A241 The effects of linear accelerations on the maximum heat transport capacity of micro heat pipes with triangular grooves

2002 ◽  
Vol 2002 (0) ◽  
pp. 311-312
Author(s):  
Ahmad Jalilvand ◽  
Masafumi KATSUTA
1998 ◽  
Vol 120 (4) ◽  
pp. 1064-1071 ◽  
Author(s):  
J. M. Ha ◽  
G. P. Peterson

The original analytical model for predicting the maximum heat transport capacity in micro heat pipes, as developed by Cotter, has been re-evaluated in light of the currently available experimental data. As is the case for most models, the original model assumed a fixed evaporator region and while it yields trends that are consistent with the experimental results, it significantly overpredicts the maximum heat transport capacity. In an effort to provide a more accurate predictive tool, a semi-empirical correlation has been developed. This modified model incorporates the effects of the temporal intrusion of the evaporating region into the adiabatic section of the heat pipe, which occurs as the heat pipe approaches dryout conditions. In so doing, the current model provides a more realistic picture of the actual physical situation. In addition to incorporating these effects, Cotter’s original expression for the liquid flow shape factor has been modified. These modifications are then incorporated into the original model and the results compared with the available experimental data. The results of this comparison indicate that the new semiempirical model significantly improves the correlation between the experimental and predicted results and more accurately represents the actual physical behavior of these devices.


1996 ◽  
Vol 118 (3) ◽  
pp. 731-739 ◽  
Author(s):  
G. P. Peterson ◽  
H. B. Ma

A mathematical model for predicting the minimum meniscus radius and the maximum heat transport in triangular grooves is presented. In this model, a method for determining the theoretical minimum meniscus radius was developed and used to calculate the capillary heat transport limit based on the physical characteristics and geometry of the capillary grooves. A control volume technique was employed to determine the flow characteristics of the micro heat pipe, in an effort to incorporate the size and shape of the grooves and the effects of the frictional liquid–vapor interaction. In order to compare the heat transport and flow characteristics, a hydraulic diameter, which incorporated these effects, was defined and the resulting model was solved numerically. The results indicate that the heat transport capacity of micro heat pipes is strongly dependent on the apex channel angle of the liquid arteries, the contact angle of the liquid flow, the length of the heat pipe, the vapor flow velocity and characteristics, and the tilt angle. The analysis presented here provides a mechanism whereby the groove geometry can be optimized with respect to these parameters in order to obtain the maximum heat transport capacity for micro heat pipes utilizing axial grooves as the capillary structure.


2000 ◽  
Author(s):  
Zhiquan Yu ◽  
Nicholas A. Pohlman ◽  
Kevin P. Hallinan ◽  
Reza Kashani

Abstract An ion-drag pump is utilized to enhance the heat transport capacity of micro heat pipes. An analytical model is developed to estimate the maximum heat transport capacity as a function of the applied electric field. The model predicts that the application of an electric field causes a four fold increase in heat transport capacity. A transient analytical model was developed to permit variation of the electric field with applied thermal load. A proportional-integral-derivative controller was used to simulate active temperature control. The feasibility of achieving active temperature control was demonstrated experimentally.


1996 ◽  
Vol 118 (3) ◽  
pp. 740-746 ◽  
Author(s):  
H. B. Ma ◽  
G. P. Peterson

An experimental investigation was conducted and a test facility constructed to measure the capillary heat transport limit in small triangular grooves, similar to those used in micro heat pipes. Using methanol as the working fluid, the maximum heat transport and unit effective area heat transport were experimentally determined for ten grooved plates with varying groove widths, but identical apex angles. The experimental results indicate that there exists an optimum groove configuration, which maximizes the capillary pumping capacity while minimizing the combined effects of the capillary pumping pressure and the liquid viscous pressure losses. When compared with a previously developed analytical model, the experimental results indicate that the model can be used accurately to predict the heat transport capacity and maximum unit area heat transport when given the physical characteristics of the working fluid and the groove geometry, provided the proper heat flux distribution is known. The results of this investigation will assist in the development of micro heat pipes capable of operating at increased power levels with greater reliability.


