scholarly journals Characterization of the scope and magnitude of biotin interference in susceptible Roche Elecsys competitive and sandwich immunoassays

Author(s):  
Christina Trambas ◽  
Zhong Lu ◽  
Tina Yen ◽  
Ken Sikaris

Background Biotin interference is a significant problem to which at-risk laboratories must now be attuned. We sought to systematically characterize the nature of this interference in Roche immunoassays. Methods Known concentrations of biotin were titrated into serum samples and the effects on competitive and sandwich immunoassays were analysed. The maximum and minimum concentrations examined reflect those likely to be achieved in individuals on 5 to 10 mg supplements at the lower end, and 100 to 300 mg biotin at the high end. Results A high variability in biotin tolerance was observed. Some assays, such as troponin T, TSH and antithyroid antibodies, were extremely sensitive to the lower concentrations of biotin (15.6 and 31.3 ng/mL), whereas the majority of assays were relatively resistant. At concentrations ≥500 ng/mL, all assays showed significant interference from biotin but, again, the magnitude of the interference was variable. The more sensitive assays showed profound analytical bias at biotin concentrations that occur with high-dose therapy. Conclusion Our data demonstrate high variability in biotin tolerance across Roche immunoassays. The shape of the dose–response curves provides more detailed information than the single manufacturer-quoted figure for biotin tolerance. Accordingly, these data may be used by laboratories for more accurate risk assessment in predicting the effects of biotin. Our data may also be extrapolated to guide timing of blood tests in patients on high-dose biotin therapy: it demonstrates the number of half-lives required to withhold biotin in order to decrease its concentration to below a given assay tolerance.

1998 ◽  
Vol 17 (8) ◽  
pp. 454-459 ◽  
Author(s):  
Angelo Turturro ◽  
Bruce Hass ◽  
Ronald W Hart

Hormesis can be considered as a parameter which has a non-monotonic relationship with some endpoint. Since caloric intake is such a parameter, and the impact of this parameter on risk assessment has been fairly well characterized, it can provide clues as to how to integrate the information from a hormetic parameter into risk assessments for toxicants. Based on the work with caloric intake, one could: (a) define a biomarker for hormetic effect; (b) integrate specific information on when in the animals lifespan the parameter is active to influence parameters such as survival; (c) evaluate component effects of the overall hormetic response; and (d) address the consequences of a non-monotonic relationship between the hormetic parameter and endpoints critical for risk assessment. These impacts on risk assessments have been characterized for chronic tests, but are also true for short-term tests. A priority is the characterization of the dose-response curves for hormetic parameters. This quantification will be critical in utilizing them in risk assessment. With this information, one could better quantitatively address the changes one expects to result from the hormetic parameter, and limit the uncertainty and variability which occurs in toxicity testing.


1980 ◽  
Vol 26 (13) ◽  
pp. 1902-1904 ◽  
Author(s):  
R G Buice ◽  
W E Evans ◽  
J Karas ◽  
C A Nicholas ◽  
P Sidhu ◽  
...  

Abstract We evaluated three commonly used clinical methods for measuring serum methotrexate: enzyme immunoassay (EMIT), radioassay, and radioimmunoassay. Because potentially interfering compounds can be resolved by liquid chromatography, this method was selected as the comparison method. Patients’ serum samples, taken during 24 h after 6-h high-dose infusions, contained methotrexate in concentrations ranging from 10(-7) to 10(-4) mol/L. Chromatograms revealed substantial amounts of 7-hydroxymethotrexate in all samples, actually exceeding methotrexate by 12 and 24 h. Nevertheless, analysis of variance revealed no significant differences in results by any of the four methods, nor did results by the three test methods differ significantly after being adjusted by analysis of covariance with liquid chromatography as the covariate. Evidently any of the four techniques is suitable for monitoring serum methotrexate for 24 h after high-dose therapy.


2006 ◽  
Author(s):  
Matthew W. Johnson ◽  
Lawrence P. Carter ◽  
Annie Umbricht ◽  
Roland R. Griffiths

Tick-borne encephalitis virus (TBEV) was isolated for the first time in Sweden in 1958 (from ticks and from 1 tick-borne encephalitis [TBE] patient).1 In 2003, Haglund and colleagues reported the isolation and antigenic and genetic characterization of 14 TBEV strains from Swedish patients (samples collected 1991–1994).2 The first serum sample, from which TBEV was isolated, was obtained 2–10 days after onset of disease and found to be negative for anti-TBEV immunoglobulin M (IgM) by enzyme-linked immunosorbent assay (ELISA), whereas TBEV-specific IgM (and TBEV-specific immunoglobulin G/cerebrospinal fluid [IgG/CSF] activity) was demonstrated in later serum samples taken during the second phase of the disease.


2020 ◽  
Vol 45 (5) ◽  
pp. 491-498
Author(s):  
Fatih Yesildal ◽  
Ferruh Kemal Isman

AbstractObjectiveCOVID-19 pandemia still continues to threaten the whole world. High dose ascorbic acid (AA) infusion is a choice of treatment and its efficiency is still being investigated. AA interferes with many clinical chemistry tests. However, data about the interference of high concentrations of AA is not sufficient. In this study, we aimed to investigate the interference of AA at high concentrations on commonly used chemistry assays.Materials and MethodsSerum samples at AA concentrations of 200, 150, 100, 75, 50, 25, 10, 5, 2 and 0 mg/dL were prepared by using the stock solution of 15000 mg/dL AA. Each sample was analyzed by using the most common 30 chemistry tests (Abbott Architect C8000, Illinois, USA) and a POCT glucometer (STANDARD GlucoNavii, Gyeonggi-do, Republic of Korea).ResultsCreatinine, sodium and glucose (POCT) tests were found to be positively interfered by increasing AA concentrations; while direct bilirubin, lipase, UIBC, triglyceride, total cholesterol, HDL/LDL cholesterol tests were negatively interfered. Absolute interference (%) increased as the AA concentration increased.ConclusionThis is the largest and first study to investigate the interference of high dose AA, which is used in severe COVID-19 patients nowadays. Manufacturers and clinicians should be aware of the possibility of aberrant results due to high dose AA infusion. Clinicians should not forget to consult a laboratory specialist, since he is the only person to monitor the reactions in all assays, and know the technical subjects like interferences, assay method specifications. This issue is very important for correct decision-making and interpretation of the data-mining studies accurately and efficiently.


Sign in / Sign up

Export Citation Format

Share Document