Prediction of the Effective Thermal Conductivity of the In-Gap Particle Layer of Heat Exchanger Tubes with Wastage Covers in a Pressurized Fluidized Bed

2006 ◽  
Vol 32 (3) ◽  
pp. 246-252 ◽  
Author(s):  
Taro Sakata ◽  
Tetsuya Iwase ◽  
Shinji Kambara ◽  
Hiroshi Moritomi
2017 ◽  
Vol 25 (01) ◽  
pp. 1750006 ◽  
Author(s):  
Keun Sun Chang ◽  
Min Jun Kim ◽  
Young Jae Kim

In recent years, application of the standing column well (SCW) ground heat exchanger (GHX) has been noticeably increased as a heat transfer mechanism of ground source heat pump (GSHP) systems with its high heat capacity and efficiency. Determination of the ground thermal properties is an important task for sizing and estimating cost of the GHX. In this study, an in situ thermal response test (TRT) is applied to the thermal performance evaluation of SCW. Two SCWs with different design configurations are installed in sequence to evaluate their effects on the thermal performance of SCW using a single borehole. A line source method is used to derive the effective thermal conductivity and borehole thermal resistance. Effects of operating parameters are also investigated including bleed, heat injection rate, flow rate and filler height. Results show that the effective thermal conductivity of top drawn SCW (Type A) is 11.7% higher than that of bottom drawn SCW (Type B) and of operating parameters tested bleed is the most significant one for the improvement of the thermal performance (40.4% enhanced in thermal conductivity with 10.9% bleed).


Energies ◽  
2020 ◽  
Vol 13 (14) ◽  
pp. 3737
Author(s):  
Aneta Sapińska-Śliwa ◽  
Tomasz Sliwa ◽  
Kazimierz Twardowski ◽  
Krzysztof Szymski ◽  
Andrzej Gonet ◽  
...  

This work concerns borehole heat exchangers and their testing using apparatus for thermal response tests. In the theoretical part of the article, an equation was derived from the known equation of heat flow, on which the interpretation of the thermal response test was based. The practical part presents the results of several measurements taken in the AGH Laboratory of Geoenergetics. They were aimed at examining the potential heat exchange capacity between the heat carrier and rock mass. Measurement results in the form of graphs are shown in relation to the examined, briefly described wells. Result analysis made it possible to draw conclusions regarding the interpretation of the thermal response test. The method of averaging the measurement results was subjected to further study. The measuring apparatus recorded data at a frequency of one second, however such accuracy was too large to be analyzed efficiently. Therefore, an average of every 1 min, every 10 min, and every 60 min was proposed. The conclusions stemming from the differences in the values of effective thermal conductivity in the borehole heat exchanger, resulting from different data averaging, were described. In the case of three borehole heat exchangers, ground properties were identical. The effective thermal conductivity λeff was shown to depend on various borehole heat exchanger (BHE) designs, heat carrier flow geometry, and grout parameters. It is important to consider the position of the pipes relative to each other. As shown in the charts, the best (the highest) effective thermal conductivity λeff occurred in BHE-1 with a coaxial construction. At the same time, this value was closest to the theoretical value of thermal conductivity of rocks λ, determined on the basis of literature. The standard deviation and the coefficient of variation confirmed that the effective thermal conductivity λeff, calculated for different time intervals, showed little variation in value. The values of effective thermal conductivity λeff for each time interval for the same borehole exchanger were similar in value. The lowest values of effective thermal conductivity λeff most often appeared for analysis with averaging every 60 min, and the highest—for analysis with averaging every 1 min. For safety reasons, when designing (number of BHEs), safer values should be taken for analysis, i.e., lower, averaging every 60 min.


