scholarly journals Evaluation of the shear bond strength of the union between two CoCr-alloys and a dental ceramic

2004 ◽  
Vol 12 (4) ◽  
pp. 280-284 ◽  
Author(s):  
Mariana Pretti ◽  
Edson Hilgert ◽  
Marco Antônio Bottino ◽  
Rander Pereira Avelar

INTRODUCTION: Based on the importance of the integrity of the metal/ceramic interface, the purpose of this work was to evaluate the shear bond strength of the metal-ceramic union of two Co-Cr alloys (Wirobond C, Bego; Remanium 2000, Dentaurum) combined with Omega 900 ceramic (Vita Zahnfabrik). MATERIAL AND METHOD: Eleven cylindrical matrixes were made for each alloy, and the metallic portion was obtained with the lost wax casting technique with standardized waxing of 4mm of height and of 4mm of diameter. The ceramic was applied according to the manufacturer's recommendations with the aid of a teflon matrix that allowed its dimension to be standardized in the same size as the metallic portion. The specimens were submitted to the shear bond test in an universal testing machine (EMIC), with the aid of a device developed for such intention, and constant speed of 0.5mm/min. RESULTS AND CONCLUSIONS: The mean resistance was 48.387MPa for Wirobond C alloy, with standard deviation of 17.718, and 55.956MPa for Remanium 2000, with standard deviation of 17.198. No statistically significant difference was observed between the shear strength of the two metal-ceramic alloys.

2014 ◽  
Vol 17 (3) ◽  
pp. 50
Author(s):  
Celina Wanderley de Abreu ◽  
Gilberto Duarte Filho ◽  
Alberto Noriyuki Kojima ◽  
Renato Morales Jóias ◽  
Alfredo Mikail Melo Mesquita

<p><span style="font-size: medium;">The objective of this study was to evaluate the influence of different speeds using the piston device in the shear bond strength. 48 cylinders of composed resin had been confectioned (Solidex),and were divided randomly in four groups (n=12).</span><span style="font-size: medium;">  </span><span style="font-size: medium;">The specimens were adapted to the device for the</span><span style="font-size: medium;">  </span><span style="font-size: medium;">shear bond strenth test and were taken to an universal testing machine with a load cell of 1000Kg. The test were carried through with four different speeds: group A: 0,5; group B: 1,0; group C: 1,5 and group D: 2,0mm/min. The mean and standard deviations, in Kgf, were: A - 66,31(10,24); B - 64,53 (20,40); C - 75,23 (11,84) and D - 66,62 (13,81). The data were submitted to ANOVA (p=0,13). The results indicated that it did not have statistical significant difference between the groups</span><span style="font-size: medium;">   </span><span style="font-size: medium;">A, B, C and D concluding that the speed in this type of test, with this device, can be varied without modify results.</span></p>


2011 ◽  
Vol 82 (1) ◽  
pp. 158-164 ◽  
Author(s):  
Maria Francesca Sfondrini ◽  
Esmeralda Xheka ◽  
Andrea Scribante ◽  
Paola Gandini ◽  
Giuseppe Sfondrini

Abstract Objective: To test the null hypothesis that there is no significant difference in the shear bond strength (SBS) and Adhesive Remnant Index (ARI) scores of new vs reconditioned self-ligating brackets. Materials and Methods: One hundred and twenty permanent extracted bovine teeth were embedded in resin blocks. Three different new and reconditioned self-ligating orthodontic brackets (Smart Clip [3M Unitek]; Quick [Forestadent]; and Damon3MX [Ormco]) were tested. Scanning electron microphotographs of the different new (groups 1, 3, and 5) and reconditioned (groups 2, 4, and 6) bracket bases were taken before starting the experiments. Brackets were then bonded to the teeth using an orthodontic adhesive and were then tested in shear mode using an Instron Universal Testing Machine. ARI scores were then recorded. Statistical analysis was performed to determine significant differences in SBS and ARI Scores. Results: Smart Clip and Damon3MX reconditioned brackets showed significantly lower SBS than did new ones. On the contrary, Quick reconditioned brackets showed significantly higher SBS than did new ones. No significant differences in ARI scores were found after the reconditioning process for the three different brackets tested. Conclusion: The in-office reconditioning procedure alters the SBS of self-ligating brackets, although SBS values still remain clinically acceptable.


