scholarly journals Effect of treatment technique on radiation exposure in mechanical thrombectomy for acute ischaemic stroke: A matched-pair analysis

2020 ◽  
Vol 33 (4) ◽  
pp. 286-291 ◽  
Author(s):  
Charlotte S Weyland ◽  
Ulf Neuberger ◽  
Fatih Seker ◽  
Simon Nagel ◽  
Peter Arthur Ringleb ◽  
...  

Objective This study aimed to compare radiation exposure (RE) in patients receiving mechanical thrombectomy (MT) for large-vessel occlusions in the anterior circulation using direct thrombo-aspiration (DT) versus stent-retriever thrombectomy under continuous distal aspiration (STA). Methods This was a retrospective single-centre analysis of an Institutional Review Board−approved stroke database of a comprehensive stroke centre focusing on RE per dose area product, procedure time (PT) and fluoroscopy time (FT) in patients receiving MT. Patients who received MT with DT were matched with patients treated using STA according to occlusion location, mode of anaesthesia, manoeuvre count and sex. Results Apart from patient age (DT: M = 74 years (standard deviation ( SD)=13 years); STA: M = 79 years ( SD = 11 years); p = 0.023), there was no difference in baseline patient characteristics ( n = 68 per group). PT (DT: median = 26 minutes (interquartile range (IQR) = 21–38 minutes); STA: median = 49 minutes (IQR 37–77 minutes); p < 0.0001) and FT (DT: median = 12 minutes (IQR 7–18 minutes); STA: median = 26 minutes (IQR 14–43 minutes); p < 0.0001) were shorter in patients who received MT using DT. RE (DT: median = 62.6 Gy·cm2 (IQR 41.7–89.4 Gy·cm2); STA: median = 89.8 Gy·cm2 (IQR 53.7–131.7 Gy·cm2); p = 0.034) was significantly lower in patients who received MT using DT. This represents a relative increase of RE, FT and PT by 43.6%, 116.6% and 88.5%, respectively, in patients who received MT using STA. Conclusion MT using DT is associated with shorter FT and PT and lower RE compared to matched patients treated with STA.

Author(s):  
C. Zaeske ◽  
L. Goertz ◽  
J. Kottlors ◽  
M. Schlamann ◽  
O. A. Onur ◽  
...  

Abstract Objectives The objective of this study was to compare clinical outcome and procedural differences of mechanical thrombectomy (MT) during on-call with regular operating hours. We particularly focused on dosimetric data which may serve as potential surrogates for patient outcome. Methods A total of 246 consecutive patients who underwent MT in acute anterior circulation stroke between November 2017 and March 2020 were retrospectively included. Patients treated (1) during standard operational hours (n = 102), (2) daytime on-call duty (n = 38) and (3) nighttime on-call duty (n = 106) were compared with respect to their pre-interventional status, procedural specifics, including dosimetrics (dose area product (DAP), fluoroscopy time and procedural time), and outcome. Results The collectives treated outside the regular operational hours showed an increased in-hospital mortality (standard operational hours 7% (7/102), daytime on-call duty 16% (6/38), nighttime on-call duty 20% (21/106), p = 0.02). Neither the dosimetric parameters nor baseline characteristics other procedural specifics and outcome parameters differed significantly between groups (p > 0.05 each). In most cases (> 90%), a successful reperfusion was achieved (TICI ≥ 2b). Conclusions We found an increased in-hospital mortality in patients admitted at night and during weekends which was not explained by technical aspects of MT. Key Points • There is an increased mortality of stroke patients admitted at night and on weekends. • This is not explained by technical aspects of mechanical thrombectomy. • There were no statistical differences in the comparison of parameters linked to the radiation exposure, such as DAP, fluoroscopy time and procedure time.


2019 ◽  
Vol 12 (5) ◽  
pp. 455-459 ◽  
Author(s):  
Felix Hemmerich ◽  
Charlotte S Weyland ◽  
Silvia Schönenberger ◽  
Peter A Ringleb ◽  
Markus A Möhlenbruch ◽  
...  

