scholarly journals Effect of hearing aids on body balance function in non-reverberant condition: A posturographic study

PLoS ONE ◽  
2021 ◽  
Vol 16 (10) ◽  
pp. e0258590
Author(s):  
Chihiro Ninomiya ◽  
Harukazu Hiraumi ◽  
Kiyoshi Yonemoto ◽  
Hiroaki Sato

Objective The purpose of this study was to evaluate the effect of hearing aids on body balance function in a strictly controlled auditory environment. Methods We recorded the findings of 10 experienced hearing aid users and 10 normal-hearing participants. All the participants were assessed using posturography under eight conditions in an acoustically shielded non-reverberant room: (1) eyes open with sound stimuli, with and without foam rubber, (2) eyes closed with sound stimuli, with and without foam rubber, (3) eyes open without sound stimuli, with and without foam rubber, and (4) eyes closed without sound stimuli, with and without foam rubber. Results The auditory cue improved the total path area and sway velocity in both the hearing aid users and normal-hearing participants. The analysis of variance showed that the interaction among eye condition, sound condition, and between-group factor was significant in the maximum displacement of the center-of-pressure in the mediolateral axis (F [1, 18] = 6.19, p = 0.02). The maximum displacement of the center-of-pressure in the mediolateral axis improved with the auditory cues in the normal-hearing participants in the eyes closed condition (5.4 cm and 4.7 cm, p < 0.01). In the hearing aid users, this difference was not significant (5.9 cm and 5.7 cm, p = 0.45). The maximum displacement of the center-of-pressure in the anteroposterior axis improved in both the hearing aid users and the normal-hearing participants.

2020 ◽  
Vol 29 (3) ◽  
pp. 419-428
Author(s):  
Jasleen Singh ◽  
Karen A. Doherty

Purpose The aim of the study was to assess how the use of a mild-gain hearing aid can affect hearing handicap, motivation, and attitudes toward hearing aids for middle-age, normal-hearing adults who do and do not self-report trouble hearing in background noise. Method A total of 20 participants (45–60 years of age) with clinically normal-hearing thresholds (< 25 dB HL) were enrolled in this study. Ten self-reported difficulty hearing in background noise, and 10 did not self-report difficulty hearing in background noise. All participants were fit with mild-gain hearing aids, bilaterally, and were asked to wear them for 2 weeks. Hearing handicap, attitudes toward hearing aids and hearing loss, and motivation to address hearing problems were evaluated before and after participants wore the hearing aids. Participants were also asked if they would consider purchasing a hearing aid before and after 2 weeks of hearing aid use. Results After wearing the hearing aids for 2 weeks, hearing handicap scores decreased for the participants who self-reported difficulty hearing in background noise. No changes in hearing handicap scores were observed for the participants who did not self-report trouble hearing in background noise. The participants who self-reported difficulty hearing in background noise also reported greater personal distress from their hearing problems, were more motivated to address their hearing problems, and had higher levels of hearing handicap compared to the participants who did not self-report trouble hearing in background noise. Only 20% (2/10) of the participants who self-reported trouble hearing in background noise reported that they would consider purchasing a hearing aid after 2 weeks of hearing aid use. Conclusions The use of mild-gain hearing aids has the potential to reduce hearing handicap for normal-hearing, middle-age adults who self-report difficulty hearing in background noise. However, this may not be the most appropriate treatment option for their current hearing problems given that only 20% of these participants would consider purchasing a hearing aid after wearing hearing aids for 2 weeks.


1999 ◽  
Vol 8 (1) ◽  
pp. 40-46 ◽  
Author(s):  
Melisa R. Ellis ◽  
Michael K. Wynne

The loudness growth in 1/2-octave bands (LGOB) procedure has been shown previously to provide valid estimates of loudness growth for adults with normal hearing and those with hearing loss (Allen, Hall, & Jeng, 1990), and it has been widely incorporated into fitting strategies for adult hearing aid users by a hearing aid manufacturer. Here, we applied a simple modification of LGOB to children and adults with normal hearing and then compared the loudness growth functions (as obtained from end-point data) between the two age groups. In addition, reliability data obtained within a single session and between test sessions were compared between the two groups. Large differences were observed in the means between the two groups for the lower boundary values, the upper boundary values, and the range between boundaries both within and across all frequencies. The data obtained from children also had greater variance than the adult data. In addition, there was more variability in the data across test sessions for children. Many test-retest differences for children exceeded 10 dB. Adult test-retest differences were generally less than 10 dB. Although the LGOB with the modifications used in this study may be used to measure loudness growth in children, its poor reliability with this age group may limit its clinical use for children with hearing loss. Additional work is needed to explore whether loudness growth measures can be adapted successfully to children and whether these measures contribute worthwhile information for fitting hearing aids to children.


