scholarly journals Adaptive ANN based differential protective relay for reliable power transformer protection operation during energisation

Author(s):  
Azniza Ahmad ◽  
Mohammad Lufti Othman ◽  
Kurreemun Khudsiya Bibi Zainab ◽  
Hashim Hizam

Power transformer is the most expensive equipment in electrical power system that needs continuous monitoring and fast protection response. Differential relay is usually used in power transformer protection scheme. This protection compares the difference of currents between transformer primary and secondary sides, with which a tripping signal to the circuit breaker is asserted. However, when power transformers are energized, the magnetizing inrush current is present and due to its high magnitude, the relay mal-operates. To prevent mal-operation, methods revolving around the fact that the relay should be able to discriminate between the magnetizing inrush current and the fault current must be studied. This paper presents an Artificial Neural Network(ANN) based differential relay that is designed to enable the differential relay to correct its mal-operation during energization by training the ANN and testing it with harmonic current as the restraining element. The MATLAB software is used to implement and evaluate the proposed differential relay. It is shown that the ANN based differential relay is indeed an adaptive relay when it is appropriately trained using the Network Fitting Tool. The improved differential relay models also include a reset part which enables automatic reset of the relays. Using the techniques of 2nd harmonic restraint and ANN to design a differential relay thus illustrates that the latter can successfully differentiate between magnetizing inrush and internal fault currents. With the new adaptive ANN-based differential relay, there is no mal-operation of the relay during energization. The ANN based differential relay shows better performance in terms of its ability to differentiate fault against energization current. Amazingly, the response time, when there is an internal fault, is 1 ms compared to 4.5 ms of the conventional 2nd harmonic restraint based relay.

2019 ◽  
Vol 8 (3) ◽  
pp. 7627-7630

This paper presents wavelet transform method for the analysis of differential currents of power transformer which can act as an accurate classifier between magnetizing inrush current and internal faults to avoid the needless tripping of circuit breaker. The differential protection scheme occasionally mal – operate whenever magnetizing inrush occurs in power transformer. The aim is to reduce the rate and time duration of undesired outages of power transformer. This includes the necessities of reliability with zero mal – operation of differential relay. The result shows higher operating speed with less fault clearing time. Wavelet Transform is employed for the analysis of transient signals under various conditions, which extracts data from signals in time and frequency domain simultaneously. The simulation is done in MATLAB environment.


Energies ◽  
2021 ◽  
Vol 14 (24) ◽  
pp. 8284
Author(s):  
Abdul Azeem ◽  
Majid Jamil ◽  
Shamimul Qamar ◽  
Hasmat Malik ◽  
Rayees Ahmad Thokar

In this paper, the authors have developed a hardware model for blocking even and odd harmonics of a power transformer. In the proposed hardware model, intelligent differential & over-current relays are used for the blocking of harmonics of a power transformer. The harmonic restraint function on the differential relay (7UT61) prevents the relay from tripping during transformer magnetizing inrush current. However, the over-current relays which are used for back up protection does not have a harmonic restraint element, and over-current relay trips due to magnetizing inrush current, causes unwanted interruptions and power failures. The establishment of harmonic blocking scheme for over-current protection in power transformers is an important finding of this research study. IEC61850 standard-Based GOOSE (Generic Object Oriented Substation Event) applications used in power transformer protection for fast detecting and clearing of faults is an interested study presented in the proposed work.


2014 ◽  
Vol 960-961 ◽  
pp. 995-999
Author(s):  
Wei Cai ◽  
Lin Sun ◽  
Hua Ren Wu

This paper establishes a simulation model of a simplified power system with transformer differential protection based on an embedded Matlab function block. The differential protection consists of percentage restraint differential protection, second harmonic restraint, differential current instantaneous trip protection and over-excitation protection. The model is able to correctly simulate the transformer’s inrush current and internal and external faults. The results from the simulation show that the circuit breaker correctly operates for a transformer internal fault and provides a good braking effect for an external fault. In addition, the protection model is able to identify the inrush current of the transformer and avoid a protection mis-trip event.


2018 ◽  
Vol 7 (4.5) ◽  
pp. 126 ◽  
Author(s):  
Mudita Banerjee ◽  
Dr. Anita Khosla

This paper presents the second harmonics present in the primary current of a power transformer at different conditions using Fast Fourier Transform and Total Harmonic Distortion techniques to analyze the inrush condition and to distinguish it with fault condition of a power transformer. Result shows that the 2nd harmonic content is pre-dominant in inrush condition of primary current of the power transformer. It is observed that there are significant differences amongst the parameters found during inrush condition, normal condition and internal fault condition which are useful in the identification of magnetizing inrush current of power transformer. The simulation is done in MATLAB/SIMULINK. 


