Fiber Optic RealShape (FORS) Technology for Endovascular Navigation in Severe Tortuous Vessels

2022 ◽  
pp. 152660282110709
Author(s):  
Giuseppe Panuccio ◽  
Jose Torrealba ◽  
Fiona Rohlffs ◽  
Franziska Heidemann ◽  
Bart Wessels ◽  
...  

Purpose: The purpose of this study was to describe the use of a wire and catheters embedded with optical fiber (Fiber Optic RealShape [FORS]) to catheterize tortuous target vessels avoiding radiation. Technique: A virtual biplane vies was simulated coupling traditional x-ray system, preoperative CT scan, and FORS system to treat an isolated hypogastric aneurysm. Despite the complex anatomy, catheterization of all target vessels was possible in 12 minutes with 19 seconds of fluoroscopy time (Radiation Exposure 3.8 mGy×cm2). A minimal invasive endovascular exclusion of the aneurysm was achieved through selective coil-embolization of the iliolumbar artery and implantation of balloon expandable covered stents, thus preserving the perfusion of the superior gluteal artery. Conclusion: FORS guidance allowed catheterization of a target vessel with challenging anatomy with a low radiation exposure.

Author(s):  
P Kamusella ◽  
F Scheer ◽  
C Lüdtke ◽  
P Wiggermann ◽  
C Wissgott ◽  
...  
Keyword(s):  

2020 ◽  
Vol 3 ◽  
pp. 36-39
Author(s):  
Samson O. Paulinus ◽  
Benjamin E. Udoh ◽  
Bassey E. Archibong ◽  
Akpama E. Egong ◽  
Akwa E. Erim ◽  
...  

Objective: Physicians who often request for computed tomography (CT) scan examinations are expected to have sound knowledge of radiation exposure (risks) to patients in line with the basic radiation protection principles according to the International Commission on Radiological Protection (ICRP), the Protection of Persons Undergoing Medical Exposure or Treatment (POPUMET), and the Ionizing Radiation (Medical Exposure) Regulations (IR(ME)R). The aim is to assess the level of requesting physicians’ knowledge of ionizing radiation from CT scan examinations in two Nigerian tertiary hospitals. Materials and Methods: An 18-item-based questionnaire was distributed to 141 practicing medical doctors, excluding radiologists with work experience from 0 to >16 years in two major teaching hospitals in Nigeria with a return rate of 69%, using a voluntary sampling technique. Results: The results showed that 25% of the respondents identified CT thorax, abdomen, and pelvis examination as having the highest radiation risk, while 22% said that it was a conventional chest X-ray. Furthermore, 14% concluded that CT head had the highest risk while 9% gave their answer to be conventional abdominal X-ray. In addition, 17% inferred that magnetic resonance imaging had the highest radiation risk while 11% had no idea. Furthermore, 25.5% of the respondents have had training on ionizing radiation from CT scan examinations while 74.5% had no training. Majority (90%) of the respondents were not aware of the ICRP guidelines for requesting investigations with very little (<3%) or no knowledge (0%) on the POPUMET and the IR(ME)R respectively. Conclusion: There is low level of knowledge of ionizing radiation from CT scan examinations among requesting physicians in the study locations.


2019 ◽  
Vol 65 (5) ◽  
pp. 756-759
Author(s):  
Mikhail Postolov ◽  
Nadezhda Kovalenko ◽  
K. Babina ◽  
Stanislav Panin ◽  
Yelena Levchenko ◽  
...  

Perivascular epithelioid cell tumor (PEComa) is a rare mesenchymal neoplasm characterized by expression of both mela-nocytic and smooth muscle markers. Only 10 primary malignant lung PEComas have been reported up to date. We report a 59-year-old male who presented with a lung neoplasm, found during the routine X-ray examination. Preoperative CT-scan revealed the 3,5-cm-sized mass, located at the border of the upper, middle and lower lobes of the right lung. Patient underwent a thoracotomy, resection of the upper, middle and lower lobes of the right lung accompanied with mediastinal lymphadenectomy. After surgery, chylothorax was revealed. Conservative treatment was unsuccessful, so we performed laparoscopic clipping of the thoracic lymph duct. Patient was dismissed from hospital on the 10-th day after the second operation in good condition. In this report, we intend to increase the limited knowledge relating to natural history and optimal treatment of such a rare condition as a primary malignant lung PEComa.


