Thermal protective performance of single-layer rib-knitted structure and its derivatives under radiant heat flux

2021 ◽  
pp. 152808372110426
Author(s):  
Sandeep K Maurya ◽  
Viraj Uttamrao Somkuwar ◽  
Hema Garg ◽  
Apurba Das ◽  
Bipin Kumar

The compact construction of fire-resistant woven clothing designed for radiant heat flux protection limits the air permeability from the skin to the environment that risks thermal stress to the wearer. Knitted fabric is well known for its comfort and transmission properties. The inevitable porosity of the knitted fabric has restrained its application in fire-protective clothing. This study attempts to apply tuck and miss elements of a knitted structure to produce a compact yet comfortable flame-retardant fabric with maximum air permeability. The effect of radiant heat exposure at the intensity of 40 kW/m2 and 61 kW/m2 is analyzed for the designed sample. The tuck and miss stitches are used to modify rib-knitted structure and the second-degree burn time estimated using Stoll’s curve. The findings of this research show that a simple modification of rib structure with incorporation of miss stitch can enhance the second-degree burn time to 30 s at the radiant heat exposure of 40 kW/m2.

2016 ◽  
Vol 47 (5) ◽  
pp. 853-869 ◽  
Author(s):  
Yun Su ◽  
Jun Li

Protection from steam burns is beneficial to reduce the nonfatal injuries of firefighters in firefighting and rescue operations. A new multifunctional testing apparatus was employed to study heat and steam transfer in protective clothing under low-pressure steam and low-level thermal radiation. Single-, double-, and triple-layered fabric assemblies were selected in this experiment. It is indicated that the existence of hot steam weakens the positive influence of the fabric’s thickness, but increases the importance of the air permeability on the thermal protection. The fabric assemblies entrapping moisture barrier can better resist the penetration of steam through the fabric system, and significantly improve the thermal protection in low steam and thermal radiation exposure due to the low air permeability. Additionally, the total transmitted energy ( Qe) and dry thermal energy ( Qd) under low steam and thermal radiation are dramatically larger than that under thermal radiation ( p < 0.05), while hot steam insignificantly reduces the thermal energy during the cooling ( p = 0.143 > 0.05). The understanding of steam heat transfer helps to provide proper guidance to improve the thermal protection of the firefighter’s clothing and reduce steam burns.


Author(s):  
В.К. Абгарян ◽  
М.В. Абгарян ◽  
А.Б. Надирадзе ◽  
В.В. Нигматзянов ◽  
А.А. Семенов

The radiant heat flux coming from the discharge plasma on the surfaces of radio frequency ion thrusters is considered. Spontaneous emission of photons is formed when the excitation of plasma atoms and ions is removed. The distributions of the densities of the heat flux brought by radiation to the surface in the thrusters are calculated. The distributions can be used in numerical calculations of temperatures in thrusters design.


2017 ◽  
Vol 21 (4) ◽  
pp. 1665-1671 ◽  
Author(s):  
Meng Chen ◽  
Fanglong Zhu ◽  
Qianqian Feng ◽  
Kejing Li ◽  
Rangtong Liu

The effects of absorbed moisture on thermal protective performance of fire-fighters? clothing materials under radiant heat flux conditions were analyzed in this paper. A thermal protective performance tester and temperature sensor were used to measure the temperature variations for the facecloth side of four kinds of commonly used flame retardant fabrics in several radiant heat exposures, which varied in moisture content. Experimental results showed that, all of the temperature profiles of these four kinds of moistened fabrics under different radiant heat flux conditions presented the same variation trend. The addition of moisture had a positive influence on the thermal protective performance during the constant temperature period when heat radiation time was more than 60 seconds. As the heat radiation time increased beyond 500 seconds, the thermal protective performance of moistened fabrics became worse than that of dried fabrics in general.


2021 ◽  
pp. 073490412110366
Author(s):  
Junhui Gong ◽  
Hongen Zhou ◽  
Hong Zhu ◽  
Conor G McCoy ◽  
Stanislav I Stoliarov

Oriented strand board is a widely used construction material responsible for a substantial portion of the fire load of many buildings. To accurately model oriented strand board fire response, kinetics and thermodynamics of its thermal decomposition and combustion were carefully characterized using milligram-scale testing in part I of this study. In the current work, Controlled Atmosphere Pyrolysis Apparatus II tests were performed on representative gram-sized oriented strand board samples at a range of radiant heat fluxes. An automated inverse analysis of the sample temperature data obtained in these tests was employed to determine the thermal conductivities of the undecomposed oriented strand board and condensed-phase products of its decomposition. A complete pyrolysis model was formulated for this material and used to predict the mass loss rates measured in the Controlled Atmosphere Pyrolysis Apparatus II experiments. These mass loss rate profiles were predicted well with the exception of the second mass loss rate peak observed at 65 kW m−2 of radiant heat flux, which was underpredicted. To further validate the model, cone calorimeter tests were performed on oriented strand board at 25 and 50 kW m−2 of radiant heat flux. The results of these tests, including both mass loss rate and heat release rate profiles, were predicted reasonably well by the model.


2020 ◽  
Vol 175 ◽  
pp. 62-80 ◽  
Author(s):  
James E. Hilton ◽  
Justin E. Leonard ◽  
Raphaele Blanchi ◽  
Glenn J. Newnham ◽  
Kimberley Opie ◽  
...  

Author(s):  
A Chen ◽  
J Francis

Current practice when predicting safe separation distances between buildings is to assess the radiant hazard posed by flames and hot gas visible across the vent. The vent is treated as a radiating vertical surface with a representative temperature. A method is proposed for calculating the radiant heat flux to external surfaces from hot gas and extrusive flame emerging from a vent in a compartment wall containing post-flashover fire. An experimental study has been made to examine the validity of the method for extrusive flames unaffected by wind.


Sign in / Sign up

Export Citation Format

Share Document