2010 ◽  
Vol 21 (10) ◽  
pp. 663-670 ◽  
Author(s):  
Jeffrey J. DiGiovanni ◽  
Ryan M. Pratt

Background: Accurate prescriptive gain results in a more accurate fit, lower return rate in hearing aids, and increased patient satisfaction. In situ threshold measurements can be used to determine required gain. The Widex Corporation uses an in situ threshold measurement strategy, called the Sensogram. Real-ear measurements determine if prescriptive gain targets have been achieved. Starkey Laboratories introduced an integrated real-ear measurement system in their hearing aids. Purpose: To determine whether the responses obtained using the Widex Sensogram were equivalent to those obtained using current clinical threshold measurement methods. To determine the accuracy of the Starkey IREMS™ (Integrated Real Ear Measurement System) in measuring RECD (real-ear to coupler difference) values compared to a dedicated real-ear measurement system. Research Design: A verification design was employed by comparing participant data measured from standard, benchmark equipment and procedures against new techniques offered by hearing-aid manufacturers. Study Sample: A total of 20 participants participated in this study. Ten participants with sensorineural hearing loss were recruited from the Ohio University Hearing, Speech, and Language Clinic participated in the first experiment. Ten participants with normal hearing were recruited from the student population at Ohio University participated in both experiments. The normal-hearing group had thresholds of 15 dB HL or better at the octave frequencies of 250–8000 Hz. The hearing-impaired group had thresholds of varying degrees and configurations with thresholds equal to or poorer than 25 dB HL three-frequency pure-tone average. Data Collection and Analysis: The order of measurement method for both experiments was counterbalanced. In Experiment 1, thresholds obtained via the Widex Sensogram were compared to thresholds obtained for each participant using a clinical audiometer and ER-3A insert ear phones. In Experiment 2, RECD values obtained via the Starkey IREMS were compared to RECD values obtained via the Audioscan Verifit™. A repeated-measures analysis of variance (ANOVA) was used for statistical analysis, and a Fisher's LSD (least significant difference) was used as a post hoc analysis tool. Results: A significant difference between Sensogram thresholds and conventional audiometric thresholds was found with the Sensogram method resulting in better threshold values at 0.5, 1.0, and 2.0 kHz for both groups. In Experiment 2, a significant difference between RECD values obtained by the Starkey IREMS and the Audioscan Verifit system was found with significant differences in RECD values found at 0.25, 0.5, 0.75, 1.5, 2.0, and 6.0 kHz. Conclusions: The Sensogram data differ significantly from traditional audiometry at several frequencies important for speech intelligibility. Real-ear measures are still required for verification of prescribed gain, however, calling into question any claims of shortened fitting time. The Starkey IREMS does perform real-ear measurements that vary significantly from benchmark equipment. These technologies represent a positive direction in prescribing accurate gain during hearing-aid fittings, but a stand-alone system is still the preferred method for real-ear measurements in hearing-aid fittings.


2021 ◽  
Vol 31 (Supplement_2) ◽  
Author(s):  
Margarida Ferreira ◽  
Cristina Mesquita ◽  
Paula Santos ◽  
João Borges ◽  
Maria Graça ◽  
...  

Abstract Background Ankylosing spondylitis (AS) is a chronic inflammatory rheumatic disease that leads to a limitation of mobility, which can cause postural deficits and progressive loss of balance. Aquatic exercise improves this health condition. The objetive is to verify the influence of an aquatic exercise program, on balance and functionality, in individuals with AS. Methods Pre-experimental study carried out on 6 individuals with AS. All individuals were assessed at baseline (M0) and 12 weeks after the intervention (M1) using the Bath indices (BASMI, BASFI and BASDAI) and the balance assessment protocol (‘Body Sway’) by the Physiosensing Platform. Data were analyzed using the Statistical Program Statistical Package for the Social Sciences (SPSS), version 26. Were used descriptive statistics and Wilcoxon test to compare M0 and M1. The significance value was 0.05. Results We verify improvements in BASMI (P = 0.046), BASFI (P = 0.042) and BASDAI (P = 0.027) scores. Through the analysis of the center of pressure variables, there were no statistically significant differences, between moments, in the protocol. However, when assessing balance, in the anteroposterior mean distance in both the protocol (eyes open) and in the protocol (eyes closed), in the root mean square in both protocols and in mediolateral mean velocity, only in the protocol (eyes open), there was a slight decrease in the median value. Conclusions The present study suggests that the specific aquatic exercise program, may influence balance and improve functionality in a population with AS. Therefore, the Bath indices translate improvements in the symptoms and functionalities of these participants.


