scholarly journals The reliability and validity of goniometric elbow measurements in adults: A systematic review of the literature

2018 ◽  
Vol 10 (4) ◽  
pp. 274-284 ◽  
Author(s):  
Suzanne F van Rijn ◽  
Elisa L Zwerus ◽  
Koen LM Koenraadt ◽  
Wilco CH Jacobs ◽  
Michel PJ van den Bekerom ◽  
...  

Background The universal goniometer is a simple measuring tool. With this review we aimed to investigate the reliability and validity of the universal goniometer in measurements of the adults' elbow. Methods Preferred Reporting Items for Systematic reviews and Meta-Analysis guidelines were followed and our study protocol was published online at PROSPERO. A literature search was conducted on relevant studies. Methodological quality was assessed using the Quality Appraisal of Diagnostic Reliability (QAREL) scoring system. Results Out of 697 studies yielded from our literature search, 12 were included. Six studies were rated as high quality. The intrarater reliability intraclass correlation coefficient ranged from 0.45 to 0.99, the interrater reliability ranged from intraclass correlation coefficient 0.53–0.97. One study providing instructions on goniometric alignment did not find a difference in expert versus non-expert examiners. Another study in which examiners were not instructed found a higher interrater reliability in expert examiners. One study investigating the validity of the goniometer in elbow measurements found a maximum standard error of the mean of 11.5° for total range of motion. Discussion Overall, the studies showed high intra- and interrater reliability of the universal goniometer. The reliability of the universal goniometer in non-expert examiners can be increased by clear instructions on goniometric alignment.

2017 ◽  
Vol 52 (9) ◽  
pp. 826-833 ◽  
Author(s):  
James L. Farnsworth ◽  
Lucas Dargo ◽  
Brian G. Ragan ◽  
Minsoo Kang

Objective:  Although widely used, computerized neurocognitive tests (CNTs) have been criticized because of low reliability and poor sensitivity. A systematic review was published summarizing the reliability of Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) scores; however, this was limited to a single CNT. Expansion of the previous review to include additional CNTs and a meta-analysis is needed. Therefore, our purpose was to analyze reliability data for CNTs using meta-analysis and examine moderating factors that may influence reliability. Data Sources:  A systematic literature search (key terms: reliability, computerized neurocognitive test, concussion) of electronic databases (MEDLINE, PubMed, Google Scholar, and SPORTDiscus) was conducted to identify relevant studies. Study Selection:  Studies were included if they met all of the following criteria: used a test-retest design, involved at least 1 CNT, provided sufficient statistical data to allow for effect-size calculation, and were published in English. Data Extraction:  Two independent reviewers investigated each article to assess inclusion criteria. Eighteen studies involving 2674 participants were retained. Intraclass correlation coefficients were extracted to calculate effect sizes and determine overall reliability. The Fisher Z transformation adjusted for sampling error associated with averaging correlations. Moderator analyses were conducted to evaluate the effects of the length of the test-retest interval, intraclass correlation coefficient model selection, participant demographics, and study design on reliability. Heterogeneity was evaluated using the Cochran Q statistic. Data Synthesis:  The proportion of acceptable outcomes was greatest for the Axon Sports CogState Test (75%) and lowest for the ImPACT (25%). Moderator analyses indicated that the type of intraclass correlation coefficient model used significantly influenced effect-size estimates, accounting for 17% of the variation in reliability. Conclusions:  The Axon Sports CogState Test, which has a higher proportion of acceptable outcomes and shorter test duration relative to other CNTs, may be a reliable option; however, future studies are needed to compare the diagnostic accuracy of these instruments.


2021 ◽  
Vol 104 (11) ◽  
pp. 1784-1787

Objective: To evaluate the reliability and validity of the Thai version of the Carolinas Comfort Scale (CCS) to measure health-related quality of life (HRQoL) in post-hernia repaired patients. Materials and Methods: Three hundred twenty-eight patients that underwent the inguinal hernia repair procedure in Vajira Hospital were recruited in the present study. The Thai version of CCS (TCCS) was performed entirely by the patient, and the test-retest reliability was conducted at a 2-week interval. Results: The TCCS’s internal consistency reliability was excellent (Cronbach’s alpha 0.89). The inter-rater reliability was found to agree with the intraclass correlation coefficient of 0.90. The test-retest reliability over two weeks was high, with an intraclass correlation coefficient of 0.92. Conclusion: The Thai version of CCS was found to have adequate reliability and validity and could be used to measure HRQoL in Thai patients that undergo inguinal hernia repair. Keywords: Reliability; Validity; Carolinas Comfort Scale; Thai version


2020 ◽  
Vol 2020 ◽  
pp. 1-8
Author(s):  
Jiali Lou ◽  
Yongliang Jiang ◽  
Hantong Hu ◽  
Xiaoyu Li ◽  
Yajun Zhang ◽  
...  