2001 ◽  
Vol 25 (1) ◽  
pp. 57-63 ◽  
Author(s):  
Azza El-Housseiny ◽  
Hana Jamjoum

This study was undertaken to evaluate the effect of caries detector dyes and/or cavity cleanser on composite bonding and etching patterns of enamel and dentin. One hundred and eight non-carious premolars were divided into six groups according to the enamel and dentin pretreatment investigated. The different pretreatment were as follows: Group I: teeth with prophylaxis only, Group II: Sable seek caries detector dye,Groups III: chlorhexidine cavity cleanser,Group IV: the caries detectors dye followed by prophylaxis, Group V: the cavity cleanser followed by the caries detector dye, and Group IV: Snoop caries detector dye. The shear bond strength of composite resin bonded to enamel and dentin was evaluated by the Instron Universal testing machine while, the topographic details of enamel and dentin were examined by the SEM following the different pretreatment and acid etching. Results of the shear bond strength showed no statistically significant difference among the six groups, with no substantial differences in SEM results. It is concluded that using the caries detector dyes and/or chlorhexidine cavity cleanser before acid etching does not significantly affect composite bonding to enamel and dentin.


2021 ◽  
pp. 030157422110044
Author(s):  
I Ranganayakulu ◽  
D Praveen Kumar Varma ◽  
Padma Priya CV ◽  
RSVM Raghu Ram ◽  
K Anand Viswanadh ◽  
...  

Objectives: To evaluate and compare the effect of adhesion boosters on shear bond strength (SBS) of orthodontic brackets on bleached teeth. Materials and Methods: A sample of 90 extracted maxillary premolars was equally divided into 2 groups of bleached and non-bleached teeth. Twenty-two percent carbamide peroxide gel was used as an agent for bleaching. Each group was further divided equally into 3 subgroups depending on the type of adhesive booster used (Enhance LC, All-bond 2, and no adhesive booster [control]) and maxillary premolars brackets were bonded. Debonding was done with a universal testing machine, and the SBS was recorded. Results: The SBS of non-bleached teeth was highest for All-bond 2 (14.78 ± 2.47 MPa) followed by Enhance LC (13.15 ± 3.49 MPa) and control (10.30 ± 1.06 MPa). The SBS of bleached teeth was highest for All bond 2 (12.23 ± 1.41 MPa) followed by Enhance LC (11.76 ± 1.71 MPa) and control (9.63 ± 1.06 MPa). All subgroups showed a significant difference in SBS (P = .000) on bleached and non-bleached teeth. The SBS showed a significant difference between the bleached and non-bleached teeth in All-bond 2 group (P = .019). Conclusion: Adhesive boosters increased the SBS of both bleached and non-bleached teeth significantly. Among the two adhesive boosters used, All-bond 2 showed more SBS values.


2014 ◽  
Vol 08 (03) ◽  
pp. 348-352 ◽  
Author(s):  
Huseyin Ertas ◽  
Ebru Kucukyilmaz ◽  
Evren Ok ◽  
Banu Uysal

ABSTRACT Objective: This study was aimed to evaluate and to compare the push-out bond strength of different brands of mineral trioxide aggregate (MTA) with a calcium enriched mixture cement (CEM). Materials and Methods: Fifteen extracted, single-rooted human teeth were used. The middle-third of the roots were sliced perpendicular to the long axis into 1.00 ± 0.05 mm thick serial slices (15 root × 4 slice = 60 specimen). The specimens were then divided into three groups (n = 20). The standardized root discs were filled with white CEM, ProRoot MTA, MTA-Angelus and wrapped in a serum-soaked gauze. After 3 days at relative humidity, the push-out bond strengths were measured with a universal testing machine. Data were analyzed using one-way analysis of variance and post hoc Tukey tests. Results: The mean push-out bond strength value of the ProRoot MTA group (12.7 ± 2.5 MPa) was the highest and statistically significant difference was recorded between ProRoot MTA and other groups (P < 0.001). There was no significant difference between the mean bond strength of CEM cement (4.6 ± 1.1 MPa) and MTA-Angelus (4.5 ± 1.5 MPa) (P = 0.982). Conclusion: The push-out bond strength of MTA was changed with the brands and ProRoot MTA had the highest push-out bond strength.


