Effects of External Bleaching on Indentation and Abrasion Characteristics of Human Enamel in vitro

1992 ◽  
Vol 71 (6) ◽  
pp. 1340-1344 ◽  
Author(s):  
R.R. Seghi ◽  
I. Denry

The application of home-bleaching procedures as a means of lightening multiple teeth has become increasingly popular. Very few studies, however, have determined the effect of this treatment upon dental hard tissues. This in vitro study evaluated the effects of a 10% carbamide peroxide gel on the apparent fracture toughness, hardness, and abrasion characteristics of human enamel. The apparent fracture toughness of enamel was reduced by about 30% after bleaching for a period of 12 hours with no significant change in surface hardness. Enamel treated with the bleaching gels also exhibited a small but significant decrease in abrasion resistance. This behavior was most likely due to an alteration of the organic matrix of enamel under the chemical action of hydrogen peroxide. Further investigation of the clinical significance of this process is needed.

2017 ◽  
Vol 63 (4) ◽  
pp. 3933-3945
Author(s):  
Khaled Haggag ◽  
Muhammad Abbas ◽  
Zainab EL Sharkawy

2009 ◽  
Vol 20 (1) ◽  
pp. 42-47 ◽  
Author(s):  
Fernando Henrique Ruppel Osternack ◽  
Danilo Biazzetto de Menezes Caldas ◽  
Rodrigo Nunes Rached ◽  
Sérgio Vieira ◽  
Jeffrey A. Platt ◽  
...  

This in vitro study evaluated the Knoop hardness of the composite resins Charisma® (C) and Durafill VS® (D) polymerized in 3 different conditions: at room temperature (A) (23 ± 1°C); refrigerated at 4 ± 1°C and immediately photo-activated after removal from the refrigerator (0); and, refrigerated at 4 ± 1°C and photo-activated after a bench time of 15 min at room temperature (15). One hundred and twenty specimens (4 mm diameter and 2 mm depth) were made using a stainless steel mold and following manufacturer's instructions. All specimens were tested immediately after polymerization (I) and after 7 days of water storage in the dark at room temperature (7d). The data were subjected to ANOVA and post-hoc Tukey's test (a=0.05). On the top surface, CAI was statistically similar to C15I and DAI to D15I (p>0.05). On the bottom surface, CAI presented higher hardness values when compared to COI and C15I (p<0.05). The D groups showed no significant differences (p>0.05) on the bottom surfaces for any tested polymerization condition. After 7 days of storage, the Knoop hardness decreased significantly (p<0.05) for groups C7d and D7d except for C07d, which was not different from COI at either surface (p>0.05). D07d showed higher Knoop hardness (p<0.05) values on the top surface when compared to the other groups.


2016 ◽  
Vol 9 (3) ◽  
pp. 1101-1105
Author(s):  
RAMACHANDRAN TAMILSELVI ◽  
RAJENDRAN MATHAN RAJAN ◽  
VERONICA ARUNA KUMARI ◽  
DEIVANAYAGAM KANDASWAMY

2013 ◽  
Vol 38 (2) ◽  
pp. 142-150 ◽  
Author(s):  
LE Tam ◽  
P Bahrami ◽  
O Oguienko ◽  
H Limeback

SUMMARY Purpose Although damage to the structural integrity of the tooth is not usually considered a significant problem associated with tooth bleaching, there have been some reported negative effects of bleaching on dental hard tissues in vitro. More studies are needed to determine whether the observed in vitro effects have practical clinical implications regarding tooth structural durability. Objectives This in situ study evaluated the effect of 10% and 15% carbamide peroxide (CP) dental bleach, applied using conventional whitening trays by participants at home, on the fracture toughness of dentin. Methods Ninety-one adult volunteers were recruited (n ≈ 30/group). Compact fracture toughness specimens (approximately 4.5 × 4.6 × 1.7 mm) were prepared from the coronal dentin of recently extracted human molars and gamma-radiated. One specimen was fitted into a prepared slot, adjacent to a maxillary premolar, within a custom-made bleaching tray that was made for each adult participant. The participants were instructed to wear the tray containing the dentin specimen with placebo, 10% CP, or 15% CP treatment gel overnight for 14 nights and to store it in artificial saliva when not in use. Pre-bleach and post-bleach tooth color and tooth sensitivity were also evaluated using ranked shade tab values and visual analogue scales (VASs), respectively. Within 24–48 hours after the last bleach session, the dentin specimens were tested for fracture toughness using tensile loading at 10 mm/min. Analysis of variance, Kruskal-Wallis, χ2, Tukey's, and Mann-Whitney U tests were used for statistical analysis. The level of significance was set at p&lt;0.05 for all tests, except for the Mann-Whitney U tests, which used a Bonferroni correction for post hoc analyses of the nonparametric data (p&lt;0.017). Results The placebo, 10% CP, and 15% CP groups contained 30, 31, and 30 participants, respectively. Mean fracture toughness (+ standard deviation) for the placebo, 10% CP, and 15% CP groups were 2.3 ± 0.9, 2.2 ± 0.7, and 2.0 ± 0.5 MPa*m1/2 respectively. There were no significant differences in mean fracture toughness results among the groups (p=0.241). The tooth sensitivity VAS scores indicated a significantly greater incidence (p=0.000) and degree of tooth sensitivity (p=0.049 for VAS change and p=0.003 for max VAS) in the bleach groups than in the placebo group. The color change results showed generally greater color change in the bleach groups than in the placebo group (p=0.008 for shade guide determination and p=0.000 for colorimeter determination). Conclusions There were no significant differences in in situ dentin fracture toughness results among the groups. The results of this study provide some reassurance that dentin is not overtly weakened by the bleaching protocol used in this study. However, the lack of a statistically significant difference cannot be used to state that there is no effect of bleach on dentin fracture toughness.


