Rheology of Fluoride Gels

1976 ◽  
Vol 55 (3) ◽  
pp. 353-356 ◽  
Author(s):  
M. Braden ◽  
Ratna Perera

Six commercial fluoride gels have been studied, using a cone and plate viscometer. Also, the thickening agents have been analyzed using infrared spectroscopy. All gels showed stress thinning, which is the decrease of viscosity with shear rate. Such shear rate dependence is clinically convenient in that the gel will flow readily at the high shear stresses present when the gel is applied but will not flow readily under its own weight when on the tooth. Five materials containing hydroxyalkyl celluloses showed similar degrees of shear thinning. One material with a non-cellulosic thickener showed much more extreme stress thinning together with elastic behavior at low shear rates; such behavior may be clinically advantageous. All of the gels showed only slight temperature dependence of rheological properties.

2021 ◽  
Vol 15 (3) ◽  
pp. 181-190
Author(s):  
Elif H Ozcan Cetin ◽  
Mehmet S Cetin ◽  
Mustafa B Ozbay ◽  
Hasan C Könte ◽  
Nezaket M Yaman ◽  
...  

Aim: We aimed to assess the association of whole blood with thromboembolic milieu in significant mitral stenosis patients. Methodology & results: We included 122 patients and classified patients into two groups as having thrombogenic milieu, thrombogenic milieu (+), otherwise patients without thrombogenic milieu, thrombogenic milieu (-). Whole blood viscosity (WBV) in both shear rates were higher in thrombogenic milieu (+) group comparing with thrombogenic milieu (-). WBV at high shear rate and WBV at low shear rate parameters were moderately correlated with grade of spontaneous echo contrast. Adjusted with other parameters, WBV parameters at both shear rates were associated with presence of thrombogenic milieu. Discussion & conclusion: We found that extrapolated WBV at both shear rates was significantly associated with the thrombogenic milieu in mitral stenosis. This easily available parameter may provide additional perspective about thrombogenic diathesis.


1992 ◽  
Vol 289 ◽  
Author(s):  
John R. Melrose

AbstractAn overview is given of theories of aggregates under flow. These generally assume some sort of structural breakdown as the shear rate is increased. Models vary with both the rigidity of the bonding and the level of treatment of hydrodynamics. Results are presented for simulations of a Rouse model of non-rigid, (i.e. central force) weakly bonded aggregates. In large scale simulations different structures are observed at low and high shear rates. The change from one structure to another is associated with a change in the rate of shear thinning. The model captures low shear rate features of real systems absent in previous models: this feature is ascribed to agglomerate deformations. Quantitatively, the model is two orders of magnitude out from experiment but some scaling is possible.


Blood ◽  
2009 ◽  
Vol 114 (22) ◽  
pp. 1518-1518
Author(s):  
Tamas Alexy ◽  
Thomas D. Coates ◽  
John C Wood ◽  
Herbert J. Meiselman ◽  
Rosalinda B Wenby ◽  
...  

