scholarly journals Challenges to Glycemic Measurement in the Perioperative and Critically Ill Patient: A Review

2009 ◽  
Vol 3 (6) ◽  
pp. 1270-1281 ◽  
Author(s):  
Andrew D. Pitkin ◽  
Mark J. Rice

Accurate monitoring of glucose in the perioperative environment has become increasingly important over the last few years. Because of increased cost, turnaround time, and sample volume, the use of central laboratory devices for glucose measurement has been somewhat supplanted by point-of-care (POC) glucose devices. The trade-off in moving to these POC systems has been a reduction in accuracy, especially in the hypoglycemic range. Furthermore, many of these POC devices were originally developed, marketed, and received Food and Drug Administration regulatory clearance as home use devices for patients with diabetes. Without further review, many of these POC glucose measurement devices have found their way into the hospital environment and are used frequently for measurement during intense insulin therapy, where accurate measurements are critical. This review covers the technology behind glucose measurement and the evidence questioning the use of many POC devices for perioperative glucose management.

2019 ◽  
Vol 12 (1) ◽  
pp. 342-368
Author(s):  
Federica Pezzuto ◽  
Antonio Scarano ◽  
Carlotta Marini ◽  
Giacomo Rossi ◽  
Roberta Stocchi ◽  
...  

a Updated and precise molecular diagnostics are essential in disease identification, treatment and management. Conventional technologies are limited to laboratories, which are expensive, require moderate to great volumes of biological fluids and generally create great discomfort among patients. This review discusses some key features of commercially available point of care (POC) devices, such as time to provide results, accuracy and imprecision, in several medical and veterinary fields. We searched Pubmed/Medline using the keywords “point” “of” “care” “device”, selected papers from 1984 to 2019 on the basis of their content and summarized the features in tables. Fast turnaround time and overall good reliability, in terms of accuracy and imprecision, were observed for most of POCs included in the research. POC devices are particularly useful for clinicians since they hold the potential to deliver rapid and accurate results in an inexpensive and less invasive way with an overall improvement of patients' quality of life in terms of time spent at the point-of-care and sample volume withdrawn. These features gain great relevance also in the veterinary practice, where patients’ compliance is generally poor, available sample volumes are quite far from the human ones and analysis costs are higher.


Author(s):  
Dami Collier ◽  
Sonny M. Assennato ◽  
Ben Warne ◽  
Nyarie Sithole ◽  
Katherine Sharrocks ◽  
...  

AbstractBackgroundThere is urgent need for safe and efficient triage protocols for hospitalized COVID-19 suspects to appropriate isolation wards. A major barrier to timely discharge of patients from the emergency room and hospital is the turnaround time for many SARS-CoV-2 nucleic acid tests. We validated a point of care nucleic acid amplification based platform SAMBA II for diagnosis of COVID-19 and performed an implementation study to assess its impact on patient disposition at a major academic hospital.MethodsWe prospectively recruited COVID-19 suspects admitted to hospital (NCT04326387). In an initial pilot phase, individuals were tested using a nasal/throat swab with the SAMBA II SARS-CoV-2 rapid diagnostic platform in parallel with a combined nasal/throat swab for standard central laboratory RT-PCR testing. In the second implementation phase, we examined the utility of adding the SAMBA platform to routine care. In the pilot phase, we measured concordance and assay validity using the central laboratory as the reference standard and assessed assay turnaround time. In the implementation phase, we assessed 1) time to definitive bed placement from admission, 2) time spent on COVID-19 holding wards, 3) proportion of patients in isolation versus COVID negative areas following a test, comparing the implementation phase with the 10 days prior to implementation.ResultsIn phase I, 149 participants were included in the pilot. By central laboratory RT-PCR testing, 32 (21.5%) tested positive and 117 (78.5%). Sensitivity and specificity of the SAMBA assay compared to RT-PCR lab test were 96.9% (95% CI 0.838-0.999) and 99.1% (0.953-0.999), respectively. Median time to result was 2.6 hours (IQR 2.3 to 4.8) for SAMBA II SARS-CoV-2 test and 26.4 hours (IQR 21.4 to 31.4) for the standard lab RT-PCR test (p<0.001). In the first 10 days of the SAMBA implementation phase, we conducted 992 tests, with the majority (59.8%) used for hospital admission, and the remainder for pre-operative screening (11.3%), discharge planning (10%), in-hospital screening of new symptoms (9.7%). Comparing the pre-implementation (n=599) with the implementation phase, median time to definitive bed placement from admission was reduced from 23.4 hours (8.6-41.9) to 17.1 hours (9.0-28.8), P=0.02 in Cox analysis, adjusted for age, sex, comorbidities and clinical severity at presentation. Mean length of stay on a COVID-19 ‘holding’ ward decreased from 58.5 hours to 29.9 hours (P<0.001). Use of single occupancy rooms amongst those tested fell from 30.8% before to 21.2% (P=0.03) and 11 hospital bay closures (on average 6 beds each) were avoided after implementation of the POC assay.ConclusionsThe SAMBA II SARS-CoV-2 rapid assay performed well compared to a centralized laboratory RT-PCR platform and demonstrated shorter time to result both in trial and real-world settings. It was also associated with faster time to definitive bed placement from the emergency room, greater availability of isolation rooms, avoidance of hospital bay closures, and greater movement of patients to COVID negative open “green” category wards. Rapid testing in hospitals has the potential to transform ability to deal with the COVID-19 epidemic.


