scholarly journals Feasibility evaluation of micro-optical coherence tomography (μOCT) for rapid brain tumor type and grade discriminations: μOCT images versus pathology

2019 ◽  
Vol 19 (1) ◽  
Author(s):  
Xiaojun Yu ◽  
Chi Hu ◽  
Wenfei Zhang ◽  
Jie Zhou ◽  
Qianshan Ding ◽  
...  

Abstract Background Precise identification, discrimination and assessment of central nervous system (CNS) tumors is of critical importance to brain neoplasm treatment. Due to the complexity and limited resolutions of the existing diagnostic tools, however, it is difficult to identify the tumors and their boundaries precisely in clinical practice, and thus, the conventional way of brain neoplasm treatment relies mainly on the experiences of neurosurgeons to make resection decisions in the surgery process. The purpose of this study is to explore the potential of Micro-optical coherence tomography (μOCT) as an intraoperative diagnostic imaging tool for identifying and discriminating glioma and meningioma with their microstructure imaging ex vivo, which thus may help neurosurgeons to perform precise surgery with low costs and reduced burdens. Methods Fresh glioma and meningioma samples were resected from patients, and then slices of such samples were excised and imaged instantly ex vivo with a lab-built μOCT, which achieves a spatial resolution of ~ 2.0 μm (μm). The acquired optical coherence tomography (OCT) images were pathologically evaluated and compared to their corresponding histology for both tumor type and tumor grade discriminations in different cases. Results By using the lab-built μOCT, both the cross-sectional and en face images of glioma and meningioma were acquired ex vivo. Based upon the morphology results, both the glioma and meningioma types as well as the glioma grades were assessed and discriminated. Comparisons between OCT imaging results and histology showed that typical tissue microstructures of glioma and meningioma could be clearly identified and confirmed the type and grade discriminations with satisfactory accuracy. Conclusions μOCT could provide high-resolution three-dimensional (3D) imaging of the glioma and meningioma tissue microstructures rapidly ex vivo. μOCT imaging results could help discriminate both tumor types and grades, which illustrates the potential of μOCT as an intraoperative diagnostic imaging tool to help neurosurgeons perform their surgery precisely in tumor treatment process.

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
R Bhoite ◽  
H Jinnouchi ◽  
F Otsuka ◽  
Y Sato ◽  
A Sakamoto ◽  
...  

Abstract Background In many studies, struts coverage is defined as >0 mm of tissue overlying the stent struts by optical coherence tomography (OCT). However, this definition has never been validated using histology as the “gold standard”. The present study sought to assess the appropriate cut-off value of neointimal thickness of stent strut coverage by OCT using histology. Methods OCT imaging was performed on 39 human coronary arteries with stents from 25 patients at autopsy. A total of 165 cross-sectional images from 46 stents were co-registered with histology. The optimal cut-off value of strut coverage by OCT was determined. Strut coverage by histology was defined as endothelial cells with at least underlying two layers of smooth muscle cells. Considering the resolution of OCT is 10–20 μm, 3 different cut-off values (i.e. at ≥20, ≥40, and ≥60 μm) were assessed. Results A total of 2235 struts were evaluated by histology. Eventually, 1216 struts which were well-matched struts were analyzed in this study. By histology, uncovered struts were observed in 160 struts and covered struts were observed in 1056 struts. The broadly used definition of OCT-coverage which does not consider neointimal thickness yielded a poor specificity of 37.5% and high sensitivity 100%. Of 3 cut-off values, the cut-off value of >40 μm was more accurate as compared to >20 and >60 mm [sensitivity (99.3%), specificity (91.0%), positive predictive value (98.6%), and negative predictive value (95.6%)] Conclusion The most accurate cut-off value was ≥40 μm neointimal thickness by OCT in order to identify stent strut coverage validated by histology. Funding Acknowledgement Type of funding source: None


Author(s):  
Matthias Grimm ◽  
Hessam Roodaki ◽  
Abouzar Eslami ◽  
Nassir Navab

