Fuel distribution visualization from an air-assisted injector in a spray chamber using LIF, MIE, Direct imaging and PDA(Measurement, Species)

Author(s):  
M. Skogsberg ◽  
P. Dahlander ◽  
F. Persson ◽  
S. Hemdal ◽  
I. Denbratt
1995 ◽  
Vol 167 ◽  
pp. 3-7
Author(s):  
A. G. Davis Philip

A short introduction to the subject of the meeting, IAU Symposium No. 167, New Developments in Array Technology and Applications is given. CCD and Array detectors have become the detectors of choice at optical observatories all over the world. Direct imaging, photometry and spectroscopy are all vastly improved as a result. Thirteen IAU Commissions joined in sponsoring this meeting which indicates the wide interest in this subject. In the five days of the symposium the following topics were discussed: New Developments in CCD Technology, New Developments in IR Detector Arrays, Direct Imaging with CCDs and Other Arrays, Spectroscopy with CCDs and Other Arrays and Large Field Imaging with Array Mosaics. A few papers concerning Astrometry with CCDs were given in the poster sessions. Scientific results were also presented in the poster sessions.


Pharmaceutics ◽  
2021 ◽  
Vol 13 (5) ◽  
pp. 746
Author(s):  
Magdalena Turk ◽  
Rok Šibanc ◽  
Rok Dreu ◽  
Maja Frankiewicz ◽  
Małgorzata Sznitowska

This study concerned the quality of mini-tablets’ coating uniformity obtained by either the bottom spray chamber with a classical Wurster distributor (CW) or a swirl distributor (SW). Mini-tablets with a diameter of 2.0, 2.5, and 3.0 mm were coated with hypromellose using two different inlet air distributors as well as inlet airflow rates (130 and 156 m3/h). Tartrazine was used as a colorant in the coating layer and the coating uniformity was assessed by spectrophotometric analysis of solutions obtained after disintegration of the mini-tablets (n = 100). Higher uniformity of coating material distribution among the mini-tablets was observed in the case of SW distributor, even for the biggest mini-tablets (d = 3.0 mm), with an RSD no larger than 5.0%. Additionally, coating thickness was evaluated by colorimetric analysis (n = 1000), using a scanner method, and expressed as a hue value. A high correlation (R = 0.993) between inter-tablet variability of hue and UV-Vis results was obtained. Mini-tablets were successfully coated in a fluid bed system using both a classical Wurster distributor as well as a swirl generator. However, regardless of the mini-tablets’ diameter, better film uniformity was achieved in the case of a distributor with a swirl generator.


2021 ◽  
Vol 27 (S1) ◽  
pp. 2724-2726
Author(s):  
Weixin Song ◽  
Miguel Osorio ◽  
John Marie ◽  
Emanuela Liberti ◽  
Xiaonan Luo ◽  
...  

Author(s):  
Bo Wang ◽  
Chi Zhang ◽  
Yuzhen Lin ◽  
Xin Hui ◽  
Jibao Li

In order to balance the low emission and wide stabilization for lean premixed prevaporized (LPP) combustion, the centrally staged layout is preferred in advanced aero-engine combustors. However, compared with the conventional combustor, it is more difficult for the centrally staged combustor to light up as the main stage air layer will prevent the pilot fuel droplets arriving at igniter tip. The goal of the present paper is to study the effect of the main stage air on the ignition of the centrally staged combustor. Two cases of the main swirler vane angle of the TeLESS-II combustor, 20 deg and 30 deg are researched. The ignition results at room inlet temperature and pressure show that the ignition performance of the 30 deg vane angle case is better than that of the 20 deg vane angle case. High-speed camera, planar laser induced fluorescence (PLIF), and computational fluids dynamics (CFD) are used to better understand the ignition results. The high-speed camera has recorded the ignition process, indicated that an initial kernel forms just adjacent the liner wall after the igniter is turned on, the kernel propagates along the radial direction to the combustor center and begins to grow into a big flame, and then it spreads to the exit of the pilot stage, and eventually stabilizes the flame. CFD of the cold flow field coupled with spray field is conducted. A verification of the CFD method has been applied with PLIF measurement, and the simulation results can qualitatively represent the experimental data in terms of fuel distribution. The CFD results show that the radial dimensions of the primary recirculation zone of the two cases are very similar, and the dominant cause of the different ignition results is the vapor distribution of the fuel. The concentration of kerosene vapor of the 30 deg vane angle case is much larger than that of the 20 deg vane angle case close to the igniter tip and along the propagation route of the kernel, therefore, the 30 deg vane angle case has a better ignition performance. For the consideration of the ignition performance, a larger main swirler vane angle of 30 deg is suggested for the better fuel distribution when designing a centrally staged combustor.


2021 ◽  
pp. 125092
Author(s):  
Roberto Matassa ◽  
Maria Sofia Cattaruzza ◽  
Filippo Sandorfi ◽  
Ezio Battaglione ◽  
Michela Relucenti ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document