The objective of this study was to determine the intrarater and interrater reliabilities of infrared image analysis of forearm acupoints before and after moxibustion. In this work, infrared images of acupoints in the forearm of 20 volunteers (M/F, 10/10) were collected prior to and after moxibustion by infrared thermography (IRT). Two trained raters performed the analysis of infrared images in two different periods at a one-week interval. The intraclass correlation coefficient (ICC) was calculated to determine the intrarater and interrater reliabilities. With regard to the intrarater reliability, ICC values were between 0.758 and 0.994 (substantial to excellent). For the interrater reliability, ICC values ranged from 0.707 to 0.964 (moderate to excellent). Given that the intrarater and interrater reliability levels show excellent concordance, IRT could be a reliable tool to monitor the temperature change of forearm acupoints induced by moxibustion.


1998 ◽  
Vol 18 (4) ◽  
pp. 193-206 ◽  
Author(s):  
Lena Haglund ◽  
Lars-Hakan Thorell ◽  
Jan Walinder

A Swedish version of the Occupational Case Analysis Interview and Rating Scale (OCAIRS-S) has been tested earlier for interrater reliability. The present study, using the second version of OCAIRS-S and including a sample of 145 patients, showed interrater correlations between .88 and .96 (Intraclass Correlation Coefficient). The results indicate that OCAIRS-S predicts which patients should be included in and excluded from occupational therapy and identifies patients who should be observed more before making such decisions. The study indicates a need for further investigations regarding which components in OCAIRS-S influence the occupational therapist in judging the patient's need for occupational therapy.


2017 ◽  
Vol 48 (01) ◽  
pp. 24-38 ◽  
Author(s):  
Courtney Ryder ◽  
Tamara Mackean ◽  
Shahid Ullah ◽  
Heather Burton ◽  
Heather Halls ◽  
...  

Socially accountable health curricula, designed to decrease Aboriginal health inequities through the transformation of health professional students into culturally safe practitioners, has become a focal point for health professional programmes. Despite this inclusion in health curricula there remains the question of how to best assess students in this area in relation to the concept, of cultural safety and transformative unlearning, to facilitate attitudinal change. To address this question, this study developed a research questionnaire to measure thematic areas of transformative unlearning, cultural safety and critical thinking in Aboriginal Health for application on undergraduate and postgraduate students and faculty staff. The Likert-scale questionnaire was developed and validated through face and content validity. Test–retest methodology was utilised to determine stability and reliability of the questionnaire with 40 participants. The extent of agreement and reliability were determined through weighted kappa and intraclass correlation coefficient. Exploratory factor analysis was calculated to determine construct validity for questionnaire items. For the overall population subset the tool met good standards of reliability and validity, with 11 of the 15 items reaching moderate agreement (κ > 0.6) and an intraclass correlation coefficient of 0.72, suggesting substantial agreement. Cronbach's alpha was calculated above 0.7 for the thematic areas. The majority of items provided high factor loadings, low loading items will be reviewed to strengthen the tool, where validations of the revised tool with a larger cohort will allow future use to compare and determine effective teaching methodologies in Aboriginal health and cultural safety curricula.


2001 ◽  
Vol 94 (6) ◽  
pp. 958-962 ◽  
Author(s):  
Stephen H. Halpern ◽  
Judith A. Littleford ◽  
Nicole J. Brockhurst ◽  
Paul J. Youngs ◽  
Nariman Malik ◽  
...  

Background The Neurologic and Adaptive Capacity Score (NACS) is a multi-item scale that was published in 1982 to measure the effects of intrapartum drugs on the neonate. Although this scoring system has been widely used in obstetric anesthesia research, studies confirming its reliability have not been published. The purpose of this study was to assess the reliability of the NACS. Methods Two teams of observers were trained to perform the NACS on healthy, term neonates born in the vertex presentation. Two examinations were performed on each neonate within the first 2.5 h of life. Simultaneous (or "split-half") reliability was assessed using the alpha coefficient. Test-retest reliability was assessed using the intraclass correlation coefficient. The test was considered to be reliable if a was greater than 0.7 and the intraclass correlation coefficient was greater than 0.6. Results Two hundred babies were studied. The a was 0.47 and the intraclass correlation coefficient was 0.38 (95% confidence interval, 0.24-0.52). Conclusions The NACS had poor reliability both on simultaneous testing and in the test-retest situation when used to evaluate term, healthy neonates. The authors suggest that other measures need to be developed to evaluate the effect of intrapartum drug administration in the neonate. Health measurement scales should undergo rigorous assessment for reliability and validity before they are used in clinical practice or for research purposes.