2013 ◽  
Vol 18 (2) ◽  
pp. 76-80 ◽  
Author(s):  
Aisha de Souza Gomes Stumpf ◽  
Carlos Bergmann ◽  
José Renato Prietsch ◽  
Juliane Vicenzi

OBJECTIVE: To determine the shear bond strength of orthodontic brackets using color change adhesives that are supposed to aid in removing excess of bonding material and compare them to a traditional adhesive. METHODS: Ninety metallic and ninety ceramic brackets were bonded to bovine incisors using two color change adhesives and a regular one. A tensile stress was applied by a universal testing machine. The teeth were observed in a microscope after debonding in order to determine the Adhesive Remnant Index (ARI). RESULTS: The statistical analysis (ANOVA, Tukey, and Kruskall-Wallis tests) demonstrated that the mean bond strength presented no difference when metallic and ceramic brackets were compared but the bond resistance values were significantly different for the three adhesives used. The most common ARI outcome was the entire adhesive remaining on the enamel. CONCLUSIONS: The bond strength was similar for metallic and ceramic brackets when the same adhesive system was used. ARI scores demonstrated that bonding with these adhesives is safe even when ceramic brackets were used. On the other hand, bond strength was too low for orthodontic purposes when Ortho Lite Cure was used.


2017 ◽  
Vol 2 (1) ◽  
pp. 35
Author(s):  
Ema Mulyawati

The Effect of desensitizing agent in post-extracoronal bleaching on shear bond strength of composite resin. The dentinal hypersensitivity is a common condition among patients after extracoronal bleaching treatment that usually needs the application of desensitizing agent. The purpose of this study was to evaluate the composite resin restoration shear bond strength with and without desensitizing application after extracoronal bleaching using 40% of H2O2. Twenty one extracted permanent human incisor teeth were randomly divided into 3 groups of 7 each. Group I was with the application of 40% H2O2 without any desensitizing agent. Group II was with the application of 40% of H2O2 with desensitizing agent and group III served as the control. The teeth were immersed in artificial saliva and stored in 37 °C incubator for 7 days. The teeth were restored using composite resin. After restoring the shear bond strength of composite resin was tested using a universal testing machine. Result and conclusion. there is no significant difference between bleaching group with and without desensitizing agent. The application of desensitizing agent after extracoronal bleaching did not impact the composite resin shear bond strength.ABSTRAKDentin hipersensitif merupakan kondisi yang biasa dialami pasien setelah perawatan bleaching ekstrakoronal yang biasanya memerlukan aplikasi bahan desensitasi. Penelitian ini bertujuan untuk mengetahui pengaruh bahan desensitasi pasca bleaching ekstrakoronal menggunakan H2O2 40% terhadap kekutan geser pelekatan restorasi resin komposit. Dua puluh satu gigi permanen insisivus yang telah dicabut dibagi dalam tiga kelompok masing-masing 7 gigi. Kelompok I dilakukan bleaching ekstrakoronal dengan H2O2 tanpa bahan desensitasi. Kelompok II dilakukan bleaching setelah itu diaplikasikan bahan desensitasi dan kelompok III sebagai kelompok kontrol. Semua gigi-gigi tersebut di rendam dalam saliva buatan dan dimasukkan inkubator selama 7 hari pada suhu 37 °C. Selanjutnya seluruh gigi dilakukan restorasi resin komposit menggunakan light cure halogen. Setelah itu dilakukan pengujian kekuatan geser pelekatan menggunakan universal testing machine. Data dianalisis menggunakan uji Kruskal - Wallis. Hasil penelitian menunjukkan bahwa tidak ada perbedaan kekuatan geser pelekatan pada semua kelompok perlakuan (p > 0,05). Dari penelitian ini disimpulkan bahwa tidak terdapat pengaruh aplikasi bahan desensitasi pasca bleaching ekstrakoronal terhadap kekuatan geser pelekatan restorasi resin komposit.