Abstract Abstract 1518 Poster Board I-541 Introduction Chronic blood transfusions are commonly used as therapy for sickle cell disease (SCD, HbSS) in order to improve oxygen delivery and minimize complications such as stroke in high-risk children. Vaso-occlusive crises can occur in regions of high shear flow (e.g., major cerebral artery occlusions) or regions of low shear flow (e.g., marrow infarct) leading to acute ischemia and, if severe, to necrosis of affected tissues. Transfusion with normal (AA) RBC causes an increase of hematocrit (H) that is complicated by two opposing factors: increased hematocrit (H) causes a linear increase of oxygen carrying capacity and also an exponential increase of blood viscosity (η). As a consequence, the calculated oxygen transport effectiveness, defined as the ratio of H to η (H/η), is a biphasic function of hematocrit: H/η initially increases with H, reaches a maximum at an optimal H value, and then declines with further increases of H. At equal H and shear rate, sickle (SS) blood has significantly higher viscosity than AA and hence part of the strategy for transfusing SCD patients is to reduce η so as to improve H/η. Viscosity studies at high shear rates indicate that an optimum H can be demonstrated for AA-SS RBC mixtures prepared by adding AA RBC to SS blood to simulate transfusion. In marked contrast, low shear rate results for AA-SS mixtures indicate that there is no optimum hematocrit and H/η always decreases with increasing H (Transfusion 46:912-918, 2006). In order to extend these previous in vitro observations to SCD patients, we have measured blood viscosity and hematocrit using whole blood samples acquired prior to and following routine therapeutic transfusion; H/η was calculated over a wide, physiologically relevant shear rate range. Methods All subjects (n= 8, mean age =18.7 years) had homozygous HbSS disease, were crisis-free for > 4 weeks, and were enrolled in a chronic transfusion protocol designed to yield < 30% HbS and a post-transfusion H of 30-35%. Blood samples were obtained pre- and within 120 hours post-transfusion. A computer-controller tube viscometer was used to determine blood viscosity (37 °C, 40 mm Hg oxygen tension) over a shear rate range of 1 – 1,000 1/s. Results 1) As anticipated, blood viscosity and the degree of non-Newtonian flow behavior increased with H (24.7% pre-transfusion, 34.6% post-transfusion); 2) the change of H/η from pre- to post- transfusion was markedly affected by shear rate (Figure). As indicated, there is a large adverse effect at low shear (i.e., H/η reduced by 20-25% following transfusion), a neutral effect at about 50-100 1/s, and an improved H/η at high shear (Figure). That is, transfusion with AA RBC to obtain a lower percent SS RBC and a higher H actually impairs oxygen transport effectiveness at low shear and is only beneficial at high shear. Conclusions Clinical experience suggests that transfusion regimens aimed a keeping HbS at 30-50% are effective in preventing recurrent strokes in high-risk children. However, our new in vivo transfusion data suggest that at low shear rates, %HbS must be reduced further for H/η to surpass pre-transfusion levels. We interpret these findings as being consistent with our previous data for AA-SS RBC mixtures. They are also consistent with clinical results indicating lack of efficacy for transfusion in low flow areas (e.g., bone marrow during acute crisis) but highly beneficial effects in high flow regions (e.g., cerebral arteries). Our results thus suggest that benefits of transfusion may vary depending on local flow rates (i.e., shear rates) and organ-specific hemodynamics. Disclosures No relevant conflicts of interest to declare.


1990 ◽  
Vol 112 (3) ◽  
pp. 417-425 ◽  
Author(s):  
C. S. Peter Wu ◽  
T. Melodick ◽  
S. C. Lin ◽  
J. L. Duda ◽  
E. E. Klaus

A high-shear capillary viscometer was used to determine the viscosity of mineral oil lubricants containing an olefin copolymer up to shear rates of a million reciprocal seconds. Comprehensive measurements were conducted for a range of polymer concentrations from 1–3 wt percent polymer and a temperature range of 38–120° C. The experimental technique utilizes a theoretical analysis procedure to handle the complications associated with viscous heating, the influence of pressure on the viscosity, and the excess pressure drop which occur at the entrance and exit of the capillary. The viscosity of the polymer solutions is determined over the complete range of shear rate starting from the lower Newtonian limit, through the shear-thinning region, and finally, the Newtonian behavior at high shear rates. It is shown that the standard ASTM plot for viscosity-temperature behavior can be used to correlate the viscous behavior for a given polymer concentration over this broad range of shear rates and shear stresses.


Polymers ◽  
2018 ◽  
Vol 10 (11) ◽  
pp. 1204 ◽  
Author(s):  
L. Bravo-Anaya ◽  
Denis Roux ◽  
J. Soltero Martínez ◽  
Francisco Carvajal Ramos ◽  
Frédéric Pignon ◽  
...  