Abstract Purpose Intraoperative optical coherence tomography (iOCT) was recently introduced as a new modality for ophthalmic surgeries. It provides real-time cross-sectional information at a very high resolution. However, properly positioning the scan location during surgery is cumbersome and time-consuming, as a surgeon needs both his hands for surgery. The goal of the present study is to present a method to automatically position an iOCT scan on an anatomy of interest in the context of anterior segment surgeries. Methods First, a voice recognition algorithm using a context-free grammar is used to obtain the desired pose from the surgeon. Then, the limbus circle is detected in the microscope image and the iOCT scan is placed accordingly in the X–Y plane. Next, an iOCT sweep in Z direction is conducted and the scan is placed to centre the topmost structure. Finally, the position is fine-tuned using semantic segmentation and a rule-based system. Results The logic to position the scan location on various anatomies was evaluated on ex vivo porcine eyes (10 eyes for corneal apex and 7 eyes for cornea, sclera and iris). The mean euclidean distances (± standard deviation) was 76.7 (± 59.2) pixels and 0.298 (± 0.229) mm. The mean execution time (± standard deviation) in seconds for the four anatomies was 15 (± 1.2). The scans have a size of 1024 by 1024 pixels. The method was implemented on a Carl Zeiss OPMI LUMERA 700 with RESCAN 700. Conclusion The present study introduces a method to fully automatically position an iOCT scanner. Providing the possibility of changing the OCT scan location via voice commands removes the burden of manual device manipulation from surgeons. This in turn allows them to keep their focus on the surgical task at hand and therefore increase the acceptance of iOCT in the operating room.


2017 ◽  
Vol 2017 ◽  
pp. 1-20 ◽  
Author(s):  
Mobin Ibne Mokbul

Optical coherence tomography is a micrometer-scale imaging modality that permits label-free, cross-sectional imaging of biological tissue microstructure using tissue backscattering properties. After its invention in the 1990s, OCT is now being widely used in several branches of neuroscience as well as other fields of biomedical science. This review study reports an overview of OCT’s applications in several branches or subbranches of neuroscience such as neuroimaging, neurology, neurosurgery, neuropathology, and neuroembryology. This study has briefly summarized the recent applications of OCT in neuroscience research, including a comparison, and provides a discussion of the remaining challenges and opportunities in addition to future directions. The chief aim of the review study is to draw the attention of a broad neuroscience community in order to maximize the applications of OCT in other branches of neuroscience too, and the study may also serve as a benchmark for future OCT-based neuroscience research. Despite some limitations, OCT proves to be a useful imaging tool in both basic and clinical neuroscience research.


The Analyst ◽  
2020 ◽  
Vol 145 (4) ◽  
pp. 1445-1456 ◽  
Author(s):  
Fabian Placzek ◽  
Eliana Cordero Bautista ◽  
Simon Kretschmer ◽  
Lara M. Wurster ◽  
Florian Knorr ◽  
...  

Characterization of bladder biopsies, using a combined fiber optic probe-based optical coherence tomography and Raman spectroscopy imaging system that allows a large field-of-view imaging and detection and grading of cancerous bladder lesions.


Author(s):  
Anna Lentzsch ◽  
Laura Schöllhorn ◽  
Christel Schnorr ◽  
Robert Siggel ◽  
Sandra Liakopoulos

Abstract Purpose To compare swept-source (SS) versus spectral-domain (SD) optical coherence tomography angiography (OCTA) for the detection of macular neovascularization (MNV). Methods In this prospective cohort study, 72 eyes of 54 patients with subretinal hyperreflective material (SHRM) and/or pigment epithelial detachment (PED) on OCT possibly corresponding to MNV in at least one eye were included. OCTA scans were acquired using two devices, the PLEX Elite 9000 SS-OCTA and the Spectralis SD-OCTA. Fluorescein angiography (FA) was used as reference. Two graders independently evaluated en face OCTA images using a preset slab as well as a manually modified slab, followed by a combination of en face and cross-sectional OCTA. Results Sensitivity (specificity) for the automated slabs was 51.7% (93.0%) for SS-OCTA versus 58.6% (95.3%) for SD-OCTA. Manual modification of segmentation increased sensitivity to 79.3% for SS-OCTA but not for SD-OCTA (58.6%). The combination of en face OCTA with cross-sectional OCTA reached highest sensitivity values (SS-OCTA: 82.8%, SD-OCTA: 86.2%), and lowest number of cases with discrepancies between SS-OCTA and SD-OCTA (4.2%). Fleiss kappa as measure of concordance between FA, SS-OCTA, and SD-OCTA was 0.56 for the automated slabs, 0.60 for the manual slabs, and 0.73 (good agreement) for the combination of en face OCTA with cross-sectional OCTA. Concordance to FA was moderate for the automated slabs and good for manual slabs and combination with cross-sectional OCTA of both devices. Conclusion Both devices reached comparable results regarding the detection of MNV on OCTA. Sensitivity for MNV detection and agreement between devices was best when evaluating a combination of en face and cross-sectional OCTA.