2020 ◽  
Vol 10 (10) ◽  
pp. 20-32
Author(s):  
Aleksey A. KUVSHINOV ◽  
◽  
Vera V. VAKHNINA ◽  
Aleksey N. CHERNENKO ◽  
◽  
...  

The mathematical model of a shell-core power transformer’s magnetization branch is substantiated. By using the model, analytical expressions for the magnetizing current instantaneous values under the conditions of geomagnetic disturbances can be obtained. Quantitative assessments of the magnetizing inrush current amplitudes and durations versus the geomagnetic disturbance intensity are obtained. The dynamics of the power transformer magnetic system saturation transient and changes in the magnetization inrush current amplitudes and durations after a sudden occurrence of geomagnetic disturbances are shown. The error of estimating the magnetizing inrush current amplitudes under geomagnetic disturbances is determined based on comparison with experimental data.


This paper presents a new innovative algorithm for Numerical Differential Relay design of transformer. Fault information is critical for operating and maintaining power networks. This algorithm provides accurate performance for transformer by which is independent of system conditions such as: External fault, Inrush current, CT saturation. Locating transformer faults quickly and accurately is very important for economy, safety and reliability point of view. Both fault-detection and protection indices are derived by using Numerical Differential Relay algorithm design of transformer. The embedded based differential and operating current measurement device is called numerical differential relay is among the most important development in the field of instantaneous fault operation. Numerical relay provides measurement of differential current and operating current at power transformer above 5MVA in substation. Simulation studies are carried out using MATLAB Software show that the proposed scheme provides a high accuracy and fast relay response in internal fault conditions. Current transformers form an important part of protective systems. Ideal Current Transformers (CTs) are expected to reflect the primary current faithfully on the secondary side. Under conditions the CT saturates, and hence it cannot reproduce the primary current faithfully. This paper deals with simulation methods for determining CT performance under different factor. A Simulink model has been developed to observe CT response under steady state w.r.t Burden, Turns ratio, Asymmetrical current, Hysteresis conditions. Thus, it is now possible to evaluate the CT performance under these factors


2015 ◽  
Vol 793 ◽  
pp. 65-69 ◽  
Author(s):  
Abadal Salam T. Hussain ◽  
Waleed A. Oraibi ◽  
Fadhel A. Jumaa ◽  
F. Malek ◽  
Syed F. Ahmed ◽  
...  

Electrical Power System protection is required to protectboth the user and the system equipment itself fromany fault, hence electrical power system is not allowed to operate without any protection devices installed. Power System fault is defined as the undesirable condition that occurs in the power system. Some of these undesirable conditions are short circuit, current leakage, ground faultand over-under voltage. With the increasing loads, voltages and short-circuit duty in power plant, over voltage protection has become more important today. Here, the component that had been used is PIC 16F877a microcontroller to control the whole system and especially on the circuit breakers as well as the LCT display unit is used to display the voltage level and type of generator that used to serve the load. Sensors are used to measure both thevoltage and the load. The controlled digital signal from PIC microcontroller is converted by using the digital analog converter to control the whole circuit. Thus a device called protective relay is created to meet this requirement. The protective relay is mostlyoften coupled with circuit breaker in a way that it can isolate the abnormal condition in the system.


2014 ◽  
Vol 492 ◽  
pp. 426-430
Author(s):  
Rachid Bouderbala ◽  
Hamid Bentarzi

A differential relay that is very sensitive relay operating even at its limits may be used for protecting a power transformer. However, this characteristic may lead to unnecessary tripping due to transient currents. In order to avoid this unnecessary tripping, estimated harmonics of these currents may be required which need great computation efforts. In this paper, a new frame work is proposed using PC interfaced with a data acquisition card AD622, which acquires real-time signals of the currents, process them numerically in the computer and outputs tripping signal to the circuit breaker. All algorithms of differential protection function and blocking techniques have been implemented using the Simulink/Matlab. To validate the present work, the performance of developed relay is tested by signals generated by Simulink/MATLAB simulator under different conditions. The test results show that this proposed scheme provides good discrimination between the transient currents and the internal fault currents.