Pleuraerguss: Vereinfachte Kriterien zur Unterscheidung zwischen Exsudat und Transsudat

2019 ◽  
Vol 7 (6) ◽  
pp. 331-332
Author(s):  
Franz Stanzel

Background: An important part of the investigation of pleural effusion is the identification of markers that help separate exudate from transudate. Objectives: The purposes of this study were to compare the accuracy of published and new sets of criteria to distinguish between exudative and transudative pleural effusions, and to determine whether serum biochemical analysis is necessary. Methods: An externally validated cohort study was performed. Pleural effusions were determined to be transudative or exudative on the basis of an assessment of the medical record by two clinicians blinded to biochemical results. Sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and area under the receiver operating characteristic curve were determined for each proposed combination of criteria. Results: Pleural fluid analysis was available for 311 thoracenteses in the main cohort and for 112 thoracenteses in the validation cohort. The best sensitivity (97% [95% CI 94-99]) and negative likelihood ratio (0.04 [95% CI 0.02-0.08]) for identifying exudative effusions were observed with criteria combining pleural fluid lactate dehydrogenase greater than 0.6 the upper limit of normal serum lactate dehydrogenase and pleural fluid cholesterol greater than 1.04 mmol/L (40 mg/dL). The overall diagnostic accuracy was similar to Light's criteria. Findings were similar in the validation cohort. Conclusions: Our proposed criteria using simultaneously pleural fluid lactate dehydrogenase and pleural fluid cholesterol can identify an exudate with a sensitivity and an overall diagnostic accuracy similar to Light's criteria. It avoids simultaneous blood sampling, thus reducing patient discomfort and potential costs.

2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
Daye Cheng ◽  
Ying Sun ◽  
Hu He

The diagnostic value of serum HE4 in patients with lung cancer remains controversial. Thus, we performed a systematic review and meta-analysis to assess the diagnostic accuracy of serum HE4 for lung cancer. We conducted a comprehensive literature search in PubMed, EMBASE, Chinese National Knowledge Infrastructure (CNKI), and WANFANG databases between Jan. 1966 and Nov. 2014. The diagnostic sensitivity (SEN), specificity (SPE), positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and summary receiver operating characteristic curve (SROC) were pooled by Meta-DiSc 1.4 software. A total of seven articles including 715 cases and 549 controls were included for analysis. The summary estimates for serum HE4 in the diagnosis of lung cancer in these studies were pooled SEN 0.72 (95% CI: 0.68–0.75), SPE 0.85 (95% CI: 0.81–0.88), PLR 4.68 (95% CI: 3.23–6.78), NLR 0.31 (95% CI: 0.24–0.39), and DOR 17.14 (95% CI: 9.72–30.20), and the area under the curve (AUC) was 0.8557. This meta-analysis indicated that serum HE4 is a potential tool in the diagnosis of lung cancer. In addition, considering the high heterogeneity and potential publication bias, further studies with rigorous design and large sample size are needed in the future.


2021 ◽  
Vol 2021 ◽  
pp. 1-8
Author(s):  
Xinchun He ◽  
Liang Chen ◽  
Haiou Chen ◽  
Yuqing Feng ◽  
Baining Zhu ◽  
...  

The purpose of our studies was to systematically assess the accuracy and clinical value of plasma calcitonin in patients with liver failure complicated with bacterial infection. In this study, we included prospective observational studies or randomized controlled trials on PCT. The quality of the studies was evaluated using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. Heterogeneity, pooled diagnostic odds ratio (DOR), pooled sensitivity, pooled specificity, pooled positive likelihood ratio, pooled negative likelihood ratio, the area under the summary receiver operating characteristic curve (SROC), and metaregression analysis were performed using Stata16.0 software. Consequently, the studies revealed substantial heterogeneity (I2 = 96, 95% confidence interval (95% CI) = 94–99). The results of meta-analysis using random effect models suggested that the combined DOR was 10.67 (95% CI = 3.73–30.53). In addition, the threshold effect analysis showed that the threshold effect was 0.23 and the correlation coefficient was −0.48, indicating that there was no threshold effect. In the forest map, the DOR of each study and the combined DOR are not distributed along the same line, and Q = 2.2 × 1014, P ≤ 0.001 . Furthermore, the metaregression analysis of PCT study design, bacterial infection site, and mean age displayed that the P values were >0.05. The combined sensitivity was 0.77 (95% CI = 0.54–0.90), the combined specificity was 0.76 (95% CI = 0.70–0.82), the combined positive likelihood ratio was 3.25 (95% CI = 2.33–4.52), the combined negative likelihood ratio was 0.30 (95% CI = 0.14–0.67), and the combined AUC was 0.80 (95% CI = 0.76–0.83). In conclusion, PCT has moderate diagnostic value for adult liver failure complicated with bacterial infection, and it is a better auxiliary diagnostic index for liver failure with bacterial infection. However, the results of procalcitonin must be carefully interpreted combined with medical history, physical examination, and microbiological assessment.