Author(s):  
Miguel Cantero ◽  
Maximino Redondo ◽  
Eva Martín ◽  
Gonzalo Callejón ◽  
María Luisa Hortas

AbstractPoint-of-care testing (POCT), like other laboratory tests, can be affected by errors throughout the total testing process. To evaluate quality error rates, the use of quality indicators (QIs) is recommended; however, little information is available on the quality error rate associated with POCT. The objective of this study was to investigate quality error rates related to POCT and compare them with central laboratory (CL) testing.We studied standardized QIs for POCT in comparison to CL testing. We compared error rates related to requests, collection, and handling of samples and results from external quality assessment program (EQAP) and internal quality control (IQC).The highest difference between POCT and CL testing was observed for QI related to patient identification, 45.3% vs. 0.02% (p<0.001). Regarding specimen collection and handling, the QI related to samples without results was also higher in POCT than in CL testing, 15.8% vs. 3.3% (p<0.001). For the QI related to insufficient sample volume, we obtained 2.9% vs. 0.9% (p=0.27). Unlike QIs for the preanalytical phase, QIs for the analytical phase had better results in POCT than CL testing. We obtained 8.3% vs. 16.6% (p=0.13) for QI related to unacceptable results in EQAP and 0.8% vs. 22.5% (p<0.001) for QI related to unacceptable results in IQC.Our results show that the preanalytical phase remains the main problem in POCT like in CL testing and that monitoring of quality indicators is a very valuable tool in reducing errors in POCT.


2009 ◽  
Vol 101 (02) ◽  
pp. 394-401 ◽  
Author(s):  
Yves Ozier ◽  
Annick Ankri ◽  
Marie-Hélène Fléron ◽  
Geneviève Leroux ◽  
Charles Marc Samama ◽  
...  

SummaryDelay in collecting coagulation test results from a central laboratory is one of the critical issues to efficiently control haemostasis during surgery. The aim of this multicenter study was to compare the performance of a point-of-care (POC) device (CoaguChek™ Pro DM) with the central laboratory-based coagulation testing during haemorrhagic surgery. For this purpose, 93 patients undergoing major surgical procedure were prospectively included in three centers. Blood was drawn from all patients before surgical incision and from most patients during surgical procedure after a blood loss of 25% or more was observed. When expressed in activity percentage, POC-based prothrombin time (PT) was in good agreement with central laboratory test result with coefficient of correlation in the range from 0.711 to 0.960 in the three centers. Comparison was less conclusive when PT was expressed in seconds or as the patient-to-control ratio and for activated partial thromboplastin time, with significantly shorter clotting times and lower ratios obtained on the POC device. On-site PT (in activity percentage) monitoring would have induced no significant change in fresh frozen plasma (FFP) transfusion in patients when compared to central laboratory monitoring. Test results were obtained in less than 5 minutes when performed using the POC device versus a median turnaround time of 88 minutes (range: 29–235 minutes) when blood collection tubes were sent to the central laboratory. These results suggest that, in providing a rapid answer, POC-based monitoring of PT (in percentage) using the CoaguChek device could be validly used in patients undergoing haemorrhagic surgical procedures.


Author(s):  
Francesca Di Serio ◽  
Gianfranco Amodio ◽  
Lucia Varraso ◽  
Maurizio Campaniello ◽  
Paola Coluccia ◽  
...  