PurposeTo determine the effect of general anesthesia (GA) versus conscious sedation (CS) on radiation exposure (RE), procedure time (PT), and fluoroscopy time (FT) in patients receiving endovascular stroke treatment (EST) for large vessel occlusions (LVOs) in the anterior circulation.MethodsRetrospective analysis of an institutional review board−approved prospective stroke database of a comprehensive stroke center focusing on RE (as dose area product (DAP) in Gy.cm², median (IQR)), PT, and FT (in minutes, median (IQR)) in patients receiving EST for LVOs of the anterior circulation according to the mode of anesthesia during the intervention.ResultsOverall 544 patients were included in this analysis (GA: n=143, CS: n=401). For all included LVOs in the anterior circulation PTs (GA: 69 (44–100); CS: 59 (37–99); p=0.235), FTs (GA: 33 (20–56); CS: 29 (16–51); p=0.286), and RE (DAP, GA: 116.23 (73.47–173.41); CS: 110.5 (68.35–184.65); p=0.929) were comparable. In a subgroup analysis of occlusions of the middle cerebral artery (M1-segment; GA: n=80/544, 14.7%; CS: n=211/544, 38.8%), PTs (GA: 69 (37–101); CS: 54 (35 – 89); p=0.223), FTs (GA: 33 (19–55); CS: 25 (14–48); p=0.264), and RE (DAP, GA: 110.91 (66.8–169.12); CS: 103.8 (63.17–181); p=0.893) were similar.ConclusionIn this retrospective analysis, no effect of the mode of anesthesia on the radiation exposure during EST was detected as GA and CS showed comparable PT, FT, and DAPs.


2020 ◽  
Vol 62 (12) ◽  
pp. 1701-1707
Author(s):  
Charlotte S. Weyland ◽  
Arne Potreck ◽  
Ulf Neuberger ◽  
Markus A. Möhlenbruch ◽  
Simon Nagel ◽  
...  

Abstract Purpose To determine the radiation exposure in endovascular stroke treatment (EST) of acute basilar artery occlusions (BAO) and compare it with radiation exposure of EST for embolic middle cerebral artery occlusions (MCAO). Methods In this retrospective analysis of an institutional review board−approved prospective stroke database of a comprehensive stroke center, we focused on radiation exposure (as per dose area product in Gy × cm2, median (IQR)), procedure time, and fluoroscopy time (in minutes, median [IQR]) in patients receiving EST for BAO. Patients who received EST for BAO were matched case by case with patients who received EST for MCAO according to number of thrombectomy attempts, target vessel reperfusion result, and thrombectomy technique. Results Overall 180 patients (n = 90 in each group) were included in this analysis. General anesthesia was conducted more often during EST of BAO (BAO: 75 (83.3%); MCAO: 18 (31.1%), p < 0.001). Procedure time (BAO: 31 (20–43); MCAO: 27 (18–38); p value 0.226) and fluoroscopy time (BAO: 29 (20–59); MCAO: 29 (17–49), p value 0.317) were comparable. Radiation exposure was significantly higher in patients receiving EST for BAO (BAO: 123.4 (78.7–204.2); MCAO: 94.3 (65.5–163.7), p value 0.046), which represents an increase by 23.7%. Conclusion Endovascular stroke treatment of basilar artery occlusions is associated with a higher radiation exposure compared with treatment of middle cerebral artery occlusions.


2020 ◽  
Vol 33 (6) ◽  
pp. 838-844
Author(s):  
Jan-Helge Klingler ◽  
Ulrich Hubbe ◽  
Christoph Scholz ◽  
Florian Volz ◽  
Marc Hohenhaus ◽  
...  

OBJECTIVEIntraoperative 3D imaging and navigation is increasingly used for minimally invasive spine surgery. A novel, noninvasive patient tracker that is adhered as a mask on the skin for 3D navigation necessitates a larger intraoperative 3D image set for appropriate referencing. This enlarged 3D image data set can be acquired by a state-of-the-art 3D C-arm device that is equipped with a large flat-panel detector. However, the presumably associated higher radiation exposure to the patient has essentially not yet been investigated and is therefore the objective of this study.METHODSPatients were retrospectively included if a thoracolumbar 3D scan was performed intraoperatively between 2016 and 2019 using a 3D C-arm with a large 30 × 30–cm flat-panel detector (3D scan volume 4096 cm3) or a 3D C-arm with a smaller 20 × 20–cm flat-panel detector (3D scan volume 2097 cm3), and the dose area product was available for the 3D scan. Additionally, the fluoroscopy time and the number of fluoroscopic images per 3D scan, as well as the BMI of the patients, were recorded.RESULTSThe authors compared 62 intraoperative thoracolumbar 3D scans using the 3D C-arm with a large flat-panel detector and 12 3D scans using the 3D C-arm with a small flat-panel detector. Overall, the 3D C-arm with a large flat-panel detector required more fluoroscopic images per scan (mean 389.0 ± 8.4 vs 117.0 ± 4.6, p < 0.0001), leading to a significantly higher dose area product (mean 1028.6 ± 767.9 vs 457.1 ± 118.9 cGy × cm2, p = 0.0044).CONCLUSIONSThe novel, noninvasive patient tracker mask facilitates intraoperative 3D navigation while eliminating the need for an additional skin incision with detachment of the autochthonous muscles. However, the use of this patient tracker mask requires a larger intraoperative 3D image data set for accurate registration, resulting in a 2.25 times higher radiation exposure to the patient. The use of the patient tracker mask should thus be based on an individual decision, especially taking into considering the radiation exposure and extent of instrumentation.