2015 ◽  
Vol 81 (6) ◽  
pp. 626-629 ◽  
Author(s):  
Bing Xiong ◽  
Baishu Zhong ◽  
Zhenwei Li ◽  
Feng Zhou ◽  
Ruying Hu ◽  
...  

The aim of the study is to evaluate the diagnostic accuracy of noncontrast CT in detecting acute appendicitis. Prospective studies in which noncontrast CT was performed to evaluate acute appendicitis were found on PubMed, EMBASE, and Cochrane Library. Pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were assessed. The summary receiver-operating characteristic curve was conducted and the area under the curve was calculated. Seven original studies investigating a total of 845 patients were included in this meta-analysis. The pooled sensitivity and specificity were 0.90 (95% CI: 0.86–0.92) and 0.94 (95% CI: 0.92–0.97), respectively. The pooled positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio was 12.90 (95% CI: 4.80–34.67), 0.09 (95% CI: 0.04–0.20), and 162.76 (95% CI: 31.05–853.26), respectively. The summary receiver-operating characteristic curve was symmetrical and the area under the curve was 0.97 (95% CI: 0.95–0.99). In conclusion, noncontrast CT has high diagnostic accuracy in detecting acute appendicitis, which is adequate for clinical decision making.


2021 ◽  
Vol 11 ◽  
Author(s):  
Xiaotong Huang ◽  
Ziwei Wang ◽  
Meiqin Zhang ◽  
Hong Luo

ObjectivesTo evaluate the diagnostic accuracy of the ADNEX model for ovarian cancer at the 15% cut-off value.MethodsStudies on the identified diagnosis of the ADNEX model for ovarian cancer published in PubMed, Embase, the Cochrane Library and Web of Science databases from January 1st, 2014 to February 20th, 2021 were searched. Two researchers independently screened the retrieved studies and extracted the basic features and parameter data. The quality of the eligible studies was evaluated by Quality Assessment of Diagnostic Accuracy Studies-2, and the result was summarized by Review Manager 5.3. Meta-Disc 1.4 and STATA 16.0 were used in statistical analysis. Heterogeneity of this meta-analysis was calculated. Meta-regression was performed to investigate the potential sources of heterogeneity. Sensitivity analysis and Deek’s funnel plot analysis were conducted to evaluate the stability and publication bias, respectively.Results280 studies were initially retrieved through the search strategy, and 10 eligible studies were ultimately included. The random-effects model was selected for data synthesis. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio and the area under the summary receiver operating characteristic curve were 0.92 (95% CI: 0.89–0.94), 0.82 (95% CI: 0.78–0.86), 5.2 (95% CI: 4.1–6.4), 0.10 (95% CI: 0.07–0.13), 54.0 (95% CI: 37.0–77.0) and 0.95 (95% CI: 0.91–0.95). Meta-regression based on study design, country, enrollment and blind method was not statistically significant. This meta-analysis was stable with no obvious publication bias.ConclusionsThe ADNEX model at the 15% cut-off had high diagnostic accuracy in identifying ovarian cancer.


2021 ◽  
Vol 20 ◽  
pp. 153303382110119
Author(s):  
Wen-Ting Zhang ◽  
Guo-Xun Zhang ◽  
Shuai-Shuai Gao

Background: Leukemia is a common malignant disease in the human blood system. Many researchers have proposed circulating microRNAs as biomarkers for the diagnosis of leukemia. We conducted a meta-analysis to evaluate the diagnostic accuracy of circulating miRNAs in the diagnosis of leukemia. Methods: A comprehensive literature search (updated to October 13, 2020) in PubMed, EMBASE, Web of Science, Cochrane Library, Wanfang database and China National Knowledge Infrastructure (CNKI) was performed to identify eligible studies. The sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and area under the curve (AUC) for diagnosing leukemia were pooled for both overall and subgroup analysis. The meta-regression and subgroup analysis were performed to explore heterogeneity and Deeks’ funnel plot was used to assess publication bias. Results: 49 studies from 22 publications with a total of 3,489 leukemia patients and 2,756 healthy controls were included in this meta-analysis. The overall sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio and area under the curve were 0.83, 0.92, 10.8, 0.18, 59 and 0.94, respectively. Subgroup analysis shows that the microRNA clusters of plasma type could carry out a better diagnostic accuracy of leukemia patients. In addition, publication bias was not found. Conclusions: Circulating microRNAs can be used as a promising noninvasive biomarker in the early diagnosis of leukemia.