RSC Advances ◽  
2015 ◽  
Vol 5 (34) ◽  
pp. 26716-26725 ◽  
Author(s):  
Jie Sheng Gan ◽  
Yew Mun Hung

The comparison of heat transport capacity and the thermal resistance as the performance indicators provides valuable insights into the underlying physical significance of the use of a nanofluid on the performance of micro heat pipes.


2018 ◽  
Vol 123 ◽  
pp. 181-190 ◽  
Author(s):  
Cem Ömür ◽  
A. Bilge Uygur ◽  
İlhami Horuz ◽  
H.Gürgüç Işık ◽  
Sadık Ayan ◽  
...  

2015 ◽  
Vol 137 (2) ◽  
Author(s):  
Matthew R. Pearson ◽  
Jamal Seyed-Yagoobi

Heat pipes are well known as simple and effective heat transport devices, utilizing two-phase flow and the capillary phenomenon to remove heat. However, the generation of capillary pressure requires a wicking structure and the overall heat transport capacity of the heat pipe is generally limited by the amount of capillary pressure generation that the wicking structure can achieve. Therefore, to increase the heat transport capacity, the capillary phenomenon must be either augmented or replaced by some other pumping technique. Electrohydrodynamic (EHD) conduction pumping can be readily used to pump a thin film of a dielectric liquid along a surface, using electrodes that are embedded into the surface. In this study, two two-phase heat transport devices are created. The first device transports the heat in a linear direction. The second device transports the heat in a radial direction from a central heat source. The radial pumping configuration provides several advantages. Most notably, the heat source is wetted with fresh liquid from all directions, thereby reducing the amount of distance that must be travelled by the working fluid. The power required to operate the EHD conduction pumps is a trivial amount relative to the heat that is transported.


Volume 3 ◽  
2004 ◽  
Author(s):  
R. Kempers ◽  
A. Robinson ◽  
C. Ching ◽  
D. Ewing

A study was performed to experimentally characterize the effect of fluid loading on the heat transport performance of wicked heat pipes. In particular, experiments were performed to characterize the performance of heat pipes with insufficient fluid to saturate the wick and excess fluid for a variety of orientations. It was found that excess working fluid in the heat pipe increased the thermal resistance of the heat pipe, but increased maximum heat flux through the pipe in a horizontal orientation. The thermal performance of the heat pipe was reduced when the amount of working fluid was less than required to saturate the wick, but the maximum heat flux through the heat pipe was significantly reduced at all orientations. It was also found in this case the performance of this heat pipe deteriorated once dry-out occurred.


2011 ◽  
Vol 15 (3) ◽  
pp. 879-888 ◽  
Author(s):  
Rathinasamy Senthilkumar ◽  
Subaiah Vaidyanathan ◽  
Sivaramanb Balasubramanian

This paper discuses the use of self rewetting fluids in the heat pipe. In conventional heat pipes, the working fluid used has a negative surface-tension gradient with temperature. It is an unfavourable one and it decreases the heat transport between the evaporator section and the condenser section. Self rewetting fluids are dilute aqueous alcoholic solutions which have the number of carbon atoms more than four. Unlike other common liquids, self-rewetting fluids have the property that the surface tension increases with temperature up to a certain limit. The experiments are conducted to improve the heat-transport capability and thermal efficiency of capillary assisted heat pipes with the self rewetting fluids like aqueous solutions of n-Butanol and n-Pentanol and its performance is compared with that of pure water. The n-Butanol and n-Pentanol are added to the pure water at a concentration of 0.001moles/lit to prepare the self rewetting fluids. The heat pipes are made up of copper container with a two-layered stainless steel wick consisting of mesh wrapped screen. The experimental results show that the maximum heat transport of the heat pipe is enhanced and the thermal resistances are considerably decreased than the traditional heat pipes filled with water. The fluids used exhibit an anomalous increase in the surface tension with increasing temperature.


Sign in / Sign up

Export Citation Format

Share Document