QJM ◽  
2021 ◽  
Vol 114 (Supplement_1) ◽  
Author(s):  
Ahmed Abdelrazik ◽  
Youssef Amin ◽  
Alaa Roushdy ◽  
Maiy El Sayed

Abstract Aim and objectives The aim of the study is to assess the average radiation doses recorded per procedure in Ain Shams University Hospital pediatric cath lab to set benchmarks of radiation exposure in our institute. Patients and Methods The study included 198 patients who presented to Ain Shams cardiac pediatric cath lab who undergone interventional (BPV, BAV, ASD device closure, VSD device closure, PDA coil/device closure, Coarctation Stent/balloon) and diagnostic (Hemodynamics study, Diagnostic cath) heart catheterization. Radiation doses were measured without any interference with the operator’s preferences. Results Radiation dosages were measured in total AirKerma, Dose area product (DAP), and fluoroscopy time to set the benchmarks for radiation exposure in our institute per procedure. VSD device closure showed the highest radiation exposure followed by Coarctation stenting. Lowest radiation dosage was in PDA coil closure followed by ASD device closure then BPV. Conclusion Benchmarks for radiation exposure per procedure in pediatric cath lab in our institute were set and compared to each other.


2018 ◽  
Vol 179 (4) ◽  
pp. 261-267 ◽  
Author(s):  
C T Fuss ◽  
M Treitl ◽  
N Rayes ◽  
P Podrabsky ◽  
W K Fenske ◽  
...  

Objective Adrenal vein sampling (AVS) represents the current diagnostic standard for subtype differentiation in primary aldosteronism (PA). However, AVS has its drawbacks. It is invasive, expensive, requires an experienced interventional radiologist and comes with radiation exposure. However, exact radiation exposure of patients undergoing AVS has never been examined. Design and methods We retrospectively analyzed radiation exposure of 656 AVS performed between 1999 and 2017 at four university hospitals. The primary outcomes were dose area product (DAP) and fluoroscopy time (FT). Consecutively the effective dose (ED) was approximately calculated. Results Median DAP was found to be 32.5 Gy*cm2 (0.3–3181) and FT 18 min (0.3–184). The calculated ED was 6.4 mSv (0.1–636). Remarkably, values between participating centers highly varied: Median DAP ranged from 16 to 147 Gy*cm2, FT from 16 to 27 min, and ED from 3.2 to 29 mSv. As main reason for this variation, differences regarding AVS protocols between centers could be identified, such as number of sampling locations, frames per second and the use of digital subtraction angiographies. Conclusion This first systematic assessment of radiation exposure in AVS not only shows fairly high values for patients, but also states notable differences among the centers. Thus, we not only recommend taking into account the risk of radiation exposure, when referring patients to undergo AVS, but also to establish improved standard operating procedures to prevent unnecessary radiation exposure.


Stroke ◽  
2013 ◽  
Vol 44 (suppl_1) ◽  
Author(s):  
Dolora Wisco ◽  
KEN UCHINO ◽  
ESTEBAN CHENG CHING ◽  
Shazia Alam ◽  
SHUMEI MAN ◽  
...  