Previous investigations were conducted on two concentrations of DNA solution: 4 mg/mL, for which it has been shown that no supramolecular organization is induced under flow at low shear rates; and 10 mg/mL, in which a liquid crystalline-type texture is formed under flow at low shear rates, attesting to an orientation of pre-organized chains. Rheological experiments are discussed and their results supported by small-angle X-ray scattering (SAXS) and flow birefringence visualization experiments. Scattering from polyelectrolytes has a characteristic signal, which is here observed in SAXS, showing a strong correlation peak between charged chains in water, for both concentrations. This peak is weaker in the presence of 0.01 M NaCl and suppressed in salt excess at 0.1 M NaCl. No plateau in the σ( γ ˙ ) plot was observed in analysis of rheological experiments on low DNA concentration (4 mg/mL). As typically observed in polyelectrolyte systems both the dynamic moduli and shear viscosity were higher in water as electrostatic forces dominate, than in the presence of salt, especially at low shear rates. The rheological results for concentrations of 0.01 M NaCl are lower than in water as expected due to partial screening of electrostatic repulsions. Rheological data for concentrations of 0.1 M NaCl are unexpected. Electrostatic forces are partially screened in the low salt concentration, leading to a drop in the rheological values. For high salt concentration there are no longer interchain repulsions and so steric interactions dominate within the entangled network leading to the subsequent increase in rheological parameters. Regardless of the solvent, at high shear rates the solutions are birefringent. In the 10 mg/mL case, under flow, textures are formed at relatively low shear rate before all the chains align going to a pseudonematic liquid crystalline phase at high shear rate. The electrostatic repulsion between semi-rigid chains induces a correlation between the chains leading to an electrostatic pseudo-gel in water and loosely in 0.01 M NaCl at low stress applied. To the best of our knowledge, this is the first time that such behavior is observed. In 0.1 M NaCl, DNA behavior resembles the corresponding neutral polymer as expected for polyelectrolyte in salt excess, exhibiting a yield stress. When texture appears in water and in 0.01 M NaCl, a critical transition is observed in rheological curves, where the viscosity decreases sharply at a given critical shear stress corresponding to a plateau in the σ( γ ˙ ) plot also observed in creep transient experiment.


2012 ◽  
Vol 35 (6) ◽  
pp. 425-434 ◽  
Author(s):  
Won Kim ◽  
Sung Kwang Park ◽  
Kyung Pyo Kang ◽  
Dong Hwan Lee ◽  
Sam Yeon Kim ◽  
...  

Background: Elevated blood viscosity has been shown to be independently correlated with cardiovascular risk factors and associated with increased risk of major cardiovascular events, including death and acute myocardial infarction. The aim of the present study was to investigate changes in whole blood viscosity (WBV) at shear rates of 1, 5, and 300 s-1 before and after hemodialysis in patients with end-stage renal disease (ESRD). We also examined the relationship between the changes of WBV and intravascular blood volume. Methods: 43 patients with ESRD receiving maintenance hemodialysis were enrolled. WBV was measured using a scanning capillary tube viscometer pre- and post-dialysis to quantify dialytic viscosity surges. Body weight, blood pressure, and hematocrit were also measured before and after hemodialysis, as was the fluid removed during the session. Results: Hemodialysis had a 3 times greater impact on the low-shear WBV at a shear rate of 1 s-1 (i.e., 44.1% change) than on the high-shear WBV at a shear rate of 300 s-1 (i.e., 15.9% change). Changes in the low-shear WBV obtained at shear rates of 1 and 5 s-1 during hemodialysis were significantly correlated with changes in hematocrit. The intravascular blood volume reduction during hemodialysis was positively correlated with the changes in both high-shear and low-shear WBVs. Conclusions: These results suggest that the WBV parameter may hold additional information beyond hemoconcentration. Further research is needed to evaluate the relationship between low-shear WBV surges and increased morbidity in the patient population with ESRD.


2011 ◽  
Vol 106 (12) ◽  
pp. 1062-1068 ◽  
Author(s):  
Naoki Tsuji ◽  
Yuko Honda ◽  
Chikako Kamisato ◽  
Yoshiyuki Morishima ◽  
Toshiro Shibano ◽  
...  

SummaryEdoxaban is an oral, direct factor Xa (FXa) inhibitor under late-phase clinical development. This study compared the antithrombotic efficacy of edoxaban with that of an indirect FXa inhibitor, fondaparinux, in in vivo venous and arterial thrombosis models and in ex vivo perfusion chamber thrombosis model under low and high shear rates in rats. Venous and arterial thrombi were induced by platinum wire insertion into the inferior vena cava and by application of FeCl3 to the carotid artery, respectively. The perfusion chamber thrombus was formed by blood perfusion into a collagen-coated capillary at 150 s-1 (low shear rate) and 1,600 s-1 (high shear rate). Effective doses of edoxaban that reduced thrombus formation by 50% (ED50) in venous and arterial thrombosis models were 0.076 and 0.093 mg/kg/h, respectively. In contrast, ED50 of fondaparinux in the arterial thrombosis model (>10 mg/kg/h) was markedly higher compared to ED50 in the venous thrombosis model (0.021 mg/kg/h). In the perfusion chamber thrombosis model, the ratio of ED50 under high shear rate (1.13 mg/kg/h) to that under low shear rate (0.63 mg/kg/h) for edoxaban was 1.9, whereas that for fondaparinux was more than 66. While the efficacy of fondaparinux markedly decreased in arterial thrombosis and in a high-shear state, edoxaban exerted consistent antithrombotic effects regardless of flow conditions. These results suggest that shear rate is a key factor in different antithrombotic effects between edoxaban and fondaparinux.