2021 ◽  
Vol 32 (5) ◽  
pp. 96-104
Author(s):  
Ma’an M Nayif ◽  
Masayuki Otsuki ◽  
Junji Tagami

Abstract The aim of this study was to evaluate the micro-shear bond strength (µSBS) of one and two steps self-etch adhesive systems after enamel bleaching with photo-activated bleaching systems of different hydrogen peroxide (HP) concentration. Occlusal enamel of forty intact human molars were flattened and assigned into four groups. GI Unbleached, GII, GIII, and GIV were bleached with Pyrenees (3.5% HP), GC TiON (20% HP), and Hi-Lite (35% HP) respectively. Enamel treatment with one and two steps self-etch adhesives (Clearfil S3 Bond- S3, and Clearfil SE Bond-SE) then micro-tubes were fixed on enamel and filled with AP-X composite (n=5). Bond was tested with the universal testing machine. Data were analyzed using two-way ANOVA and Tukey’s tests at 5 % level of significance. The µSBS was significantly different between adhesives (F=154.46; p<0.05) and bleaching systems (F=77.33; p<0.05) with significant interaction. Specimens bonded with S3 shows a significantly lower μSBS than those bonded with SE (p<0.05) in all groups. For both adhesives the bleached groups demonstrate lower µSBS than unbleached except specimens bleached with Pyrenees and bonded with SE (p>0.05). A significant difference was observed between groups of the bleaching systems (p<0.05). Different peroxide concentrations photo-activated bleaching systems adversely affect μSBS of one and two steps self-etch adhesives. Low concentration system (Pyrenees) does not influence the bond strength of two steps adhesive.


2021 ◽  
Vol 10 (13) ◽  
pp. e34101320132
Author(s):  
Luciana de Vasconcelos Leão ◽  
Adriana Oliveira ◽  
Jefferson Chaves Moreira ◽  
Luiz Renato Paranhos ◽  
Sigmar de Mello Rode ◽  
...  

This research aimed to assess the effect of aluminum oxide sandblasting and discs on the bond strength of metal brackets rebonded on artificially eroded enamel. Fifty-four bovine incisors were divided into groups: Control (Artificial Saliva), AlOx (Aluminum oxide sandblasting), and SL (Aluminum oxide discs). They had their enamel surface flattened with Al2O3 discs and a metallographic polisher, then Knoop microhardness was assessed. AlOx and SL specimens were eroded with Coca-Cola™ for 1 minute, 3 times a day for 7 days. Metal brackets were bonded to the tooth. Shear strength was measured by an EMIC universal testing machine (0.5 mm/min). The Adhesive Remnant Index (ARI) was performed after shearing through magnifying glass (10X). Kolmogorov-Smirnov, Levene, homoscedasticity and ANOVA tests were applied to assess microhardness and shear strength (p=0.163). All groups presented shear bond strength with no significant differences. The ARI showed statistically significant difference between the groups. The prevalence for the control group was ARI 3. However for AlOx and SL, ARI 1 and 2 prevailed. The aluminum oxide sandblasting and aluminum oxide discs did not positively increase the bond strength of brackets when bonded to artificially eroded enamel. The ARI indicated that eroded teeth present higher resin adhesion to enamel.


2009 ◽  
Vol 20 (2) ◽  
pp. 138-142 ◽  
Author(s):  
Valéria Oliveira Pagnano ◽  
Marina de Campos Esquivel ◽  
Mônica Barbosa Leal ◽  
Daniela Nair Borges Felipucci ◽  
Osvaldo Luiz Bezzon

The success of metal-ceramic restorations depends on an optimal bond between metal and ceramic. This study evaluated the effect of 3 casting atmospheres on the metal-ceramic bond strength (MCBS) of 2 Ni-Cr alloys, with beryllium (Fit Cast V) and without beryllium (Fit Cast SB). Sixty acrylic resin patterns (8 mm long and 5 mm diameter) were obtained using a fluorocarbon resin matrix. Wax was used to refine the surface of acrylic resin patterns that were invested and cast in an induction casting machine under normal, vacuum, and argon atmospheres at a temperature of 1340ºC. The castings were divested manually and airborne-particle abraded with 100-µm aluminum-oxide. Ten castings were obtained for each group. The IPS Classic V ceramic was applied (2 mm high and 5 mm diameter). The shear bond strength was tested in a mechanical testing machine with a crosshead speed of 2.0 mm/min. The MCBS data (MPa) were subjected to 2-way analysis of variance (α=0.05). There was no statistically significant difference (p>0.05) between the alloys or among the casting atmospheres. Within the limitations of this study, it may be concluded that the presence of beryllium and the casting atmosphere did not interfere in the MCBS of the evaluated metal-ceramic combinations


Sign in / Sign up

Export Citation Format

Share Document