2020 ◽  
Vol 11 (1) ◽  
pp. 301
Author(s):  
Sławomir Paśko ◽  
Wojciech Glinkowski

Scoliosis is a three-dimensional trunk and spinal deformity. Patient evaluation is essential for the decision-making process and determines the selection of specific and adequate treatment. The diagnosis requires a radiological evaluation that exposes patients to radiation. This exposure reaches hazardous levels when numerous, repetitive radiographic studies are required for diagnostics, monitoring, and treatment. Technological improvements in radiographic devices have significantly reduced radiation exposure, but the risk for patients remains. Optical three-dimensional surface topography (3D ST) measurement systems that use surface topography (ST) to screen, diagnose, and monitor scoliosis are safer alternatives to radiography. The study aimed to show that the combination of plain X-ray and 3D ST scans allows for an approximate presentation of the vertebral column spinous processes line in space to determine the shape of the spine’s deformity in scoliosis patients. Twelve patients diagnosed with scoliosis, aged 13.1 ± 4.5 years (range: 9 to 20 years) (mean: Cobb angle 17.8°, SD: ±9.5°) were enrolled in the study. Patients were diagnosed using full-spine X-ray and whole torso 3D ST. The novel three-dimensional assessment of the spinous process lines by merging 3D ST and X-ray data in patients with scoliosis was implemented. The method’s expected uncertainty is less than 5 mm, which is better than the norm for a standard measurement tool. The presented accuracy level is considered adequate; the proposed solution is accurate enough to monitor the changes in the shape of scoliosis’s spinous processes line. The proposed method allows for a relatively precise calculation of the spinous process lines based on a three-dimensional point cloud obtained with a four-directional, three-dimensional structured light diagnostic system and a single X-ray image. The method may help reduce patients’ total radiation exposure and avoid one X-ray in the sagittal projection if biplanar radiograms are required for reconstructing the three-dimensional line of the spinous processes line.


1975 ◽  
Vol 14 (7) ◽  
pp. 1484 ◽  
Author(s):  
Clayton W. Bates ◽  
Stephen D. Sparks
Keyword(s):  

2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Lian Wang ◽  
Juncheng Zhou ◽  
Yuhao Chen ◽  
Liu Xiao ◽  
Guojia Huang ◽  
...  

Abstract An intensity modulated fiber-optic carbon monoxide (CO) sensor by integrating in-situ solvothermal-growth Ag/Co-MOF sensing film is fabricated and evaluated. The Michelson interference sensing structure is composed of single-mode fiber (SMF), enlarged taper, thin-core fiber (TCF), and Ag film as the reflector. Ag/Co-MOF was coated on the cladding of the TCF as the sensing material, and the enlarged taper is located between TCF and SMF as the coupler. The structure, morphology, compositions and thermal stability of the Ag/Co-MOF sensing film were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS), thermogravimetric analysis (TGA), etc. The sensitivity of the sensor is 0.04515 dB/ppm, and the fitting parameter of the CO concentration is 0.99876. In addition, the sensor has the advantages of good selectivity, good signal and temperature stability, and it has potential application in trace CO detection.


Circulation ◽  
2007 ◽  
Vol 116 (suppl_16) ◽  
Author(s):  
Carlos A Van Mieghem ◽  
Annick C Weustink ◽  
Marcel Kofflard ◽  
A. Schreve-Steensma ◽  
Niels A Matheijssen ◽  
...  

