Test-retest Reliability Of Vertical Jump Performance In Competitive Cross Country Skiers

2011 ◽  
Vol 43 (Suppl 1) ◽  
pp. 8
Author(s):  
Katelyn Taylor ◽  
Sarah J. Willis ◽  
Daniel P. Heil
Author(s):  
Špela Bogataj ◽  
Maja Pajek ◽  
Vedran Hadžić ◽  
Slobodan Andrašić ◽  
Johnny Padulo ◽  
...  

There is a persistent need in sport science for developing a measuring tool that is affordable, portable, and easy to use. We aimed to examine the concurrent validity and test–retest reliability of the My Jump 2 app compared to a validated OptoJump instrument for measuring jump performance during the squat jump (SJ), countermovement jump (CMJ), and CMJ free arms (CMJAM) in primary school children. A total of 48 participants (11–14 years age), volunteered to participate in this research. The jumps were recorded with a validated OptoJump photoelectric cell system and a concurrent device (iPhone X through My Jump 2 app) at the same time. The participants repeated the testing procedure after two weeks to assess the reliability of the measurements (ICC). Systematic bias between sessions and tools was evaluated using the paired samples t-test and Bland and Altman analysis. High test–retest reliability (ICC > 0.89) was observed for all measures’ in-between conditions. Very large correlations in the total sample were observed between the My Jump 2 app and OptoJump for SJ (r = 0.97, p = 0.001), CMJ (r = 0.97, p = 0.001), and CMJAM (r = 0.99, p = 0.001). Bland and Altman’s plot depicting limits of agreement for the total sample between the OptoJump and My Jump 2 show that the majority of data points are within the 95% CIs. The results of this study suggest that My Jump 2 is a valid, reliable, and useful tool for measuring jump performance in primary school children.


2017 ◽  
Vol 60 (1) ◽  
pp. 9-18 ◽  
Author(s):  
Glenn Björklund ◽  
Marie Alricsson ◽  
Ulla Svantesson

AbstractThe aim of this study was to evaluate the symmetry of anthropometry and muscle function in cross-country skiers and their association to vertical jumping power. Twenty cross-country skiers were recruited (21.7 ± 3.8 yrs, 180.6 ± 7.6 cm, 73.2 ± 7.6 kg). Anthropometric data was obtained using an iDXA scan. VO2maxwas determined using the diagonal stride technique on a ski treadmill. Bilateral functional tests for the upper and lower body were the handgrip and standing heel-rise tests. Vertical jump height and power were assessed with a counter movement jump. Percent asymmetry was calculated using a symmetry index and four absolute symmetry index levels. At a group level the upper body was more asymmetrical with regard to lean muscle mass (p = 0.022, d = 0.17) and functional strength (p = 0.019, d = 0.51) than the lower body. At an individual level the expected frequencies for absolute symmetry level indexes showed the largest deviation from zero for the heel-rise test (χ2 = 16.97, p = 0.001), while the leg lean mass deviated the least (χ2 = 0.42, p = 0.517). No relationships were observed between absolute symmetry level indexes of the lower body and counter movement jump performance (p > 0.05). As a group the skiers display a more asymmetrical upper body than lower body regarding muscle mass and strength. Interestingly at the individual level, despite symmetrical lean leg muscle mass the heel-rise test showed the largest asymmetry. This finding indicates a mismatch in muscle function for the lower body.


2020 ◽  
Vol 10 (11) ◽  
pp. 3805 ◽  
Author(s):  
Špela Bogataj ◽  
Maja Pajek ◽  
Slobodan Andrašić ◽  
Nebojša Trajković

This study aimed to examine the reliability, validity, and usefulness of the smartphone-based application, My Jump 2, against Optojump in recreationally active adults. Participants (18 women, 28.9 ± 5.6 years, and 26 men, 30.1 ± 10.6 years) completed squat jumps (SJ), counter-movement jumps (CMJ), and CMJ with arm swing (CMJAS) on Optojump and were simultaneously recorded using My Jump 2. To evaluate concurrent validity, jump height, calculated from flight time attained from each device, was compared for each jump type. Test-retest reliability was determined by replicating data analysis of My Jump 2 recordings on two occasions separated by two weeks. High test-retest reliability (Intraclass correlation coefficient (ICC) > 0.93) was observed for all measures in both male and female athletes. Very large correlations were observed between the My Jump 2 app and Optojump for SJ (r = 0.95, p = 0.001), CMJ (r = 0.98, p = 0.001), and CMJAS (r = 0.98, p = 0.001) in male athletes. Similar results were obtained for female recreational athletes for all jumps (r > 0.94, p = 0.001). The study results suggest that My Jump 2 is a valid, reliable, and useful tool for measuring vertical jump in recreationally active adults. Therefore, due to its simplicity and practicality, it can be used by practitioners, coaches, and recreationally-active adults to measure vertical jump performance with a simple test as SJ, CMJ, and CMJAS.


