Integrated optical chip for high-resolution,single-resonance-mode x-ray monochromator system

2020 ◽  
Author(s):  
Ying-Yi Chang ◽  
Yi-Wei Tsai ◽  
Shih-Chang Weng ◽  
SHIH-LUN CHEN ◽  
Shih-Lin Chang
1996 ◽  
Vol 11 (4) ◽  
pp. 290-296
Author(s):  
I. C. Madsen ◽  
R. J. Hill ◽  
G. Stereff

A conventional vertical powder diffractometer has been adapted to allow the collection of high-resolution, single-wavelength diffraction data using Co, Cu or Mo radiation. The major modifications are (i) incorporation of an incident beam focusing monochromator attached to the tube shield, (ii) a variable tilt angle of the tube shield to provide a horizontal beam path through the diffractometer (for ease of alignment), (iii) mounting of the entire diffractometer on a single, very stable base-plate, with micrometer-controlled adjustment of the orientation, (iv) inclusion of a knife-edge, micrometer-controlled focusing slit, and (v) use of a range of Soller slits with acceptance angles down to 1.5° 2φ. The performance of the instrument compares favourably with conventional non-monochromated diffractometer data collected from SRM660 LaB6 and monoclinic ZrO2. In particular, the peaks are more symmetric and have narrower widths, and the peak-to-background ratio is much higher, leading to much superior resolution and profile shapes for structure solution and Rietveld refinement.


2013 ◽  
Vol 20 (6) ◽  
pp. 899-904 ◽  
Author(s):  
Atsushi Tokuhisa ◽  
Junya Arai ◽  
Yasumasa Joti ◽  
Yoshiyuki Ohno ◽  
Toyohisa Kameyama ◽  
...  

2011 ◽  
Vol 67 (2) ◽  
pp. 144-154 ◽  
Author(s):  
Marlena Gryl ◽  
Anna Krawczuk-Pantula ◽  
Katarzyna Stadnicka

High-resolution single-crystal X-ray diffraction measurements at 100 K were performed for the two polymorphs of urea–barbituric acid co-crystals: (I) P21/c and (II) Cc. Experimental and theoretical charge density and its properties were analysed for (I) and (II) in order to confirm the previous observation that in the polymorphs studied the barbituric acid molecules adopt different mesomeric forms, leading to different hydrogen-bond systems. Koch and Popelier criteria were applied to distinguish between hydrogen bonds and van der Waals interactions in the structures presented.


2018 ◽  
Vol 20 (4) ◽  
pp. 2724-2730 ◽  
Author(s):  
D. Koulentianos ◽  
R. Püttner ◽  
G. Goldsztejn ◽  
T. Marchenko ◽  
O. Travnikova ◽  
...  

The formation of double core hole pre-edge states of the form 1s−12p−1(1,3P)σ*,n for HCl, located on the binding energy scale as deep as 3 keV, has been investigated by means of a high resolution single channel electron spectroscopy technique recently developed for the hard X-ray region.


2014 ◽  
Vol 16 (24) ◽  
pp. 12228-12236 ◽  
Author(s):  
F. F. Porcher ◽  
M. Souhassou ◽  
C. E. P. Lecomte

High resolution single crystal X-ray diffraction is used to obtain the electron density and atomic charges in Na–X zeolite. The Coulomb potential and interaction energies are calculated for a given Na+ distribution and are discussed in connection with cation site affinities and adsorption of water molecules in the zeolite.


2020 ◽  
Vol 117 (26) ◽  
pp. 264101
Author(s):  
E. S. Dreier ◽  
A. Bergamaschi ◽  
G. K. Kallon ◽  
R. Brönnimann ◽  
U. L. Olsen ◽  
...  

2017 ◽  
Vol 7 (6) ◽  
pp. 584 ◽  
Author(s):  
Yuichi Inubushi ◽  
Ichiro Inoue ◽  
Jangwoo Kim ◽  
Akihiko Nishihara ◽  
Satoshi Matsuyama ◽  
...  

Optica ◽  
2015 ◽  
Vol 2 (10) ◽  
pp. 912 ◽  
Author(s):  
M. Makita ◽  
P. Karvinen ◽  
D. Zhu ◽  
P. N. Juranic ◽  
J. Grünert ◽  
...  

2016 ◽  
Author(s):  
William W. Zhang ◽  
Michael P. Biskach ◽  
Kai-Wing Chan ◽  
James R. Mazzarella ◽  
Ryan S. McClelland ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document