scholarly journals Sensitivity and Specificity of Gene Xpert in the Diagnosis of Spinal Tuberculosis: A Prospective Controlled Clinical Study

2019 ◽  
Vol 10 (5) ◽  
pp. 553-558
Author(s):  
Anil M. Solanki ◽  
Saumyajit Basu ◽  
Amitava Biswas ◽  
Subhendu Roy ◽  
Aditya Banta

Study Design: Prospective matched cohort study Objective: To evaluate the sensitivity and specificity of Gene Xpert in the diagnosis of spinal tuberculosis. Methods: From January 2016 to August 2018, Gene Xpert results were prospectively studied in 68 patients of clinicoradiologically suspected spinal tuberculosis (STB) and a control group (CG) of 92 patients, all of whom underwent computed tomography–guided/C-arm-guided/open surgical biopsy. Sensitivity, specificity, positive predictive value, and negative predictive value are obtained using standard equations. Results: Out of 68 cases of STB, Gene Xpert was positive in 62 (true positive: 62/68) and negative in 6 (false negative: 6/68). Gene Xpert was negative for all 92 cases of CG (true negative: 92/92, false positive 0/92). Thus, in our series, sensitivity of Gene Xpert is 91.18%, specificity is 100%, positive predictive value is 100%, and negative predictive value is 93.88%. Out of all cases of STB, 62/68 (91.18%) were Gene Xpert positive, but only 35/64 (54.69%) was acid-fast bacilli (AFB) culture positive and 53/60(88.33%) was histopathologically conclusive of TB. Also, Gene Xpert was positive in 7/7 (100%) cases of STB in which histopathology were inconclusive and 25/29 (86.21%) cases of STB in which AFB culture was negative. Conclusion: In STB, Gene Xpert clearly outperforms AFB culture and histopathology due to its high sensitivity and specificity apart from being rapid in diagnosis. Hence it is justified to diagnose spinal tuberculosis by Gene Xpert though histopathology is confirmative and AFB culture remains the gold standard.

10.17158/522 ◽  
2016 ◽  
Vol 19 (2) ◽  
Author(s):  
John Mark De Real

<p>The main objective of this study was to test the sensitivity and specificity of rapid diagnostic test for malaria parasite in comparison to slide microscopy as gold standard. Data were acquired from blood mass survey of malaria infection conducted in the community of Paquibato district, Davao City. There were 377 total participants examined through Rapid Diagnostic Test (RDT) and slide microscopy. Of the 377 participants tested, 16 (4.24%) of them were positive to Plasmodium falciparum and 68 (18.04%) were positive to Plasmodium vivax using slide microscopy. Of the 16 participants’ positive for P. faciparum, PfRDT (HRP-2) correctly identified 13 expressing 81.25% (low) sensitivity of the tool. Of the 68 participants’ positive for P. vivax, PvRDT (pLDH) correctly identified 65 expressing 95.59% (high) sensitivity. Both of the RDTs (HRP-2 and pLDH), however, attained 100% specificity. PfRDT (HRP-2) has a positive predictive value of 100% and a negative predictive value of 99.2%, likewise PvRDT (pLDH) has a positive predictive value of 100% and a negative predictive value of 99.04%, all in all, suggesting a high degree of reliability of SD BIOLINE Malaria Antigen P.f/P.v. the data showed no significant difference on the performance level of RDT, albeit less sensitive, compared to slide microscopy.</p><p><strong>Keywords:</strong> Health, malaria, sensitivity, specificity, HRP-2, pLDH, descriptive Davao City, Philippines.</p><div> </div>


2020 ◽  
Vol 02 (02) ◽  
pp. 70-74
Author(s):  
T. S. Chowdhury ◽  
M. M. Shume ◽  
T. A. Chowdhury

Background: Tubal evaluation is an integral part of the evaluation of female infertility. Hysterosalpingography (HSG) is the radiographic evaluation of the uterus and fallopian tubes, which has been used as a first-line test for tubal assessment since 1920s. Laparoscopy is considered to be the gold standard for the diagnosis and management of tubo-peritoneal pathology. The objective of this study is to evaluate and compare the diagnostic value of both HSG and laparoscopy for assessment of tubal occlusion. Methods: This is a prospective cross-sectional study. Laparoscopic chromopertubation was conducted on 125 consecutive infertile women who attended the “Infertility Management Center” from October 2018 to September 2019. All patients had HSG performed in the radiology department of different hospitals. Laparoscopic findings were used as a reference standard to analyze the findings of HSG for tubal occlusion. Data were analyzed by SPSS software (version 16). Results: Normal HSG findings were seen in 53 patients (42.4%). Unilateral tubal occlusion was present in 38 (30.7%), and bilateral occlusion in 34 (27.2%) patients. Laparoscopy showed normal findings in 85 (68.0%) patients. Unilateral tubal occlusion was demonstrated in laparoscopy in 27 (21.6%) and bilateral tubal occlusion in 13 (10.4%) patients. HSG findings for diagnosis of tubal occlusion was true positive in 30 (24%) cases, false positive in 42 (33.6%) cases, false negative in 10 (8%) cases, and true negative in 43 (34.4%) cases in comparison to laparoscopy findings. Sensitivity of HSG was found to be 75.0%, specificity 50.6%, and accuracy 58.4%. Positive predictive value and negative predictive value were 41.7% and 81.1%, respectively. Conclusion: HSG is widely used for tubal assessment in Bangladesh as it is a relatively inexpensive, low-risk office procedure. But it has a low specificity and positive predictive value with a relatively high negative predictive value. Laparoscopy, on the other hand, is preferable when there is high suspicion of tubal pathology.


