2412 Effect of Fan Loading on Tip Leakage Vortex in a Semi-open Axial Fan

2006 ◽  
Vol 2006.2 (0) ◽  
pp. 143-144
Author(s):  
Wei Sin SIM ◽  
Norimasa SHIOMI ◽  
Kenji KANEKO ◽  
Naoto SHIMOHARA ◽  
Toshiaki SETOGUCHI
2001 ◽  
Vol 123 (4) ◽  
pp. 748-754 ◽  
Author(s):  
Choon-Man Jang ◽  
Masato Furukawa ◽  
Masahiro Inoue

Three-dimensional structures of the vortical flow field in a propeller fan with a shroud covering only the rear region of its rotor tip have been investigated by experimental analysis using laser Doppler velocimetry (LDV) measurements and by numerical analysis using a large eddy simulation (LES) in Part I of the present study. The propeller fan has a very complicated vortical flow field near the rotor tip compared with axial fan and compressor rotors. It is found that three vortex structures are formed near the rotor tip: the tip vortex, the leading edge separation vortex, and the tip leakage vortex. The tip vortex is so strong that it dominates the flow field near the tip. Its formation starts from the blade tip suction side near the midchord. Even at the design condition the tip vortex convects nearly in the tangential direction, thus impinging on the pressure surface of the adjacent blade. The leading edge separation vortex develops close along the tip suction surface and disappears in the rear region of the rotor passage. The tip leakage vortex is so weak that it does not affect the flow field in the rotor.


2004 ◽  
Vol 2004 (0) ◽  
pp. 9
Author(s):  
Kenji Kaneko ◽  
Kazuyuki Shimozono ◽  
Norimasa Shiomi ◽  
Toshiaki Setouchi

2021 ◽  
Vol 2021 ◽  
pp. 1-24
Author(s):  
Yan Xue ◽  
Ning Ge

In the present paper, the steady RANS (Reynolds-Averaged Navier-Stokes) simulations based on our independently developed CFD (Computational Fluid Dynamics) solver NUAA-Turbo 2.0, are carried out to investigate the shock wave/tip leakage vortex (SW/TLV) interaction in two representative transonic axial fan rotors, NASA Rotor 67 and NASA Rotor 37. The intent of this study is mainly to verify if an identification method derived from relevant theories is suitable for shock-induced vortex stability in the real engineering environment. As the additional findings, a universal tip vortex model is established and the characteristics of vortex breakdown or not are also summarized under different load levels. To ensure the prediction accuracy of all numerical methods selected in this research, detailed comparisons are made between computational and experimental results before flow analysis. The excellent agreement between the both indicates that the current code is capable of capturing the dominant secondary flow structures and aerodynamic phenomenon, especially the vortex system in tip region and SW/TLV interaction. It is found that three vortical structures such as tip leakage vortex (TLV), shock-induced vortex (SIV), tip separation vortex (TSV) in addition the tip leakage vortex-induced vortex (TLV-IV, which only occurs when the TLV strength increases to a certain extent) frequently exist near the blade tip and then abstracted as a tip vortex model. A stable TLV after passing through the passage shock is commonly characterized by tight rolling-up, slow deceleration and slight expansion. Conversely, the vortex behaves in a breakdown state. The final verification results show that the above two vortex states can be satisfactorily detected by the theoretical discriminant introduced in this work.


1997 ◽  
Vol 119 (1) ◽  
pp. 122-128 ◽  
Author(s):  
S. L. Puterbaugh ◽  
W. W. Copenhaver

An experimental investigation concerning tip flow field unsteadiness was performed for a high-performance, state-of-the-art transonic compressor rotor. Casing-mounted high frequency response pressure transducers were used to indicate both the ensemble averaged and time varying flow structure present in the tip region of the rotor at four different operating points at design speed. The ensemble averaged information revealed the shock structure as it evolved from a dual shock system at open throttle to an attached shock at peak efficiency to a detached orientation at near stall. Steady three-dimensional Navier Stokes analysis reveals the dominant flow structures in the tip region in support of the ensemble averaged measurements. A tip leakage vortex is evident at all operating points as regions of low static pressure and appears in the same location as the vortex found in the numerical solution. An unsteadiness parameter was calculated to quantify the unsteadiness in the tip cascade plane. In general, regions of peak unsteadiness appear near shocks and in the area interpreted as the shock-tip leakage vortex interaction. Local peaks of unsteadiness appear in mid-passage downstream of the shock-vortex interaction. Flow field features not evident in the ensemble averaged data are examined via a Navier-Stokes solution obtained at the near stall operating point.


