Optical Density of 1.0 Is a Better Cutoff for Positive HIT Ab ELISA.

Blood ◽  
2009 ◽  
Vol 114 (22) ◽  
pp. 3515-3515
Author(s):  
Mohammad Ziari ◽  
Catherine Burke ◽  
Karen Matevosyan ◽  
Eugene P. Frenkel ◽  
Ravindra Sarode ◽  
...  

Abstract Abstract 3515 Poster Board III-452 Background Heparin-induced thrombocytopenia (HIT) is a clinicopathologic diagnosis based on pretest clinical assessment aided by the 4T score and confirmed by laboratory testing for the presence of anti-heparin-platelet factor 4 antibody (HIT Ab). Prompt and accurate diagnosis of HIT is paramount due to an extraordinary high risk of thrombosis and the inherent risk of bleeding and cost with the use direct thrombin inhibitors (DTI). The polyspecific enzyme linked immunosorbent assay (poly-ELISA) for the HIT Ab is the most commonly available test that detects IgG, IgM and IgA HIT Ab. The IgG-specific ELISA detects only IgG HIT Ab, the antibody that is known to cause HIT. The use of a second step ELISA with high-dose heparin in the reagent improves the specificity by demonstrating heparin-dependence of the antibody detected. Serotonin release assay (SRA) is considered the gold standard for detecting HIT Ab, but it is available only at a few select centers in the world. Past studies have shown that the probability of SRA positivity increases with the optical density (OD) unit of the ELISA. In particular, only 1-5% of patients with OD of 0.4 to 1.0 have a positive SRA, and increases to 89-100% when OD is greater than 2.0 (Warkentin et al, JTH 2008). The 4T score was developed to predict the probability of HIT. This score takes into account the severity of thrombocytopenia, timing of platelet fall with relation to heparin use, presence of new thrombosis, and other causes of thrombocytopenia. The high negative predictive value of the 4T score has been validated in multiple studies. However, the polyspecific ELISA was used in most of these studies, increasing the possibility of false positive tests. Study: We have collected a database of patients being tested for HIT at our institution, where the IgG-specific ELISA along with high-dose heparin inhibition is being used to detect the HIT Ab. We performed a retrospective review of the last 165 ELISAs performed and the clinical circumstances of the testing. Clinical data was reviewed in detail and patients were categorized as having definite HIT, probable HIT and not HIT. We hypothesize that the high negative predictive value of the 4T score combined with the more specific IgG-specific ELISA could allow the use of OD unit of 1.0 as a cutoff for positive ELISA rather than the current standard of 0.4. Results We identified 15 patients with OD>0.4; of these 10 had OD>1.0. 6 of the 10 had 4T score of 5 or higher, with 5 of the 6 considered to have definite HIT and 1 with probable HIT. 2 of the 4 patients with OD>1.0 and 4T score of 4 were not considered to have HIT, while 2 had probable HIT. 5 patients had OD of 0.4 to 1.0; 4 with 4T score of 4 were considered to have no HIT, while the last patient only had probable HIT with a 4T score of 6. Conclusion Based on these results, we conclude that the IgG-specific ELISA could use a cutoff of OD 1.0 for positive HIT Ab test. When the OD is between 0.4 and 1.0, the diagnosis of HIT should be entertained when a high risk 4T score is present. Thus the degree of “positivity” of the ELISA in conjunction with the 4T score can be used to properly identify and manage patients with probable or definite HIT. Our data confirms that testing “positive” for HIT Ab with the ELISA does not necessitate a diagnosis of HIT, but simply increases the probability of having HIT. Inherent risk of bleeding with the use of DTI and the lack of a reversal agent would dictate that the diagnosis of HIT is applied with a high degree of certainty. We believe that using a higher cutoff of 1.0 would improve our confidence in the diagnosis of HIT when used in conjunction with the 4T score. Further expansion of our study with more patient numbers would be necessary to confirm our preliminary findings. Disclosures: No relevant conflicts of interest to declare.

Blood ◽  
2009 ◽  
Vol 114 (22) ◽  
pp. 1328-1328
Author(s):  
Prapti A. Patel ◽  
Catherine Burke ◽  
Karen Matevosyan ◽  
Eugene P. Frenkel ◽  
Ravindra Sarode ◽  
...  