2013 ◽  
Vol 57 (9) ◽  
pp. 4578-4580 ◽  
Author(s):  
Nathalie Tijet ◽  
David Boyd ◽  
Samir N. Patel ◽  
Michael R. Mulvey ◽  
Roberto G. Melano

ABSTRACTThe Carba NP test was evaluated against a panel of 244 carbapenemase- and non-carbapenemase-producingEnterobacteriaceaeandPseudomonas aeruginosaisolates. We confirmed the 100% specificity and positive predictive value of the test, but the sensitivity and negative predictive value were 72.5% and 69.2%, respectively, and increased to 80% and 77.3%, respectively, using a more concentrated bacterial extract. False-negative results were associated with mucoid strains or linked to enzymes with low carbapenemase activity, particularly OXA-48-like, which has emerged globally in enterobacteria.


2021 ◽  
Vol 24 (2) ◽  
pp. 196-203
Author(s):  
Elahe Fini ◽  
◽  
Neda Nasirian ◽  
Bahram Hosein Beigy ◽  
◽  
...  

Background and Aim: Ovarian cancer is among the most common cancers in women worldwide. CA125 is the most frequent biomarker used in the screening for ovarian cancer. CA125 has no high sensitivity and specificity as a screening test in the medical community; however, because of being simple and noninvasive, it is almost always requested for evaluation and ruling out cancer. It plays an important role in the treatment and post-treatment process, the prediction of prognosis, and the relapse of the disease. The present study aimed to determine the relationship between a high level of CA125 tumor marker and ovarian cancer by detecting spesivity, sensivity, positive and negative predictive values. Methods & Materials: In this cross-sectional study, all cases undergoing CA125 test in Velayat Hospital in 2017-1028 were evaluated for having ovarian cancer. In addition, the CA125 level was compared between healthy individuals and patients with ovarian cancer. Finally, the obtained data were analyzed using SPSS. Ethical Considerations: The present study was approved by the Qazvin University of Medical Sciences (Ethics Code: IR.QUMS.REC.1396.316). Results: In this study, 35.3% of the study participants received a definite diagnosis of ovarian cancer. Generally, CA125 values were negative in 41.8% and positive in.58.2% of the study subjects. The sensitivity of the test was measured as 80.1%, the specivity as 53.6%, the positive predictive value equaled 48.4%, and the negative predictive value was measured as 83%. There was a significant relationship between age and the presence of ovarian cancer, and serum CA125 levels. Conclusion: The present study suggested that age and the serum level of CA125 were statistically significant. Finally, CA125 levels were significantly related to ovarian cancer. It provided moderate specivity and specivity as well as low positive predictive value and high negative predictive value as a tumor marker; it is valuable for ruling out of tumor but not appropriate as a screening test.


2001 ◽  
Vol 7 (6) ◽  
pp. 359-363 ◽  
Author(s):  
M Tintoré ◽  
A Rovira ◽  
L Brieva ◽  
E Grivé ◽  
R Jardí ◽  
...  

Aim of the study: To evaluate and compare the capacity of oligoclonal bands (OB) and three sets of MR imaging criteria to predict the conversion of clinically isolated syndromes (CIS) to clinically definite multiple sclerosis (CDMS). Patients and methods: One hundred and twelve patients with CIS were prospectively studied with MR imaging and determination of OB. Based on the clinical follow-up (conversion or not conversion to CDMS), we calculated the sensitivity, specificity accuracy, positive and negative predictive value of the OB, and MR imaging criteria proposed by Paty et al, Fazekas et al and Barkhof et al. Results: CDMS developed in 26 (23.2%) patients after a mean follow-up of 31 months (range 12-62). OB were positive in 70 (62.5%) patients and were associated with a higher risk of developing CDMS. OB showed a sensitivity of 81%, specificity of 43%, accuracy of 52%, positive predictive value (PPV) of 30% and negative predictive value (NPV) of 88%. Paty and Fazekas criteria showed the same results with a sensitivity of 77%, specificity of 51%, accuracy of 57%, positive predictive value of 32% and negative predictive value of 88%. Barkhof criteria showed a sensitivity of 65%, specificity of 70%, accuracy of 69%, PPV of 40% and NPV of 87%. The greatest accuracy was achieved when patients with positive OB and three or four Barkhof's criteria were selected. Conclusions: We observed a high prevalence of OB in CIS. OB and MR imaging (Paty's and Fazekas' criteria) have high sensitivity. Barkhof's criteria have a higher specificity. Both OB and MR imaging criteria have a high negative predictive value.