2021 ◽  
Vol 4 (1) ◽  
pp. 013-022
Author(s):  
Blanchet Mariève ◽  
Prince François ◽  
Lemay Martin ◽  
Chouinard Sylvain ◽  
Messier Julie

We explored if adolescents with Gilles de la Tourette syndrome (GTS) had functional postural control impairments and how these deficits are linked to a disturbance in the processing and integration of sensory information. We evaluated the displacements of the center of pressure (COP) during maximal leaning in four directions (forward, backward, rightward, leftward) and under three sensory conditions (eyes open, eyes closed, eyes closed standing on foam). GTS adolescents showed deficits in postural stability and in lateral postural adjustments but they had similar maximal COP excursion than the control group. The postural performance of the GTS group was poorer in the eyes open condition (time to phase 1 onset, max-mean COP). Moreover, they displayed a poorer ability to maintain the maximum leaning position under the eyes open condition during mediolateral leaning tasks. By contrast, during forward leaning, they showed larger min-max ranges than control subjects while standing on the foam with the eyes closed. Together, these findings support the idea that GTS produces subclinical postural control deficits. Importantly, our results suggest that postural control disorders in GTS are highly sensitive to voluntary postural leaning tasks which have high demand for multimodal sensory integration.


2020 ◽  
Vol 5 (1) ◽  
pp. 36-39
Author(s):  
Mariya Yu. Boboshko ◽  
Irina P. Berdnikova ◽  
Natalya V. Maltzeva

Objectives -to determine the normative data of sentence speech intelligibility in a free sound field and to estimate the applicability of the Russian Matrix Sentence test (RuMatrix) for assessment of the hearing aid fitting benefit. Material and methods. 10 people with normal hearing and 28 users of hearing aids with moderate to severe sensorineural hearing loss were involved in the study. RuMatrix test both in quiet and in noise was performed in a free sound field. All patients filled in the COSI questionnaire. Results. The hearing impaired patients were divided into two subgroups: the 1st with high and the 2nd with low hearing aid benefit, according to the COSI questionnaire. In the 1st subgroup, the threshold for the sentence intelligibility in quiet was 34.9 ± 6.4 dB SPL, and in noise -3.3 ± 1.4 dB SNR, in the 2nd subgroup 41.7 ± 11.5 dB SPL and 0.15 ± 3.45 dB SNR, respectively. The significant difference between the data of both subgroups and the norm was registered (p


2018 ◽  
Vol 17 (4) ◽  
pp. 1144-1149 ◽  
Author(s):  
Shinichiro Morishita ◽  
Yuta Mitobe ◽  
Atsuhiro Tsubaki ◽  
Osamu Aoki ◽  
Jack B. Fu ◽  
...  

Older adults who have survived cancer experience significantly more falls compared with healthy adults. Adult cancer survivors may also have a lower balance function than healthy adults. We examined muscle strength and balance function among 19 cancer survivors and 14 healthy subjects. The mean age of the cancer survivors was 51.5 ± 11.2 years; 6 men and 13 women. Cancer diagnoses included breast cancer, retroperitoneal sarcoma, acute leukemia, lung cancer, colorectal cancer, thyroid cancer, Ewing’s sarcoma, and tongue cancer. The mean age of healthy subjects was 47.4 ± 14 years; 3 men, 11 women. Muscle strength was assessed using hand grip and knee extensor strength tests. Balance function was evaluated using the Timed Up and Go (TUG) test, and body sway was tested using a force platform. No significant differences were found with respect to right and left grip strength or right and left knee extension strength between the 2 groups. A significantly higher TUG time was observed in cancer survivors than in healthy subjects ( P < .05). With eyes open, the area of the center of pressure was significantly larger in cancer survivors than in healthy subjects ( P < .05). Similarly, the length per area was significantly lower both with eyes open and closed for cancer survivors than for healthy subjects ( P < .05). TUG was significantly correlated with muscle strength in both groups ( P < .05). However, no body sway parameters were related to muscle strength in either group. Cancer survivors had lower balance function that might not have been related to muscle strength. Cancer survivors should be evaluated for balance function as there is a potential for impairment. The findings of this study will be relevant for planning the prevention of falls for cancer survivors.