2013 ◽  
Vol 1 (1) ◽  
pp. 11 ◽  
Author(s):  
Fatema Yusuf ◽  
Savitha Adiga ◽  
Kusum Bashetty ◽  
Jayshree Hegde ◽  
Rupali Karale ◽  
...  

2008 ◽  
Vol 02 (03) ◽  
pp. 167-175 ◽  
Author(s):  
Abdulkadir Sengun ◽  
Hasan Orucoglu ◽  
Ilknur Ipekdal ◽  
Fusun Ozer

ABSTRACTObjectives: The purpose of this in vitro study was to evaluate whether mechanical alteration of the enamel surfaces with air abrasion and bur abrasion techniques could enhance the bonding performance of a three step and a self etching adhesive resin systems to enamel.Methods: 126 extracted lower human incisor teeth were used. The teeth were divided into three groups including 40 teeth each. First group; teeth were used as control and no preparation was made on enamel surfaces, 2nd group; outer enamel surfaces were air abraded, 3rd group; outer enamel surfaces were abraded mechanically with a diamond fissure bur. Cylinder composite resin blocks were bonded to the buccal enamel surfaces with two bonding systems (20 specimens in each group). Bond strengths to enamel surfaces were measured at a cross-head speed of 1 mm/min. The data were analyzed by ANOVA and Duncan Tests. To examine interface composite resin/enamel surfaces at scanning electron microscopy, remaining 6 teeth were used. Fracture analysis was performed using an optical stereomicroscope.Results: Bond strengths values of Solid Bond were significantly higher than bond strengths of Clearfil SE Bond for all types of enamel (P<.05). Shear bond strength values obtained with Solid Bond (three step system) to three types of enamel surfaces [air-abraded (30.25±7.00 MPa), bur-abraded (29.07±3.53 MPa), control (31.74±7.35 MPa)] were close to each other (P>.05). The macroscopic mode of failures for bonding systems, SB and SE Bond appeared to be adhesive and cohesive in nature.Conclusions: In order to get better bond strength values with self etching systems, it is advisable to prepare enamel surfaces with bur or air abrasion, but it enamel preparation is not necessary for three step systems. (Eur J Dent 2008;2:167-175)


2014 ◽  
Vol 113 (11) ◽  
pp. 850-856 ◽  
Author(s):  
Yin-Lin Wang ◽  
Chia-Chieh Chang ◽  
Chih-Wen Chi ◽  
Hao-Hueng Chang ◽  
Yu-Chih Chiang ◽  
...  

2018 ◽  
Vol 52 (3) ◽  
pp. 220-229 ◽  
Author(s):  
Qingru Jiang ◽  
Veera Kainulainen ◽  
Iva Stamatova ◽  
Riitta Korpela ◽  
Jukka H. Meurman

Probiotic administration may favour caries prevention, as recent research has shown. This in vitro study aimed to investigate the growth of Lactobacillus rhamnosus GG (LGG) in experimental biofilms exposed to various carbohydrates, and also to assess its cariogenic potential. Multispecies experimental oral biofilms with or without LGG were grown with a sole-carbohydrate source (fructose/glucose/lactose/sorbitol/sucrose). The viable cells of LGG and structure of the biofilms were examined after 64.5 h of incubation, and pH values of spent media were measured at 16.5, 40.5, and 64.5 h. Fermentation profiles of LGG in biofilm media were assessed with study carbohydrate as the sole energy source. Our results showed that LGG reached higher viable cell numbers with glucose and sucrose in 64.5-h multispecies experimental oral biofilms compared to other carbohydrates. When LGG was incorporated in biofilms, no distinct pH changes at any time points were observed under any of the carbohydrates used; the pH values of spent media at each time point were lower when lactose was used, compared to other carbohydrates. The fermentation profiles of LGG in biofilm media were similar to its growth in MRS (no obvious growth with lactose or sucrose). In conclusion, LGG in our in vitro multispecies experimental oral biofilms was capable of surviving and growing well in each carbohydrate source. LGG might not have harmful effects on dental hard tissues. Another finding from our study was that the lowest pH values were observed in the presence of lactose, and the thickest biofilms were in sucrose.


Sign in / Sign up

Export Citation Format

Share Document