Abstract Abstract 1328 Poster Board I-350 Background Heparin-induced thrombocytopenia (HIT) is a clinicopathologic diagnosis based on pretest clinical assessment aided by the 4T score and confirmed by laboratory testing for the presence of anti-heparin-platelet factor 4 antibody (HIT Ab). Prompt and accurate diagnosis of HIT is paramount due to an extraordinarily high risk of thrombosis, and the inherent risk of bleeding and high cost of direct thrombin inhibitors (DTI). The polyspecific enzyme linked immunosorbent assay (poly-ELISA) for the HIT Ab is the most commonly available test that detects IgG, IgM and IgA HIT Ab. The IgG-specific ELISA detects only IgG HIT Ab, the antibody that is known to cause HIT. The use of a second step ELISA with high-dose heparin in the reagent improves the specificity by demonstrating heparin-dependence of the antibody detected. The 4T score was developed to predict the probability of HIT. This score takes into account the severity of thrombocytopenia, timing of platelet fall with relation to heparin use, presence of new thrombosis, and other causes of thrombocytopenia. The high negative predictive value of the 4T score has been validated in multiple studies (Bryant et al, BJH 2008). However, the polyspecific ELISA was used in most of these studies, increasing the possibility of false positive tests. Study We have collected a database of patients being tested for HIT at our institution, where the IgG-specific ELISA along with high-dose heparin inhibition is being used to detect the HIT Ab. We performed a retrospective review of the last 165 ELISAs performed and the clinical circumstances of the testing. We hypothesize that the high negative predictive value of the 4T score combined with the more specific IgG-specific ELISA could be used to rule out HIT and avoid the cost of testing and empiric use of DTI. Results 4T scores of 165 patients were analyzed and compared to the results of the HIT Ab. The distribution of optical density units of the ELISA according to 4T score is shown in Figure 1. Of the 165 patients, 107 patients (64%) had a 4T score of 0-3. Of those 107 patients, 2 patients had OD>0.4; both had no significant inhibition with the addition of high-dose heparin (Table 1). Thus none of the 107 patients had a positive IgG-specific ELISA for HIT Ab. Thus having a low 4T score has a sensitivity of 100% for IgG-specific ELISA for HIT Ab, specificity of 71%. This translates to a positive predictive value of 26%, and a negative predictive value of 100% (Table 2). Conclusion Based on our data, we conclude that patients with low 4T scores (0-3) are highly unlikely to have HIT. Therefore, we propose that patients with a low 4T score do not need the laboratory workup or empiric treatment for HIT. Since the majority of patients suspected to have HIT have low 4T scores, reserving testing and empiric therapy for patients with intermediate and high 4T scores can lead to significant cost savings, and avoidance of potentially devastating bleeding complications with DTI therapy. Disclosures No relevant conflicts of interest to declare.


Blood ◽  
2006 ◽  
Vol 108 (11) ◽  
pp. 1475-1475
Author(s):  
Kim A. Janatpour ◽  
Robert C. Gosselin ◽  
William E. Dager ◽  
Andrew Lee ◽  
John T. Owings ◽  
...  