Blood ◽  
1987 ◽  
Vol 70 (4) ◽  
pp. 1214-1217
Author(s):  
E Fressinaud ◽  
D Baruch ◽  
C Rothschild ◽  
HR Baumgartner ◽  
D Meyer

Although it is well established that plasma von Willebrand Factor (vWF) is essential to platelet adhesion to subendothelium at high shear rates, the role of platelet vWF is less clear. We studied the respective role of both plasma and platelet vWF in mediating platelet adhesion to fibrillar collagen in a parallel-plate perfusion chamber. Reconstituted blood containing RBCs, various mixtures of labeled washed platelets and plasma from controls or five patients with severe von Willebrand disease (vWD), was perfused through the chamber for five minutes at a shear rate of 1,600 s-1. Platelet-collagen interactions were estimated by counting the radioactivity in deposited platelets and by quantitative morphometry. When the perfusate consisted of normal platelets suspended in normal plasma, platelet deposition on the collagen was 24.7 +/- 3.6 X 10(6)/cm2 (mean +/- SEM, n = 6). Significantly less deposition (16 +/- 2.3) was observed when vWD platelets were substituted for normal platelets. In mixtures containing vWD plasma, significantly greater deposition (9 +/- 2.2) was obtained with normal than with vWD platelets (1 +/- 0.4) demonstrating a role for platelet vWF in mediating the deposition of platelets on collagen. Morphometric analysis confirmed these data. Our findings indicate that platelet, as well as plasma, vWF mediates platelet-collagen interactions at a high shear rate.


1981 ◽  
Author(s):  
L J Wurzinger ◽  
R Opitz ◽  
P Blasberg ◽  
K Bialonski ◽  
H Schmid-Schönbein

The fact that high shear activates and damages platelets has been suspected to be a major cause of thromboembolism in artificial internal organs (AIO) or in arterial stenosis. In AIO wall shear stresses well above 50 Nm-2 have been computed to which blood cells are exposed for times in the order of milliseconds (ms). Unfortunately, the studies on this subject employing defined flow conditions operate with exposure times higher than 10 seconds. The pupose of the present study was to elucidate the effects of high shear exposure for ms upon platelet function (ADP induced platelet aggregation (PA), platelet procoagulant activity {PF- 3)) under heparin anticoagulation, which is also used in AIO.To apply shear rates ranging from 50 - 220 Nm-2 to heparinized PRP for defined exposure times between 7 - 700 ms a flow through Couette-viscometer was employed. Platelet factor 3 (PF-3) availability was estimated by using a modified Stypven time technique. Lactic dehydrogenase (LDH) liberation was taken as a measure for platelet destruction. All steps of the experimental procedure were carried out at 37°C.From our data we conclude that, in the presence of physiological calcium levels (heparin anticoagulation) shear stresses and exposure times that certainly occur in AIO are able to activate platelets and procoagulant potential of blood.


Processes ◽  
2020 ◽  
Vol 8 (12) ◽  
pp. 1622
Author(s):  
Sahr Sana ◽  
Vladimir Zivkovic ◽  
Kamelia Boodhoo

Spinning disc technology is capable of achieving intensified micromixing within thin liquid films created through large shear rates, typically of the order of 103 s−1, generated by means of fast disc surface rotation. In this study the effect of the high shear on solvent–antisolvent mixing and starch nanoparticle precipitation is reported. Rheological studies of starch solutions at 2% w/v and 4% w/v have demonstrated their shear-thinning behaviour at the large shear rates experienced on the spinning disc surface. The effect of such high shear rate on starch nanoparticle precipitation is investigated alongside solute concentration and several other operating parameters such as flow rate, disc rotational speed, and solvent/antisolvent ratio. A reduction in nanoparticle size has been observed with an increase in starch concentration, although agglomeration was found to be more prevalent amongst these smaller particles particularly at larger flow rates and disc rotational speeds. Micromixing time, estimated on the basis of an engulfment mechanism, has been correlated against shear rate. With fast micromixing of the order of 1 ms observed at higher shear rates, and which are practically unaffected by the starch concentrations used, micromixing is not thought to be influential in determining the particle characteristics highlighted in this work.