Introduction and aim: Dual Source CT (DSCT) scanners, with an increased temporal resolution (83 ms), are becoming widely available. To evaluate the current potential of this scanner in the clinical arena, we performed a head-to-head comparison with conventional coronary angiography (CCA) taking into account the following parameters: radiation exposure, procedure time and contrast load. Methods: During a one-year period (april 2006 to march 2007) we compared a consecutive patient group who underwent DSCT (318 patients, 222 male, mean age 68±11 years) and CCA (352 patients, 258 male, mean age 61±12) respectively. Patients with previous bypass surgery were excluded. In DSCT, the volume of iodinated contrast material was adapted to the scan time. A contrast bolus was injected in an antecubital vein at a flow rate of 5.0 ml/s followed by a saline chaser of 40 ml at 5.0 ml/s. Each tube provided 412 mAs/rot (maximum), and full X-ray tube current was given during 25–70% of the RR-interval. Exposure data were collected using the x-ray dosimetrical reports from DSCT and CCA. Results: The mean procedure time using DSCT and CCA was 16.1±4.7 min and 44.1±25.5 min (p<0.001), respectively. The mean contrast load in DSCT and CCA was 77.9±7.6 ml and 175.3±4.3ml (p<0.001), respectively. The overall radiation exposure for DSCT and CCA was calculated as 15.3±4.0 mSv and 5.7±4.3 mSv, respectively. Radiation exposure with DSCT was significantly lower (p<0.001) in patients with a heart rate of >70 bpm (12.9±3.1 mSv ) as compared with patients with heart rates <70 bpm (16.4±3.8 mSv). Conclusion: In today’s practice currently available DSCT scanners perform favorably as compared with CCA, considering procedure time and patient contrast load. Radiation exposure with DSCT remains higher but should not be considered a major disadvantage taking into account the relatively old age group that generally undergoes coronary angiography and the major benefit of not being exposed to the risks of an invasive procedure.


2011 ◽  
Vol 15 (3) ◽  
pp. 70 ◽  
Author(s):  
Geoffrey K Korir ◽  
Jeska Sidika Wambani ◽  
Ian K Korir

Background. The wide use of ionising radiation in medical care has resulted in the largest man-made cause of radiation exposure. In recent years, diagnostic departments in Kenya have adapted the high-speed film/screen combination without well-established quality control, objective image quality criteria, and assessment of patient dose. The safety of patients in terms of justification and the as-low-as-reasonably-achievable (ALARA) principle is inadequate without quality assurance measures. Aim. This study assessed the level of film rejects, device performance, image quality and patient dose in 4 representative hospitals using high-speed film/screen combination. Results. The X-ray equipment quality control tests performance range was 67% to 90%, and 63% of the radiographs were of good diagnostic value. The measured prevalent chest examination entrance surface dose (ESD) showed levels above the international diagnostic reference levels (DRLs), while lumbar spine and pelvis examination was the largest source of radiation exposure to patients. Conclusion. The optimisation of patient protection can be achieved with optimally performing X-ray equipment, the application of good radiographic technique, and continuous assessment of radiographic image quality.


2017 ◽  
Vol 75 (3) ◽  
pp. 199-204 ◽  
Author(s):  
Lucie Fournier ◽  
Enora Cléro ◽  
Eric Samson ◽  
Sylvaine Caër-Lorho ◽  
Dominique Laurier ◽  
...  

ObjectivesThe French nuclear worker cohort allows for the assessment of cancer risk associated with occupational radiation exposure, but workers are also exposed to medical and environmental radiation which can be of the same order of magnitude. This study aims to examine the impact of non-occupational radiation exposures on the dose-risk analysis between occupational radiation exposure and cancer mortality.MethodsThe cohort included workers employed before 1995 for at least one year by CEA, AREVA NC or EDF and badge-monitored for external radiation exposure. Monitoring results were used to calculate occupational individual doses. Scenarios of work-related X-ray and environmental exposures were simulated. Poisson regression was used to quantify associations between occupational exposure and cancer mortality adjusting for non-occupational radiation exposure.ResultsThe mean cumulative dose of external occupational radiation was 18.4 mSv among 59 004 workers. Depending on the hypotheses made, the mean cumulative work-related X-ray dose varied between 3.1 and 9.2 mSv and the mean cumulative environmental dose was around 130 mSv. The unadjusted excess relative rate of cancer per Sievert (ERR/Sv) was 0.34 (90% CI −0.44 to 1.24). Adjusting for environmental radiation exposure did not substantially modify this risk coefficient, but it was attenuated by medical exposure (ERR/Sv point estimate between 0.15 and 0.23).ConclusionsOccupational radiation risk estimates were lower when adjusted for work-related X-ray exposures. Environmental exposures had a very slight impact on the occupational exposure risk estimates. In any scenario of non-occupational exposure considered, a positive but insignificant excess cancer risk associated with occupational exposure was observed.


Sign in / Sign up

Export Citation Format

Share Document