BMJ Open ◽  
2020 ◽  
Vol 10 (12) ◽  
pp. e038088
Author(s):  
Jacky Tu ◽  
Peter Gowdie ◽  
Julian Cassar ◽  
Simon Craig

BackgroundSeptic arthritis is an uncommon but potentially significant diagnosis to be considered when a child presents to the emergency department (ED) with non-traumatic limp. Our objective was to determine the diagnostic accuracy of clinical findings (history and examination) and investigation results (pathology tests and imaging) for the diagnosis of septic arthritis among children presenting with acute non-traumatic limp to the ED.MethodsSystematic review of the literature published between 1966 and June 2019 on MEDLINE and EMBASE databases. Studies were included if they evaluated children presenting with lower limb complaints and evaluated diagnostic performance of items from history, physical examination, laboratory testing or radiological examination. Data were independently extracted by two authors, and quality assessment was performed using the Quality Assessment Tool for Diagnostic Accuracy Studies 2 tool.Results18 studies were identified, and included 2672 children (560 with a final diagnosis of septic arthritis). There was substantial heterogeneity in inclusion criteria, study setting, definitions of specific variables and the gold standard used to confirm septic arthritis. Clinical and investigation findings were reported using varying definitions and cut-offs, and applied to differing study populations. Spectrum bias and poor-to-moderate study design quality limit their applicability to the ED setting.Single studies suggest that the presence of joint tenderness (n=189; positive likelihood ratio 11.4 (95% CI 5.9 to 22.0); negative likelihood ratio 0.2 (95% CI 0.0 to 1.2)) and joint effusion on ultrasound (n=127; positive likelihood ratio 8.4 (95% CI 4.1 to 17.1); negative likelihood ratio 0.2 (95% CI 0.1 to 0.3)) appear to be useful. Two promising clinical risk prediction tools were identified, however, their performance was notably lower when tested in external validation studies.DiscussionDifferentiating children with septic arthritis from non-emergent disorders of non-traumatic limp remains a key diagnostic challenge for emergency physicians. There is a need for prospectively derived and validated ED-based clinical risk prediction tools.


2021 ◽  
Vol 15 (11) ◽  
pp. e0009869
Author(s):  
Zhuo-Lei Li ◽  
Qi-Bing Luo ◽  
Shan-Shan Xiao ◽  
Ze-Hong Lin ◽  
Ye-Ling Liu ◽  
...  

Purpose Vancomycin-resistant enterococci infection is a worrying worldwide clinical problem. To evaluate the accuracy of GeneXpert vanA/vanB in the diagnosis of VRE, we conducted a systematic review in the study. Methods Experimental data were extracted from publications until May 03 2021 related to the diagnostic accuracy of GeneXpert vanA/vanB for VRE in PubMed, Embase, Web of Science and the Cochrane Library. The accuracy of GeneXpert vanA/vanB for VRE was evaluated using summary receiver to operate characteristic curve, pooled sensitivity, pooled specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio. Results 8 publications were divided into 3 groups according to two golden standard references, vanA and vanB group, vanA group, vanB group, including 6 researches, 5 researches and 5 researches, respectively. The pooled sensitivity and specificity of group vanA and vanB were 0.96 (95% CI, 0.93–0.98) and 0.90 (95% CI, 0.88–0.91) respectively. The DOR was 440.77 (95% CI, 37.92–5123.55). The pooled sensitivity and specificity of group vanA were 0.86 (95% CI, 0.81–0.90) and 0.99 (95% CI, 0.99–0.99) respectively, and those of group vanB were 0.85 (95% CI, 0.63–0.97) and 0.82 (95% CI, 0.80–0.83) respectively. Conclusion GeneXpert vanA/vanB can diagnose VRE with high-accuracy and shows greater accuracy in diagnosing vanA.