2021 ◽  
Vol 127 (4) ◽  
Author(s):  
S. Skruszewicz ◽  
S. Fuchs ◽  
J. J. Abel ◽  
J. Nathanael ◽  
J. Reinhard ◽  
...  

AbstractWe present an overview of recent results on optical coherence tomography with the use of extreme ultraviolet and soft X-ray radiation (XCT). XCT is a cross-sectional imaging method that has emerged as a derivative of optical coherence tomography (OCT). In contrast to OCT, which typically uses near-infrared light, XCT utilizes broad bandwidth extreme ultraviolet (XUV) and soft X-ray (SXR) radiation (Fuchs et al in Sci Rep 6:20658, 2016). As in OCT, XCT’s axial resolution only scales with the coherence length of the light source. Thus, an axial resolution down to the nanometer range can be achieved. This is an improvement of up to three orders of magnitude in comparison to OCT. XCT measures the reflected spectrum in a common-path interferometric setup to retrieve the axial structure of nanometer-sized samples. The technique has been demonstrated with broad bandwidth XUV/SXR radiation from synchrotron facilities and recently with compact laboratory-based laser-driven sources. Axial resolutions down to 2.2 nm have been achieved experimentally. XCT has potential applications in three-dimensional imaging of silicon-based semiconductors, lithography masks, and layered structures like XUV mirrors and solar cells.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Hayoung Byun ◽  
Yeon Hoon Kim ◽  
Jingchao Xing ◽  
Su-Jin Shin ◽  
Seung Hwan Lee ◽  
...  

AbstractImaging the Eustachian tube is challenging because of its complex anatomy and limited accessibility. This study fabricated a fiber-based optical coherence tomography (OCT) catheter and investigated its potential for assessing the Eustachian tube anatomy. A customized OCT system and an imaging catheter, termed the Eustachian OCT, were developed for visualizing the Eustachian tube. Three male swine cadaver heads were used to study OCT image acquisition and for subsequent histologic correlation. The imaging catheter was introduced through the nasopharyngeal opening and reached toward the middle ear. The OCT images were acquired from the superior to the nasopharyngeal opening before and after Eustachian tube balloon dilatation. The histological anatomy of the Eustachian tube was compared with corresponding OCT images, The new, Eustachian OCT catheter was successfully inserted in the tubal lumen without damage. Cross-sectional images of the tube were successfully obtained, and the margins of the anatomical structures including cartilage, mucosa lining, and fat could be successfully delineated. After balloon dilatation, the expansion of the cross-sectional area could be identified from the OCT images. Using the OCT technique to assess the Eustachian tube anatomy was shown to be feasible, and the fabricated OCT image catheter was determined to be suitable for Eustachian tube assessment.


2018 ◽  
Vol 10 (1) ◽  
pp. 39-46 ◽  
Author(s):  
Sharad Gupta ◽  
Dev Narayan Shah ◽  
Sagun Narayan Joshi ◽  
Manoj Aryal ◽  
Lila Raj Puri

Aim: The aim of the study is to classify the patterns of uveitic macular edema using Optical Coherence Tomography as a diagnostic tool.Methodology: It is the Descriptive, cross-sectional study. All patients fulfilling the diagnostic criteria with Optical coherence tomography diagnosed macular edema were enrolled from 1 January 2012 to 30 June 2013. Patterns of uveitic macular edema were classified.Results: A total of 65 eyes of 47 patients were included. Twenty eight (59.57%) were male. The male to female ratio was 1.5:1. The mean age was 38 years (SD 14.68). Twenty nine patients (61.71%) had unilateral involvement and 18 (38.29%) had bilateral involvement. Forty five eyes of 33 cases (69.23%, 70.21%) had intermediate uveitis, followed by 10 eyes of 7 cases (15.38, 14.9%) of posterior uveitis, 6 eyes of 5 cases (9.23%, 10.63 %) of anterior uveitis and 4 eyes of 2 cases (6.16%,4.2%) of pan-uveitis. Patterns of macular edema were classified: diff use macular edema (DME), cystoid macular edema (CME) and serous retinal detachment (SRD) of which 35 (53.84%) eyes had CME. The etiological diagnosis was found in 7(14.90 %) out of 47 patients.Conclusion: A significant percentage of cases were idiopathic. Macular edema may go unnoticed unless OCT is performed. Macular detachment is an important feature of macular edema that affects visual acuity and is not readily detected by Fundus Fluorescein Angiography (FFA). Optical coherence tomography (OCT) is safe and non-invasive technique and has the potential for measuring changes in retinal thickness and axial extent of edema.