2015 ◽  
Vol 51 (5) ◽  
pp. 306-310 ◽  
Author(s):  
Lauren Cunningham ◽  
Audrey Cook ◽  
Andrew Hanzlicek ◽  
Kenneth Harkin ◽  
Joseph Wheat ◽  
...  

The objective of this study was to evaluate the sensitivity and specificity of an antigen enzyme immunoassay (EIA) on urine samples for the diagnosis of histoplasmosis in dogs. This retrospective medical records review included canine cases with urine samples submitted for Histoplasma EIA antigen assay between 2007 and 2011 from three veterinary institutions. Cases for which urine samples were submitted for Histoplasma antigen testing were reviewed and compared to the gold standard of finding Histoplasma organisms or an alternative diagnosis on cytology or histopathology. Sensitivity, specificity, negative predictive value, positive predictive value, and the kappa coefficient and associated confidence interval were calculated for the EIA-based Histoplasma antigen assay. Sixty cases met the inclusion criteria. Seventeen cases were considered true positives based on identification of the organism, and 41 cases were considered true negatives with an alternative definitive diagnosis. Two cases were considered false negatives, and there were no false positives. Sensitivity was 89.47% and the negative predictive value was 95.35%. Specificity and the positive predictive value were both 100%. The kappa coefficient was 0.9207 (95% confidence interval, 0.8131–1). The Histoplasma antigen EIA test demonstrated high specificity and sensitivity for the diagnosis of histoplasmosis in dogs.


Blood ◽  
2019 ◽  
Vol 134 (Supplement_1) ◽  
pp. 4689-4689
Author(s):  
Sriman Swarup ◽  
Somedeb Ball ◽  
Nimesh Adhikari ◽  
Anita Sultan ◽  
Khatrina Swarup ◽  
...  

Introduction: Heparin induced thrombocytopenia (HIT) is a severe prothrombotic condition, usually triggered by exposure to heparin products. It is characterized by platelet activation induced by the formation of antibodies to the platelet factor 4 (PF4)/ heparin polyanion complexes. Diagnostic algorithm includes clinical scoring (4T score) alongside serological test for detection of these antibodies (HIT-Ab), while serotonin release assay (SRA) remains the gold- standard for confirmation. The automated latex immunoturbidometric assay (LIA) has recently been FDA approved as a screening tool for HIT and is a potential alternative to the conventional particle immunofiltration assay (PIFA) for time-sensitive detection of HIT-Ab to guide treatment considerations. We recently introduced LIA in our institution. In this study, we present our experience with LIA in comparison to PIFA in the diagnosis of HIT. Methods: We retrospectively reviewed the charts of all the patients on whom a PIFA was ordered between March 2017 and March 2018 in our hospital. We collected information on the results of the PIFA and SRA (if available). We replaced PIFA with LIA for HIT screening. Then, we introduced a structured protocol for diagnosis of HIT in our institution by incorporating 4T scoring alongside LIA order in the electronic medical record (EMR), in December 2018. We reviewed the EMR of all the patients on whom HIT-Ab test (LIA) was ordered between January and June of 2019, and collected similar information as before. All the data were compiled in a single master excel sheet for calculation of performance characteristics (sensitivity, specificity, positive and negative predictive values) for both PIFA and LIA. A patient was considered to have the diagnosis of HIT if the result of SRA was available and positive. Results: In the first phase, a total of 31 orders for SRA was noted against 170 PIFA orders. Five patients had a positive SRA, of whom two were PIFA negative. Half the patients with a negative SRA result were positive for PIFA. Hence, the sensitivity and specificity of PIFA test for our study population were noted to be 60% and 50%, respectively. PIFA had a positive predictive value (PPV) of mere 18.75% for the diagnosis of HIT, whereas the negative predictive value (NPV) was found to be 86.66%. Introduction of structured protocol for HIT diagnosis substantially reduced the number of inappropriate SRA orders in the second phase. On review of data for six months with the new HIT-Ab test LIA, SRA was ordered in only eight patients, to go with 69 orders for the LIA. The result of LIA was positive in all three patients with a positive SRA, whereas it was false positive in four instances. Only one patient was negative for both LIA and SRA during this period. LIA was found to be 100% sensitive and 20% specific for the diagnosis of HIT in our sample. PPV and NPV for LIA were 42.85% and 100%, respectively. Conclusion: The sensitivity and specificity of LIA were found to be 100% and 20%, respectively, in our study population, which is different from the earlier report (Warkentin et al. 2017). The small sample size is a limitation of our study. Higher PPV and NPV for LIA, with its quick turnaround time, make it a useful alternative for the time-sensitive determination of post-test probability for HIT in patients. [HIT- Ab- Heparin Induced Thrombocytopenia Antibody, PIFA- Particle Immunofiltration Assay, LIA- Latex Immunoturbidometric Assay, SRA- Serotonin Release Assay, +ve- Positive, -ve - Negative, PPV- Positive Predictive Value, NPV- Negative Predictive Value] Disclosures No relevant conflicts of interest to declare.