Author(s):  
Fatma Hegazy ◽  
Emad Aboelnasr ◽  
Amr A. Abdel-Aziem ◽  
In-Ju Kim

Background: Clinical diagnosis of Paediatric flexible flatfoot is still a challenging issue for the healthcare professionals. Clarke's Angle (CA) is frequently used clinically for assessing foot posture; however there is still a debate about its validity and diagnostic accuracy in evaluation of static foot posture especially in Paediatric population with some previous studies supporting, while the others are refuting its validity. The current study aimed to investigate validity and diagnostic accuracy of CA using radiographic findings as a criterion standard measure to determine flexible flatfoot between ages of 6-18 years. Methods: A cross-sectional study conducted on 612 participants (1224 feet) with flexible flatfoot aged 6-18 years (12.36 {plus minus}3.39) was recruited. The clinical measures results were compared to the criterion standard radiographic measures and displayed on the receiver operating characteristic curve (ROC) and the area under ROC curve (AUC) was computed. Intra-rater reliability, sensitivity, specificity, predictive values, and likelihood ratios were calculated for CA. Fagan nomogram was used to detect the posttest probability. Results: Clarke's angle (CA) demonstrated higher intra-rater reliability (ICC=0.99). CA showed higher sensitivity (98.4%), specificity (98.8), positive predictive value (97.3), negative predictive value (99.3), positive likelihood ratio (84) and negative likelihood ratio (0.02). AUC was 0.98[95%CI= 0095-1.00]. The positive likelihood ratio (LR+) yielded a posttest probability of 97%, while the negative likelihood ratio (LR−) yielded a posttest probability of 0.02. Conclusions: CA is a valid with high diagnostic accuracy in diagnosis of flexible flatfoot between the ages of 6-18 years.


Author(s):  
Amita Ray ◽  
Divya S. ◽  
B. N. Kumar Guru ◽  
A. S. Ramaswamy ◽  
Bharat Kumar

Background: Identification of the nature of an adnexal mass can ensure optimum management. Single parameters as well as diagnostic models using a combination of several parameters are in use. The International Ovarian Tumor Analysis (IOTA) consortium has developed and published the Assessment of Different NEoplasias in the adneXa (ADNEX) model, which differentiates between benign and malignant masses. Authors conducted this study with the aim of finding a cut off value for this model in the study population and comparing the diagnostic accuracy of this model to that of the risk of malignancy (RMI).Methods: Women with adnexal masses admitted to the 3 medical college affiliated hospitals for surgical management were included in this study. Appropriate investigations were done to calculate the RMI-I and ADNEX score for each participant. A cut off score for the ADNEX model was determined and diagnostic accuracy tests were done for comparison.Results: At a cut-off of 29 for the ADNEX model and 200 for RMI model the sensitivity was 75% and 77.8, specificity 100% and 80.6%; Positive Predictive Value (PPV) 100%and 60%; Negative Predictive Value (NPV) 91% and 90.6%; Positive Likelihood ratio of infinity and 4 and a negative Likelihood Ratio of 2.8 and 2.5 respectively.Conclusions: The ADNEX model rates higher than the RMI in almost all tests of diagnostic accuracy and can be used for triaging, framing a referral policy and prioritizing surgery.


2019 ◽  
Vol 11 (10) ◽  
pp. 1019-1023 ◽  
Author(s):  
Santhosh Kumar Kannath ◽  
Adhithyan Rajendran ◽  
Bejoy Thomas ◽  
Jayadevan Enakshy Rajan

BackgroundTo date, very little study of the importance of a volumetric T2-weighted MR sequence in the evaluation of spinal vascular malformations (SVMs) has been carried out.ObjectiveTo determine the utility and accuracy of a volumetric T2 MR sequence compared with conventional T2 in the diagnosis of SVMs.MethodsRetrospective analysis of all patients who underwent spinal DSA for suspected SVMs was conducted. Conventional T2 and volumetric T2 MR images were analysed for the presence of flow voids and parenchymal changes, and SVMs were characterized. The sensitivity, specificity, and overall diagnostic accuracy of these MRI diagnoses were calculated.ResultsOf 89 subjects included in the final analysis, 70 patients had angiographically proved SVMs (38 patients with spinal cord arteriovenous malformations [SCAVM—intramedullary or perimedullary] and 32 cases of spinal dural arteriovenous fistula (SDAVF)) and the remaining 19 subjects were normal. The sensitivity and specificity for identification of SVMs were 98.1% and 90% for volumetric T2 sequences, compared with 82.8% and 89.4% for conventional T2 MRI, respectively. For characterization of spinal vascular lesions, volumetric MRI showed high sensitivity, specificity, and accuracy for SDAVF (100%, 90%, 97%, respectively) compared with conventional T2 MRI (71.8%, 89%, 79%, respectively). The positive likelihood ratio was high and negative likelihood ratio was zero for volumetric MRI evaluation of SDAVF, while these ratios were comparable between the two sequences for SCAVM.ConclusionVolumetric T2 MRI is highly sensitive for the detection of SVMs, especially for SDAVF. Volumetric T2 MRI could be introduced into routine clinical practice in the screening of suspected SVMs.