2014 ◽  
Vol 49 (5) ◽  
pp. 640-646 ◽  
Author(s):  
Mark A. Kevern ◽  
Michael Beecher ◽  
Smita Rao

Context: Athletes who participate in throwing and racket sports consistently demonstrate adaptive changes in glenohumeral-joint internal and external rotation in the dominant arm. Measurements of these motions have demonstrated excellent intrarater and poor interrater reliability. Objective: To determine intrarater reliability, interrater reliability, and standard error of measurement for shoulder internal rotation, external rotation, and total arc of motion using an inclinometer in 3 testing procedures in National Collegiate Athletic Association Division I baseball and softball athletes. Design: Cross-sectional study. Setting: Athletic department. Patients or Other Participants Thirty-eight players participated in the study. Shoulder internal rotation, external rotation, and total arc of motion were measured by 2 investigators in 3 test positions. The standard supine position was compared with a side-lying test position, as well as a supine test position without examiner overpressure. Results: Excellent intrarater reliability was noted for all 3 test positions and ranges of motion, with intraclass correlation coefficient values ranging from 0.93 to 0.99. Results for interrater reliability were less favorable. Reliability for internal rotation was highest in the side-lying position (0.68) and reliability for external rotation and total arc was highest in the supine-without-overpressure position (0.774 and 0.713, respectively). The supine-with-overpressure position yielded the lowest interrater reliability results in all positions. The side-lying position had the most consistent results, with very little variation among intraclass correlation coefficient values for the various test positions. Conclusions: The results of our study clearly indicate that the side-lying test procedure is of equal or greater value than the traditional supine-with-overpressure method.


2020 ◽  
Vol 28 (3) ◽  
pp. 455-466 ◽  
Author(s):  
Jennifer J. Sherwood ◽  
Cathy Inouye ◽  
Shannon L. Webb ◽  
Jenny O

The study aims were to analyze the reliability and validity of the GymAware™ linear position transducer’s velocity and power measures during the sit-to-stand, compared with the Dartfish 2D videography analysis, and to assess the relationship of age and handgrip strength with velocity and power in 48 older men and women (77.6 ± 11.1 years). The results showed excellent agreement between GymAware- and Dartfish-derived sit-to-stand velocity (intraclass correlation coefficient2-1 = .94 and power intraclass correlation coefficient2-1 = .98) measures. A moderate and negative relationship was found between age and velocity (r = −.62; p < .001) and age and power (r = −.63; p < .001). A moderate and positive relationship was found between handgrip strength and velocity (r = .43; p = .002) and handgrip strength and power (r = .54; p < .001). The results show the GymAware velocity and power measures during the sit-to-stand in older adults to be reliable and valid.


2019 ◽  
Vol 16 (11) ◽  
pp. 962-967
Author(s):  
Esra Uzelpasaci ◽  
Türkan Akbayrak ◽  
Serap Özgül ◽  
Ceren Orhan ◽  
Emine Baran ◽  
...  

Background: Evaluation of physical activity by condition-specific surveys provides more accurate results than generic physical activity questionnaires. The aim of this study was to investigate the reliability and validity of the Kaiser Physical Activity Survey (KPAS) in Turkish pregnant women. Methods: In the translation and cultural adaptation of the KPAS, the 6-phase guidelines recommended in the literature were followed. The study included a total of 151 pregnant women who were assessed using the Turkish version of KPAS, the Pregnancy Physical Activity Questionnaire, and the SenseWear Pro3 Armband. To determine the test–retest reliability, the KPAS was reapplied after 7 days. The psychometric properties of KPAS were analyzed with respect to internal consistency, test–retest reliability, and concurrent validity. Results: Cronbach α coefficient indicating the internal consistency of the Turkish KPAS was found to be .60 to .80, showing moderate reliability. The intraclass correlation coefficient for test–retest reliability was very strong (intraclass correlation coefficient: .96–.98). The total KPAS scores were found to be moderately correlated with the total Pregnancy Physical Activity Questionnaire score and the total energy expenditure value on the SenseWear Pro3 Armband. Conclusions: This study showed that KPAS is a valid and reliable instrument for evaluating physical activity in Turkish pregnant women in different aspects.