2017 ◽  
Vol 49 (5S) ◽  
pp. 1082
Author(s):  
Brianna D. McKay ◽  
Amelia A. Miramonti ◽  
Nathaniel D.M. Jenkins ◽  
Zachary Gillen ◽  
Todd J. Leutzinger

Author(s):  
Matthew L. Hall ◽  
Stephanie De Anda

Purpose The purposes of this study were (a) to introduce “language access profiles” as a viable alternative construct to “communication mode” for describing experience with language input during early childhood for deaf and hard-of-hearing (DHH) children; (b) to describe the development of a new tool for measuring DHH children's language access profiles during infancy and toddlerhood; and (c) to evaluate the novelty, reliability, and validity of this tool. Method We adapted an existing retrospective parent report measure of early language experience (the Language Exposure Assessment Tool) to make it suitable for use with DHH populations. We administered the adapted instrument (DHH Language Exposure Assessment Tool [D-LEAT]) to the caregivers of 105 DHH children aged 12 years and younger. To measure convergent validity, we also administered another novel instrument: the Language Access Profile Tool. To measure test–retest reliability, half of the participants were interviewed again after 1 month. We identified groups of children with similar language access profiles by using hierarchical cluster analysis. Results The D-LEAT revealed DHH children's diverse experiences with access to language during infancy and toddlerhood. Cluster analysis groupings were markedly different from those derived from more traditional grouping rules (e.g., communication modes). Test–retest reliability was good, especially for the same-interviewer condition. Content, convergent, and face validity were strong. Conclusions To optimize DHH children's developmental potential, stakeholders who work at the individual and population levels would benefit from replacing communication mode with language access profiles. The D-LEAT is the first tool that aims to measure this novel construct. Despite limitations that future work aims to address, the present results demonstrate that the D-LEAT represents progress over the status quo.


1982 ◽  
Vol 25 (4) ◽  
pp. 521-527 ◽  
Author(s):  
David C. Shepherd

In 1977, Shepherd and colleagues reported significant correlations (–.90, –.91) between speechreading scores and the latency of a selected negative peak (VN 130 measure) on the averaged visual electroencephalic wave form. The primary purpose of this current study was to examine the stability, or repeatability, of this relation between these cognitive and neurophysiologic measures over a period of several months and thus support its test-retest reliability. Repeated speechreading word and sentence scores were gathered during three test-retest sessions from each of 20 normal-hearing adults. An average of 56 days occurred from the end of one to the beginning of another speechreading sessions. During each of four other test-retest sessions, averaged visual electroencephalic responses (AVER s ) were evoked from each subject. An average of 49 clays intervened between AVER sessions. Product-moment correlations computed among repeated word scores and VN l30 measures ranged from –.61 to –.89. Based on these findings, it was concluded that the VN l30 measure of visual neural firing time is a reliable correlate of speech-reading in normal-hearing adults.


2000 ◽  
Vol 16 (1) ◽  
pp. 53-58 ◽  
Author(s):  
Hans Ottosson ◽  
Martin Grann ◽  
Gunnar Kullgren

Summary: Short-term stability or test-retest reliability of self-reported personality traits is likely to be biased if the respondent is affected by a depressive or anxiety state. However, in some studies, DSM-oriented self-reported instruments have proved to be reasonably stable in the short term, regardless of co-occurring depressive or anxiety disorders. In the present study, we examined the short-term test-retest reliability of a new self-report questionnaire for personality disorder diagnosis (DIP-Q) on a clinical sample of 30 individuals, having either a depressive, an anxiety, or no axis-I disorder. Test-retest scorings from subjects with depressive disorders were mostly unstable, with a significant change in fulfilled criteria between entry and retest for three out of ten personality disorders: borderline, avoidant and obsessive-compulsive personality disorder. Scorings from subjects with anxiety disorders were unstable only for cluster C and dependent personality disorder items. In the absence of co-morbid depressive or anxiety disorders, mean dimensional scores of DIP-Q showed no significant differences between entry and retest. Overall, the effect from state on trait scorings was moderate, and it is concluded that test-retest reliability for DIP-Q is acceptable.


2013 ◽  
Author(s):  
Kristen M. Dahlin-James ◽  
Emily J. Hennrich ◽  
E. Grace Verbeck-Priest ◽  
Jan E. Estrellado ◽  
Jessica M. Stevens ◽  
...  

2018 ◽  
Vol 30 (12) ◽  
pp. 1652-1662 ◽  
Author(s):  
Sophie J. M. Rijnen ◽  
Sophie D. van der Linden ◽  
Wilco H. M. Emons ◽  
Margriet M. Sitskoorn ◽  
Karin Gehring

Sign in / Sign up

Export Citation Format

Share Document