scholarly journals Handrub dispensers per acute care hospital bed: a study to develop a new minimum standard

Author(s):  
Sabine Kuster ◽  
Jan A. Roth ◽  
Reno Frei ◽  
Christoph A. Meier ◽  
Marc Dangel ◽  
...  

Abstract Background Accessibility to alcohol-based handrub (ABHR) dispenser is crucial to improve compliance to hand hygiene (HH), being offered as wall-mounted dispensers (ABHR-Ds), and/or pocket bottles. Nevertheless, information on the distribution and density of ABHR-Ds and their impact on HH have hardly been studied. Institutions such as the World Health Organisation or the Centers for Disease Control and Prevention do not provide guidance. The Robert-Koch-Institute (RKI) from Germany recommends an overall density of > 0.5 dispensers per patient bed. We aimed to investigate current conditions in hospitals to develop a standard on the minimal number of ABHR-D. Methods Between 07 and 09/2019, we applied a questionnaire to 178 hospitals participating in the Swissnoso National Surveillance Network to evaluate number and location of ABHR-Ds per bed in acute care hospitals, and compared the data with consumption and compliance with HH. Results 110 of the 178 (62%) hospitals provided data representing approximately 20,000 hospital beds. 83% hospitals provided information on both the total number of ABHR-Ds and patient beds, with a mean of 2.4 ABHR-Ds per bed (range, 0.4–22.1). While most hospitals (84%) had dispensers located at the room entrance, 47% reported also locations near or at the bed. Additionally, pocket-sized dispensers (100 mL) are available in 97% of hospitals. Conclusions Swiss hospitals provide 2.4 dispensers per bed, much more than governmental recommendation. The first study on the number of ABHR-Ds in hospitals may help to define a minimal standard for national and international recommendations

2009 ◽  
Vol 30 (4) ◽  
pp. 319-324 ◽  
Author(s):  
Allan J. Walkey ◽  
Christine Campbell Reardon ◽  
Carol A. Sulis ◽  
R. Nicholas Nace ◽  
Martin Joyce-Brady

Objective.To characterize the epidemiology and microbiology of ventilator-associated pneumonia (VAP) in a long-term acute care hospital (LTACH).Design.Retrospective study of prospectively identified cases of VAP.Setting.Single-center, 207-bed LTACH with the capacity to house 42 patients requiring mechanical ventilation, evaluated from April 1, 2006, through January 31, 2008.Methods.Data on the occurrence of VAP were collected prospectively as part of routine infection surveillance at Radius Specialty Hospital. After March 2006, Radius Specialty Hospital implemented a bundle of interventions for the prevention of VAP (hereafter referred to as the VAP-bundle approach). A case of VAP was defined as a patient who required mechanical ventilation at Radius Specialty Hospital for at least 48 hours before any symptoms of pneumonia appeared and who met the Centers for Disease Control and Prevention criteria for VAP. Sputum samples were collected from a tracheal aspirate if there was clinical suspicion of VAP, and these samples were semi-quantitatively cultured.Results.During the 22-month study period, 23 cases of VAP involving 19 patients were associated with 157 LTACH admissions (infection rate, 14.6%), corresponding to a rate of 1.67 cases per 1,000 ventilator-days, which is a 56% reduction from the VAP rate of 3.8 cases per 1,000 ventilator-days reported before the implementation of the VAP-bundle approach (P<.001). Microbiological data were available for 21 (91%) of 23 cases of VAP. Cases of VAP in the LTACH were frequently polymicrobial (mean number ± SD, 1.78 ± 1.0 pathogens per case of VAP), and 20 (95%) of 21 cases of VAP had at least 1 pathogen (Pseudomonas species, Acinetobacter species, gram-negative bacilli resistant to more than 3 antibiotics, or methicillin-resistant Staphylococcus aureus) cultured from a sputum sample. LTACH patients with VAP were more likely to have a neurological reason for ventilator dependence, compared with LTACH patients without VAP (69.6% of cases of VAP vs 39% of cases of respiratory failure; P = .014). In addition, patients with VAP had a longer length of LTACH stay, compared with patients without VAP (median length of stay, 131 days vs 39 days; P = .002). In 6 (26%) of 23 cases of VAP, the patient was eventually weaned from use of mechanical ventilation. Of the 19 patients with VAP, 1 (5%) did not survive the LTACH stay.Conclusions.The VAP rate in the LTACH is lower than the VAP rate reported in acute care hospitals. Cases of VAP in the LTACH were frequently polymicrobial and were associated with multidrug-resistant pathogens and increased length of stay. The guidelines from the Centers for Disease Control and Prevention that are aimed at reducing cases of VAP appear to be effective if applied in the LTACH setting.


2017 ◽  
Vol 1 (1) ◽  
Author(s):  
Sinha Chandni Sen ◽  
LaSalle Colette ◽  
Argabright Debra ◽  
Hollenbeck Clarie B

2021 ◽  
pp. 1-7
Author(s):  
Martina Madl ◽  
Marietta Lieb ◽  
Katharina Schieber ◽  
Tobias Hepp ◽  
Yesim Erim

<b><i>Background:</i></b> Due to the establishment of a nationwide certification system for cancer centers in Germany, the availability of psycho-oncological services for cancer patients has increased substantially. However, little is known about the specific intervention techniques that are applied during sessions in an acute care hospital, since a standardized taxonomy is lacking. With this study, we aimed at the investigation of psycho-oncological intervention techniques and the development of a comprehensive and structured taxonomy thereof. <b><i>Methods:</i></b> In a stepwise procedure, a team of psycho-oncologists generated a data pool of interventions and definitions that were tested in clinical practice during a pilot phase. After an adaptation of intervention techniques, interrater reliability (IRR) was attained by rating 10 previously recorded psycho-oncological sessions. A classification of interventions into superordinate categories was performed, supported by cluster analysis. <b><i>Results:</i></b> Between April and June 2017, 980 psycho-oncological sessions took place. The experts agreed on a total number of 22 intervention techniques. An IRR of 89% for 2 independent psycho-oncological raters was reached. The 22 techniques were classified into 5 superordinate categories. <b><i>Discussion/Conclusion:</i></b> We developed a comprehensive and structured taxonomy of psycho-oncological intervention techniques in an acute care hospital that provides a standardized basis for systematic research and applied care. We expect our work to be continuously subjected to further development: future research should evaluate and expand our taxonomy to other contexts and care settings.


Author(s):  
Mª José Calero-García ◽  
Alfonso J. Cruz Lendínez

The first objective of this research is to establish and study how the different stages of cognitive impairment and the levels of dependence evolve in patients over 65 years of age, admitted to an acute care hospital, as well as the relationship between these factors and the different social and demographical variables. The results show that the level of dependence decreases suddenly at the time of admission and undergoes a slight recovery at the time of discharge. Although this recovery continues at home after discharge, patients do not get the same level of independence that they used to have before admission. In addition, significant differences in terms of age, marital status and education level were found. In general, our results show that elderly men over 80 years of age, without no education and widowers are more likely to suffer from severe cognitive impairment and be more functionally dependent when admitted to hospital.