AbstractTo achieve rapid assessment of chest pain in emergency/cardiology departments, a short turnaround time for cardiac marker testing is necessary. Nevertheless, Total Quality Management principles must be incorporated into the management of point-of-care testing (POCT); in this setting we implemented the Stratus CS


Diagnosis ◽  
2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Camilla Mattiuzzi ◽  
Brandon M. Henry ◽  
Giuseppe Lippi

AbstractAlthough the most effective strategy for preventing or containing severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) outbreaks relies on early diagnosis, the paramount and unprecedented number of tests needed to fully achieve this target is overwhelming worldwide testing supply and capacity. Molecular detection of SARS-CoV-2 RNA in nasopharyngeal swabs is still considered the reference diagnostic approach. Nonetheless, identification of SARS-CoV-2 proteins in upper respiratory tract specimens and/or saliva by means of rapid (antigen) immunoassays is emerging as a promising screening approach. These tests have some advantages compared to molecular analysis, such as point of care availability, no need of skilled personnel and dedicated instrumentation, lower costs and short turnaround time. However, these advantages are counterbalanced by lower diagnostic sensitivity compared to molecular testing, which would only enable to identifying patients with higher SARS-CoV-2 viral load. The evidence accumulated to-date has hence persuaded us to develop a tentative algorithm, which would magnify the potential benefits of rapid antigen testing in SARS-CoV-2 diagnostics.


2021 ◽  
pp. 104063872110018
Author(s):  
Justin R. Perrault ◽  
Michael D. Arendt ◽  
Jeffrey A. Schwenter ◽  
Julia L. Byrd ◽  
Kathryn A. Tuxbury ◽  
...  

Blood glucose measurements provide important diagnostic information regarding stress, disease, and nutritional status. Glucose analytical methodologies include dry chemistry analysis (DCA) of plasma and point-of-care (POC) glucometer analysis of whole blood; however, these 2 methods differ in cost, required sample volume, and processing time. Because POC glucometers use built-in equations based on features of mammalian blood to convert whole blood measurements to plasma equivalent units, obtained glucose data must be compared and validated using gold-standard chemistry analytical methodology in reptiles. For in-water, trawl-captured, immature Kemp’s ridley sea turtles ( Lepidochelys kempii) from Georgia, USA, we observed significant, positive agreement between the 2 glucose determination methods; however, the glucometer overestimated glucose concentrations by 1.4 mmol/L on average in comparison to DCA and produced a wider range of results. The discordance of these results suggests that POC glucometer glucose data should be interpreted in the context of methodology- and brand-specific reference intervals along with concurrent packed cell volume data.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Pojchanun Kanitthamniyom ◽  
Pei Yun Hon ◽  
Aiwu Zhou ◽  
Mohammad Yazid Abdad ◽  
Zhi Yun Leow ◽  
...  

AbstractCarbapenemase-producing Enterobacteriaceae (CPE) are a group of drug-resistant Gram-negative pathogens that are classified as a critical threat by the World Health Organization (WHO). Conventional methods of detecting antibiotic-resistant pathogens do not assess the resistance mechanism and are often time-consuming and laborious. We have developed a magnetic digital microfluidic (MDM) platform, known as MDM Carba, for the identification of CPE by measuring their ability to hydrolyze carbapenem antibiotics. MDM Carba offers the ability to rapidly test CPE and reduce the amount of reagents used compared with conventional phenotypic testing. On the MDM Carba platform, tests are performed in droplets that function as reaction chambers, and fluidic operations are accomplished by manipulating these droplets with magnetic force. The simple droplet-based magnetic fluidic operation allows easy system automation and simplified hands-on operation. Because of the unique “power-free” operation of MDM technology, the MDM Carba platform can also be operated manually, showing great potential for point-of-care testing in resource-limited settings. We tested 27 bacterial isolates on the MDM Carba platform, and the results showed sensitivity and specificity that were comparable to those of the widely used Carba NP test. MDM Carba may shorten the overall turnaround time for CPE identification, thereby enabling more timely clinical decisions for better clinical outcomes. MDM Carba is a technological platform that can be further developed to improve diagnostics for other types of antibiotic resistance with minor modifications.


Biosensors ◽  
2020 ◽  
Vol 11 (1) ◽  
pp. 4
Author(s):  
Donggee Rho ◽  
Seunghyun Kim

An optical cavity-based biosensor (OCB) has been developed for point-of-care (POC) applications. This label-free biosensor employs low-cost components and simple fabrication processes to lower the overall cost while achieving high sensitivity using a differential detection method. To experimentally demonstrate its limit of detection (LOD), we conducted biosensing experiments with streptavidin and C-reactive protein (CRP). The optical cavity structure was optimized further for better sensitivity and easier fluid control. We utilized the polymer swelling property to fine-tune the optical cavity width, which significantly improved the success rate to produce measurable samples. Four different concentrations of streptavidin were tested in triplicate, and the LOD of the OCB was determined to be 1.35 nM. The OCB also successfully detected three different concentrations of human CRP using biotinylated CRP antibody. The LOD for CRP detection was 377 pM. All measurements were done using a small sample volume of 15 µL within 30 min. By reducing the sensing area, improving the functionalization and passivation processes, and increasing the sample volume, the LOD of the OCB are estimated to be reduced further to the femto-molar range. Overall, the demonstrated capability of the OCB in the present work shows great potential to be used as a promising POC biosensor.