INTRODUCTION: In-hospital stroke (IHS) presents a different treatment challenge than out of hospital stroke. IHS often has contraindication to IV tPA, such as such as recent surgery, MI, and use of anticoagulation. Intra-arterial therapy (IAT) with tPA and/or mechanical thrombectomy is an option for large vessel acute IHS with contraindications to or fail to recanalize with IV tPA, to restore cerebral perfusion. Objective: To assess the characteristics and outcomes of patients with in-hospital strokes large vessel occlusion who receive IAT. Methods: From our database of patients from 1/1/2008 to 12/31/2011 who had IAT for an acute stroke due to large vessel occlusion, in hospital strokes and out of hospital strokes were identified. Patient characteristics, imaging, and outcomes were retrospectively collected. Statistical analysis was performed on JMP 9.0. Result: 151 patients were included, 23 (15%) were in-hospital strokes (IHS) and 128 (85%) were out of hospital strokes (OHS). Initial median NIHSS of 17 and 16 respectively (p=0.3). IHS were frequently in the cardiology/CTS service (14, 60%) for CHF and cardiac valve repair (12, 52%). Other comorbidities present were atrial fibrillation (68%), hypertension (68%), and hyperlipidemia (56%). Seven (30%) were on warfarin prior to admission, but all had subtherapeutic INR. Three (13%) IHS received IV tPA. The time from last known well (LKW) to non-contrast CT brain was 80 min, and to CTA was 113 min in IHS, and 147 min and 229 min respectively in OHS (p = 0.0003). 20 (87%) had lesion in the anterior circulation. LKW to IAT recanalization was 248 min in IHS, compared to 375 min in OHS. Recanalization rate was 68% for IHS and 81% for OHS (p=0.2). Nine (39%) IHS had favorable mRS of 1 to 3 at 90 days, compared to 44 (34%) OHS, (p = 0.6). Despite faster recanalization time, there was no difference in the 90 day mortality of IHS v OHS (48% vs 30%, p = 0.1), and IHS had greater 1 year mortality (65% vs 30%, p = 0.005). Discussion: In-hospital strokes have higher mortality than out of hospital strokes. There is a role for IAT In carefully selected IHS with large vessel occlusion. A multicenter study is needed to reveal the characteristics of IHS patients who may benefit from IAT.


2021 ◽  
Vol 94 (1117) ◽  
pp. 20190878
Author(s):  
Anna Kropelnicki ◽  
Rosemary Eaton ◽  
Alexandra Adamczyk ◽  
Jacqueline Waterman ◽  
Pegah Mohaghegh

Objective: Mini C-arm fluoroscopes are widely used by orthopaedic surgeons for intraoperative image guidance without the need for radiographers. This puts the responsibility for radiation exposure firmly with the operating surgeon. In order to maintain safe and best practice under U.K. Ionising Radiation (Medical Exposure) Regulations, one must limit radiation exposure and audit performance using national diagnostic reference levels (DRLs). In the case of the mini C-arm, there are no national DRLs. IR(ME)R, therefore, require the establishment of local DRLs by each hospital to act as an alternative guideline for safe radiation use. The aim of our audit was to establish local DRLs based on our experience operating with the use of the mini C-arm over the last 7 years. Methods: This retrospective audit evaluates the end dose–area product (DAP) recorded for common trauma and orthopaedic procedures using the mini C-arm in a busy district general hospital. We present the quartile data and have set the cut-off point as the third quartile for formulating the local DRLs, consistent with the methodology for the conventional fluoroscope. Results: For our data set (n = 1664), the third quartile DAP values were lowest for surgeries to the forearm (5.38 cGycm2), hand (7.62 cGycm2), and foot/ankle (8.56 cGycm2), and highest for wrist (10.64 cGycm2) and elbow (14.61 cGycm2) procedures. Advances in knowledge: To our knowledge, this is the largest data set used to establish local DRLs. Other centres may find our guidelines useful whilst they establish their own local DRLs.


2016 ◽  
Vol 98 (7) ◽  
pp. 483-487 ◽  
Author(s):  
JF Maempel ◽  
OD Stone ◽  
AW Murray

Introduction Surgical procedures to manage trauma to the wrist, forearm and elbow in children are very common. Image intensifiers are used routinely, yet studies/guidelines that quantify expected radiation exposure in such procedures are lacking. Methods Information on demographics, injury type, surgeon grade and dose area product (DAP) of radiation exposure per procedure was collected prospectively for 248 patients undergoing manipulation/fixation of injuries to the elbow, forearm or wrist at a paediatric hospital over 1 year. Results DAP exposure (in cGycm2) differed significantly across different procedures (p<0.001): wrist manipulation under anaesthesia (MUA; median, 0.39), wrist k-wiring (1.01), forearm MUA (0.50), flexible nailing of the forearm (2.67), supracondylar fracture MUA and k-wiring (2.23) and open reduction and internal fixation of the lateral humeral condyle (0.96). Fixation of a Gartland grade-3 supracondylar fracture (2.94cGycm2) was associated with higher exposure than grade-2 fixation (1.95cGycm2) (p=0.048). Fractures of the wrist or forearm necessitating metalwork fixation resulted in higher exposure than those requiring manipulation only (both p<0.001). For procedures undertaken by trainees, trainee seniority (between year-5 and year-8 and clinical fellow, p≥0.24) did not affect the DAP significantly. Conclusions The spectrum of radiation exposures for common procedures utilised in the management of paediatric upper limb trauma were quantified. These findings will be useful to surgeons auditing their practice and quantifying radiation-associated risks to patients. Our data may serve as a basis for implementing protocols designed to improve patient safety.


Sign in / Sign up

Export Citation Format

Share Document