scholarly journals Elastography in predicting preterm delivery in asymptomatic, low-risk women: a prospective observational study

2014 ◽  
Vol 14 (1) ◽  
Author(s):  
Slawomir Wozniak ◽  
Piotr Czuczwar ◽  
Piotr Szkodziak ◽  
Pawel Milart ◽  
Ewa Wozniakowska ◽  
...  
2015 ◽  
Vol 86 (6) ◽  
pp. 442-447 ◽  
Author(s):  
Sławomir Woźniak ◽  
Piotr Czuczwar ◽  
Piotr Szkodziak ◽  
Wojciech Wrona ◽  
Tomasz Paszkowski

2020 ◽  
Vol 46 (7) ◽  
pp. 1090-1097
Author(s):  
Kenji Hishikawa ◽  
Takeshi Kusaka ◽  
Takanori Fukuda ◽  
Yutaka Kohata ◽  
Hiromi Inoue

CJEM ◽  
2020 ◽  
Vol 22 (S1) ◽  
pp. S47-S47
Author(s):  
M. Kulas ◽  
L. Brueton-Campbell ◽  
E. Weldon ◽  
N. McDonald ◽  
R. Pryce

Introduction: This was a prospective observational study involving a convenience sample of low-risk trauma patients presenting to a Level 1 Trauma Centre under spinal motion restriction (SMR). To our knowledge no prior studies have objectively measured head-neck (H-N) motion in trauma patients with suspected spine injuries during emergency department (ED) care. The goal was to establish the feasibility of deploying non-invasive motion sensors on trauma patients in the ED and to provide initial estimates for H-N kinematics under SMR during different phases of treatment. Methods: Low-risk adult patients treated by Winnipeg Fire Paramedic Service who sustained non-life threatening trauma with the potential for spine injury were eligible for inclusion. Participants received usual pre-hospital care; application of spine board and/or cervical collar, as determined by local practice protocol. Inertial measurement units (IMUs) were placed on participant's forehead, sternum and stretcher upon arrival to the ED. Data was collected during three phases of care: patient handling (log rolls, transfers, clothing removal); stretcher movement (to imaging, etc); stretcher stationary. IMUs were removed upon disposition decision by the attending physician. IMUs yielded data on H-N motion in terms of linear acceleration (resultant) and angular displacement (rotation + flexion-extension + side-flexion = total). Peak (M +/- SE) displacements and accelerations are reported, with comparisons across treatment phases using repeated measures ANOVA. Results: Eleven patients were enrolled in the study (age: 49 +/- 16 years; Injury Severity Score 13.4 +/- 9.9; female = 2). Substantial H-N motion was observed during ED care. Total H-N displacement (28.6 +/- 3.6 deg) and acceleration (7.8 +/- 1.0 m/s2) were higher during patient handling compared to stretcher moving (13.0 +/- 2.5 deg; 4.6 +/- 0.9 m/s2; p < .05) but not while the stretcher was stationary (18.9 +/- 3.4 deg; 5.4 +/- 1.2 m/s2; p > .06). Similar differences were detected for side-flexion and flexion-extension (p < .05), with peak displacements of 11.4+/-1.5 deg and 14.6 +/- 2.2 deg during patient handling, respectively. Conclusion: IMU use on trauma patients safely described H-N motion kinematics in a small sample of patients with different spectrums of illness during their care in the ED. Future studies utilizing IMUs could inform ED spine motion restriction protocols and compare movement of patients in specific subsets (intoxicated, spinal tenderness, injury severity etc.).


Author(s):  
Sandeep Sethumadhavan P. ◽  
Raju Agarwal ◽  
Jayamol M. Anilkumar ◽  
Anup Ramchandran Pillai

Background: Preterm birth is the leading cause of perinatal morbidity and mortality. Transvaginal sonographic measurement of the cervix is a reliable alternative method for the assessment of cervical length as it allows better quality and more accurate visualization of the uterine cervix. Several studies have reported that cervical assessment on transvaginal sonography may be useful in the prediction of preterm delivery. The objective of this study was to assess cervical length at 20 to 24 weeks of gestation in low risk women and correlate with the gestational age at delivery.Methods: A prospective cohort study conducted in a tertiary care Military Hospital in Pune, India. 354 asymptomatic low risk antenatal women with gestational age of 20 to 24 weeks were studied. Cervical assessment with transvaginal sonography for the measurement of cervical length was performed using a 10 MHz transvaginal probe.Results: 7 percent women delivered preterm. The incidence of short cervix in low risk women was only 0.56%. 100% women with short cervix delivered preterm and, only 6.9% patients who had cervical length more than 25 mm delivered preterm. Cervical length 25 mm has got sensitivity and NPV of 100% and a specificity of 93.46%. However, the PPV was only 8%.Conclusions: The study reported significant inverse relation between short cervix and the occurrence of preterm delivery. Our findings suggest that cervical length can be used as a screening method for preterm labour in low risk women. However strong evidences from large randomized control trials would be required to assess its cost-effectiveness. 


Sign in / Sign up

Export Citation Format

Share Document