deficiency (µm), investment U provided more accurate results (64 ± 11) than P (81 ± 23) (p<0.001). The increase in temperature resulted in different effects for the tested investments (p<0.001), as it provided better casting accuracy for U700 (55 ± 7) and worse for P700 (109 ± 18). Casting accuracy at 700°C (82 ± 31) was significantly different from 400°C (69 ± 9) and 550°C (68 ± 9) (p<0.05). For SBS, there was no significant differences among the groups for factors investment (p=0.062) and temperature (p=0.224), or for their interaction (p=0.149). Investment U provided better casting accuracy than investment P. The SBS was similar for all combinations of investments and temperatures.