2020 ◽  
Vol 12 (24) ◽  
pp. 10445
Author(s):  
Myungkwan Lim ◽  
Kyoungbin Lim ◽  
Changhee Lee

This study proposed a technology to improve the performance characteristics and coefficient of performance (COP) of a geothermal system by fundamentally preventing underground water discharge and maintaining a constant temperature of the underground heat exchanger composed of bleed discharge water that utilizes two balancing wells using cross-mixing methods. Using the standing column well (SCW) and cross-mixing balancing well underground heat exchanger, we compared and analyzed the effective thermal conductivity characteristics and COP characteristics during heating and cooling modes. Consequently, the cross-mixing balancing well underground heat exchanger exhibited more effective thermal conductivity than the SCW underground heat exchanger, with a high COP. Therefore, suggesting the performance was improved using groundwater flow rather than SCW. The comparison and analysis results of the effective heat map characteristics using the results of the SCW and balancing well system showed that the heating operation for the SCW underground heat exchanger had better thermal conductivity characteristics than the cooling operation. In addition, regarding a balancing well underground heat exchanger, the cooling operation exhibited superior thermal conductivity characteristics. Thus, the performance was considered to have improved due to the flow of activated groundwater in the ground and the rapid heat transfer without heat accumulation.


1982 ◽  
Vol 15 (1) ◽  
pp. 39-44 ◽  
Author(s):  
KUNIO KATO ◽  
TAKASHI TAKAHASHI ◽  
TOSHIYUKI KOBAYASHI ◽  
KATUMI KOMAGATA

2020 ◽  
Vol 142 (9) ◽  
Author(s):  
Zihao Zheng ◽  
Xiaohui Bai ◽  
Fujio Kuwahara ◽  
Akira Nakayama

Abstract An octet-truss structure is considered as one of promising candidates for modern heat exchanger structures due to its light weight with stress supporting structure and high thermal performance as a multifunctional heat exchanger. A design strategy has been established to control the anisotropy of its effective thermal conductivity tensor by deforming the structure according to its specific heat transfer application. The solution surface of flat triangle was constructed in the space with three coordinate axes being the principal components of the effective thermal conductivity, using the analytical expressions derived for metal frame structures of low solidity. The design parameters of two structural angles can readily be found from this analytical solution surface with equal angle lines to transfer heat in a particular direction, or to block heat in any other direction. Full three-dimensional (3D) numerical computations were also conducted to verify the validity of the present analytical strategy.


2019 ◽  
pp. 308-308
Author(s):  
Zhong-Bin Zhang ◽  
C Congyu ◽  
Yang Liu ◽  
Li-Hua Cao

The accurate thermal conductivity of fouling plays a very significant role in designing heat exchanger. In this paper, a novel method of calculating the effective thermal conductivity (ETC) of particulate fouling is put forward by using Image-Pro-Plus image processing, the finite element method and ANSYS parametric design language (APDL). First of all, according to the analysis on the particulate fouling samples features, the particulate fouling is considered as porous media with fractal characteristics, whose microscopic network model is established using the finite element method, and each unit body material properties are randomly assigned by APDL. Secondly, ETC of particulate fouling model is calculated by the steady state plate method. And then, the influence of particulate fouling microstructure on ETC is explored. Last, it is also show that the calculation resulting of ETC agrees well with available experimental data and empirical correlation. Moreover, it has been shown that ETC of particulate fouling is closely associated with the porosity and pore size. The method can be used to research on the thermal conductivity of fouling, discuss the influence of microstructure on ETC of fouling, and provide the guidelines for designing of heat exchanger on calculating accurate thermal conductivity of fouling.


2005 ◽  
Vol 73 (1) ◽  
pp. 60-65 ◽  
Author(s):  
Nadia Allouache ◽  
Salah Chikh

A combination of the first and second laws of thermodynamics has been utilized in analyzing the performance of a double pipe heat exchanger with a porous medium attached over the inner pipe. The goal of this work is to find the best conditions that allow the lowest rate of entropy generation due to fluid friction and heat transfer with respect to the considered parameters. Results show that the minimization of the rate of entropy generation depends on the porous layer thickness, its permeability, the inlet temperature difference between the two fluids, and the effective thermal conductivity of the porous substrate. An increase in the effective thermal conductivity of the porous medium seems to be thermodynamically advantageous. Unexpectedly, the fully porous annular gap yields the best results in terms of the rate of total entropy generation.


Sign in / Sign up

Export Citation Format

Share Document