2011 ◽  
Vol 20 (4) ◽  
pp. 442-456 ◽  
Author(s):  
Zohreh Meshkati ◽  
Mehdi Namazizadeh ◽  
Mahyar Salavati ◽  
Masood Mazaheri

Context:Although reliability is a population-specific property, few studies have investigated the measurement error associated with force-platform parameters in athletic populations.Objective:To investigate the skill-related differences between athletes and nonathletes in reliability of center-of-pressure (COP) summary measures under eyes-open (EO) and eyes-closed (EC) conditions.Design:Test–retest reliability study.Setting:COP was recorded during double-leg quiet standing on a Kistler force platform before and after a fatiguing treadmill exercise, with EO and EC.Participants:31 male participants including 15 athletes practiced in karate and 16 nonathletes.Main Outcome Measures:Standard deviation (SD) of amplitude, phase-plane portrait, SD of velocity, mean total velocity, and area were calculated from 30-s COP data. Intraclass correlation coefficient (ICC), standard error of measurement, and coefficient of variation (CV) were used as estimates of reliability and precision.Results:Higher ICCs were found for COP measures in the athlete (compared with the nonathlete) group, postfatigued (compared with prefatigued) condition, and EC (compared with EO) tests. CVs smaller than 15% were obtained for most of the COP measures. SD of velocity in the anteroposterior direction showed the highest reliability in most conditions.Conclusions:Tests with EC and to a lesser extent tests performed in the athlete group and in the postfatigued condition showed better reliability.


1980 ◽  
Vol 45 (3) ◽  
pp. 415-422 ◽  
Author(s):  
Jeffrey L. Danhauer ◽  
Gordon W. Blood ◽  
Ingrid M. Blood ◽  
Nancy Gomez

This study determined whether professional and lay observers had similar impressions of preschoolers wearing hearing aids and if the size of the aid affected ratings. Stimuli consisted of three photographic slides of nine normally-hearing and speaking male preschoolers wearing (1) a body-type hearing aid, (2) a post-auricular type aid, and (3) no aid. Slides were accompanied by taped speech samples. Stimuli were presented to 75 professional and 75 lay observers who rated the children on a semantic differential scale containing 15 adjectives. Ratings were submitted to a factor analysis revealing Factor I as achievement and Factor II as appearance. Results of MANOVAs revealed that neither professional nor lay observers discriminated against the children on appearance regardless of the presence of a hearing aid, but that both groups rated them significantly poorer on achievement when an aid was present. Lay observers' ratings showed a bias against the size of the aid, while professionals exhibited negative impressions whenever an aid was present, regardless of its size. These findings indicate that the "hearing aid effect" was present on variables of achievement even for normal-hearing preschoolers.


Sports ◽  
2020 ◽  
Vol 8 (6) ◽  
pp. 89
Author(s):  
Albina Andreeva ◽  
Andrey Melnikov ◽  
Dmitry Skvortsov ◽  
Kadriya Akhmerova ◽  
Alexander Vavaev ◽  
...  

The effects of different factors—such as age, sex, performance level, and athletic shoe features—on postural balance in athletes remain unclear. The main objective of our study is to identify the features of postural stability in athletes of different age, sex, performance level, and using different types of athletic shoes. This study assessed postural stability in athletes (n = 936, 6–47 years) in a normal bipedal stance with eyes open (EO) and eyes closed (EC). Postural stability was evaluated based on the center of pressure (COP), sway area (AS), and velocity (VCP) while standing on a stabiloplatform. Children (6–12 years) and teen athletes (13–17 years) showed reduced AS-EO (p < 0.01) and VCP-EO (p < 0.01) compared to control (n = 225, 7–30 years). In male and female athletes aged 18+, only VCP-EC was lower versus control. In females (13–17 and 18+), VCP-EO and EC were lower than in males (p < 0.05). Only in the Shooting group, the athletes’ performance levels had an effect on VCP-EO (p = 0.020). Long use of rigid athletic shoes with stiff ankle support was associated with reduced posture stability. Postural stability in athletes was mostly influenced by the athlete‘s age, and, to a lesser extent, by their sex, performance level, and athlete shoe features.


Sign in / Sign up

Export Citation Format

Share Document