Abstract Background: Heparin induced thrombocytopenia (HIT) is a potentially life threatening complication of heparin administration caused by antibodies directed to the heparin-platelet factor 4 (PF4) complex and characterized by thrombocytopenia with a seemingly paradoxical high risk of thrombosis. Diagnosis is challenging, and is based on both clinical suspicion and laboratory detection of heparin-PF4 antibodies. The Warkentin 4 T’s “pre-test” probability and Chong’s “post-test” probability models have been developed to aid the diagnosis of HIT. Enzyme-linked immunoabosorbant assay (ELISA) laboratory measurement of heparin-PF4 antibodies is commonly used but has a low positive predictive value for thrombosis. Recent reports suggest that using an ELISA optical density (OD) value of ≥ 1 may improve the predictive value for thrombosis. Methods: We performed a retrospective analysis of 105 patients with suspected HIT who were treated with a direct thrombin inhibitor and evaluated the anti-heparin-PF4 ELISA OD values and Warkentin 4 T’s scores for sensitivity, specificity, and positive and negative predictive values (PPV and NPV, respectively) using the Chong’s score to define HITBoth the manufacturer’s OD threshold of 0.4 and ≥ 1 were evaluated. Table 1. Comparison of sensitivity, specificity, and predictive values for 4 T’s and OD levels, alone and in combination Sensitivity (%) Specificity (%) NPV (%) PPV (%) For calculations, Chong’s categories of definite/probable and unlikely were used to define presence or absence of HIT. 4T’s score (high and low) 81 100 80 100 OD level 0.4 69 75 65 78 OD level ≥1 38 85 52 77 4T’s + OD 0.4 94 100 94 100 4T’s +OD ≥1 69 85 81 75 Results: The sensitivity, specificity and predictive value of ELISA alone were inferior to the 4 T’s clinical scorings system. The sensitivity and negative predictive values of the 4T’s score were improved by considering positive or negative ELISA test results. Conclusions: Consistent with previous reports, the PPV of a high probability 4T score alone was 100%. Thus, ELISA results might not change clinical decisions in this situation. Alternative anticoagulation might be inappropriately withheld in 20% of patients if a low probability 4T score alone were to be used for decision-making. The addition of ELISA data using an OD level of 0.4 increased the NPV to a threshold that might be considered clinically acceptable (94%) to withhold therapy. Addition of an OD level of ≥ 1 did not improve the PV of the 4 T’s. However, in contrast to other studies that found better predictive value to using this higher OD threshold, our study group was limited to people considered high risk for HIT. Validation of this strategy in a prospective trial with clinical endpoints should be considered.


2008 ◽  
Vol 47 (06) ◽  
pp. 235-238 ◽  
Author(s):  
M. Dietlein ◽  
C. Mauz-Körholz ◽  
A. Engert ◽  
P. Borchmann ◽  
O. Sabri ◽  
...  

SummaryThe high negative predictive value of FDG-PET in therapy control of Hodgkin lymphoma is proven by the data acquired up to now. Thus, the analysis of the HD15 trial has shown that consolidation radiotherapy might be omitted in PET negative patients after effective chemotherapy. Further response adapted therapy guided by PET seems to be a promising approach in reducing the toxicity for patients undergoing chemotherapy. The criteria used for the PET interpretation have been standardized by the German study groups for Hodgkin lymphoma patients and will be reevaluated in the current studies.


2018 ◽  
Vol 27 (6) ◽  
pp. 633-644 ◽  
Author(s):  
Marco Proietti ◽  
Alessio Farcomeni ◽  
Giulio Francesco Romiti ◽  
Arianna Di Rocco ◽  
Filippo Placentino ◽  
...  

Aims Many clinical scores for risk stratification in patients with atrial fibrillation have been proposed, and some have been useful in predicting all-cause mortality. We aim to analyse the relationship between clinical risk score and all-cause death occurrence in atrial fibrillation patients. Methods We performed a systematic search in PubMed and Scopus from inception to 22 July 2017. We considered the following scores: ATRIA-Stroke, ATRIA-Bleeding, CHADS2, CHA2DS2-VASc, HAS-BLED, HATCH and ORBIT. Papers reporting data about scores and all-cause death rates were considered. Results Fifty studies and 71 scores groups were included in the analysis, with 669,217 patients. Data on ATRIA-Bleeding, CHADS2, CHA2DS2-VASc and HAS-BLED were available. All the scores were significantly associated with an increased risk for all-cause death. All the scores showed modest predictive ability at five years (c-indexes (95% confidence interval) CHADS2: 0.64 (0.63–0.65), CHA2DS2-VASc: 0.62 (0.61–0.64), HAS-BLED: 0.62 (0.58–0.66)). Network meta-regression found no significant differences in predictive ability. CHA2DS2-VASc score had consistently high negative predictive value (≥94%) at one, three and five years of follow-up; conversely it showed the highest probability of being the best performing score (63% at one year, 60% at three years, 68% at five years). Conclusion In atrial fibrillation patients, contemporary clinical risk scores are associated with an increased risk of all-cause death. Use of these scores for death prediction in atrial fibrillation patients could be considered as part of holistic clinical assessment. The CHA2DS2-VASc score had consistently high negative predictive value during follow-up and the highest probability of being the best performing clinical score.


Sign in / Sign up

Export Citation Format

Share Document