Author(s):  
Dr. Chaturbhuj Prasad Swarnkar ◽  
Dr. Shiv Raj Meena

Background- Rotator cuff tears are one of the most common causes of shoulder pain for which patients seek treatment. As in our daily work, the shoulder joint is the most frequently used, there is higher chance of having shoulder joint injury. The aim of the study is to compare the efficacy of MRI in diagnosing shoulder pathologies in comparison to arthroscopy, considering arthroscopy as the gold standard. Methods- 30 Patient with suspected rotator cuff injury patients, between 18-80 years of age was included in the study. MRI of the shoulder joint was done followed by shoulder arthroscopy. The data collected was analysed for the significant correlation between MRI of shoulder and arthroscopic findings by kappa statistics. Results- The accuracy of MRI in diagnosis of rotator cuff partial tears, was 90%, while sensitivity and specificity was 100.00%, 78.57% and positive predictive value was 84.21% and negative predictive value was 100.00% and accuracy of MRI in diagnosis of rotator cuff full tears, was 86.67%, while sensitivity and specificity was 63.64%, 100.00%) and positive predictive value was 100.00% and negative predictive value was 82.61% in our study. Conclusion- Our study demonstrates a high sensitivity and specificity for the MRI diagnosis of both partial and full thickness rotator cuff tears and good correlation with arthroscopic findings. Keywords: Rotator cuff, Shoulder pain, Arthroscopy, MRI.


2019 ◽  
Vol 2019 ◽  
pp. 1-5
Author(s):  
Silvio A. Ñamendys-Silva ◽  
Emerson Joachin-Sánchez ◽  
Aranza Joffre-Torres ◽  
Bertha M. Córdova-Sánchez ◽  
Guadalupe Ferrer-Burgos ◽  
...  

Background. The quick sequential organ failure assessment (qSOFA) and the Eastern Cooperative Oncologic Group (ECOG) scale are simple and easy parameters to measure because they do not require laboratory tests. The objective of this study was to compare the discriminatory capacity of the qSOFA and ECOG to predict hospital mortality in postsurgical cancer patients without infection. Methods. During the period 2013–2017, we prospectively collected data of all patients without infection who were admitted to the ICU during the postoperative period, except those who stayed in the ICU for <24 hours or patients under 18 years. The ECOG score during the last month before hospitalization and the qSOFA performed during the first hour after admission to the intensive care unit (ICU) were collected. The primary outcome for this study was the in-hospital mortality rate. Results. A total of 315 patients were included. The ICU and hospital mortality rates were 6% and 9.2%, respectively. No difference was observed between the qSOFA [AUC=0.75 (95% CI = 0.69-0.79)] and the ECOG scores [AUC=0.68 (95%CI =0.62-0.73)] (p=0.221) for predicting in-hospital mortality. qSOFA greater than 1 predicted in-hospital mortality with a high sensitivity (100%) but low specificity (38.8%); positive predictive value of 26.3% and negative predictive value of 93.1% compared to 74.4% of specificity, 55.1% of sensitivity%; positive predictive value of 18% and negative predictive value of 94.2% for an ECOG score greater than 1. Multivariable Cox regression analysis identified two independent predicting factors of in-hospital mortality, which included ECOG score during the last month before hospitalization (HR: 1.46; 95 % CI: 1.06-2.00); qSOFA calculated in the first hours after ICU admission (OR: 3.17; 95 % CI: 1.79–5.63). Conclusion. No difference was observed between the qSOFA and ECOG for predicting in-hospital mortality. The qSOFA score performed during the first hour after admission to the ICU and ECOG scale during the last month before hospitalization were associated with in-hospital mortality in postsurgical cancer patients without infection. The qSOFA and ECOG score have a potential to be included as early warning tools for hospitalized postsurgical cancer patients without infection.


Sign in / Sign up

Export Citation Format

Share Document