AIAA Journal ◽  
2008 ◽  
Vol 46 (5) ◽  
pp. 1025-1038 ◽  
Author(s):  
Ruolong Ma ◽  
William J. Devenport

1995 ◽  
Vol 117 (4) ◽  
pp. 522-532 ◽  
Author(s):  
W. C. Zierke ◽  
K. J. Farrell ◽  
W. A. Straka

A high-Reynolds-number pump (HIREP) facility has been used to acquire flow measurements in the rotor blade tip clearance region, with blade chord Reynolds numbers of 3,900,000 and 5,500,000. The initial experiment involved rotor blades with varying tip clearances, while a second experiment involved a more detailed investigation of a rotor blade row with a single tip clearance. The flow visualization on the blade surface and within the flow field indicate the existence of a trailing-edge separation vortex, a vortex that migrates radially upward along the trailing edge and then turns in the circumferential direction near the casing, moving in the opposite direction of blade rotation. Flow visualization also helps in establishing the trajectory of the tip leakage vortex core and shows the unsteadiness of the vortex. Detailed measurements show the effects of tip clearance size and downstream distance on the structure of the rotor tip leakage vortex. The character of the velocity profile along the vortex core changes from a jetlike profile to a wakelike profile as the tip clearance becomes smaller. Also, for small clearances, the presence and proximity of the casing endwall affects the roll-up, shape, dissipation, and unsteadiness of the tip leakage vortex. Measurements also show how much circulation is retained by the blade tip and how much is shed into the vortex, a vortex associated with high losses.


Author(s):  
Xi Nan ◽  
Feng Lin ◽  
Takehiro Himeno ◽  
Toshinori Watanabe

Casing boundary layer effectively places a limit on the pressure rise capability achievable by the compressor. The separation of the casing boundary layer not only produce flow loss but also closely related to the compressor rotating stall. The motivation of this paper is to present a viewpoint that the casing boundary layer should be paid attention to in parallel with other flow factors on rotating stall trigger. This paper illustrates the casing boundary layer behavior by displaying its separation phenomena with the presence of tip leakage vortex at different flow conditions. Skin friction lines and the corresponding absolute streamlines are used to demonstrate the three-dimensional flow patterns on and near the casing. The results depict a Saddle, a Node and several tufts of skin friction lines dividing the passage into four zones. The tip leakage vortex is enfolded within one of the zones by the separated flows. All the flows in each blade passage are confined within the passage as long as the compressor is stable. The casing boundary layer of a transonic compressor is also examined in the same way, which results in qualitatively similar zonal flows that enfolds the tip leakage vortex. This research develops a new way to study the casing boundary layer in rotating compressors. The results may provide a first-principle based explanation to stalling mechanisms for compressors that are casing sensitive.


2005 ◽  
Vol 128 (3) ◽  
pp. 421-429 ◽  
Author(s):  
Masahiro Murayama ◽  
Yoshiki Yoshida ◽  
Yoshinobu Tsujimoto

Tip leakage vortex cavitations originating from the tip clearance of an oscillating hydrofoil were observed experimentally. It was found that the delay between the unsteady and the steady-state results of the tip leakage vortex cavitation increase, and that the maximum cavity size decreases when the reduced oscillating frequency increases. To simulate the unsteady characteristics of tip leakage vortex cavitation, a simple calculation based on slender body approximation was conducted taking into account the effect of cavity growth. The calculation and experimental results of the cavity volume fluctuation were found to be in qualitative agreement.


Author(s):  
Desheng Zhang ◽  
Weidong Shi ◽  
Suqing Wu ◽  
Dazhi Pan ◽  
Peipei Shao ◽  
...  

In this paper, the tip leakage vortex (TLV) structures in an axial flow pump were investigated by numerical and experimental methods. Based on the comparisons of different blade tip clearance size (i.e., 0.5 mm, 1mm and 1.5mm) and different flow rate conditions, TLV trajectories were obtained by Swirling Strength method, and simulated by modified SST k-ω turbulence model with refined high-quality structured grids. A high-speed photography test was carried out to capture the tip leakage vortex cavitation in an axial flow pump with transparent casing. Numerical results were compared with the experimental leakage vortex trajectories, and a good agreement is presented. The detailed trajectories show that the start point of tip leakage vortex appears near the leading edge at small flow rate, and it moves from trailing edge to about 30% chord span at rated flow rate. At the larger flow rate condition, the starting point of TLV shifts to the middle of chord, and the direction of TLV moves parallel to the blade hydrofoil. As the increasing of the tip size, the start point of TLV trajectories moves to the central of chord and the minimum pressure in vortex core is gradually reduced.


Sign in / Sign up

Export Citation Format

Share Document